• Title/Summary/Keyword: lateral motion

검색결과 796건 처리시간 0.037초

기준모델 적응제어에 의한 유도 비행체의 자동조종장치 설계에 관한 연구 (Design of autopilot for a guided missile using model reference adaptive control)

  • 임호;박정일;김원규;박종국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.499-502
    • /
    • 1989
  • This paper is concerned with the stability analysis and the design of an auto pilot using direct model reference adaptive control for BTT missile with unknown dynamics when subjected to the longitudinal and lateral gusts. A motion of BTT missile can be separated into the longtudinal and lateral motione. The proposed algorithm is introduced different leakage terms about each motion into adaptation so as to prevent drift of the adaptive gain and alleviate gust effects and cross-coupling. The algorithm is applied to the 6DOF motion of an EMRAAT missile.

  • PDF

차량의 선회시 주행 안정성 강화를 위한 ESP 시스템 개발 및 성능 평가 (II) (Development and Evaluation of ESP Systems for Enhancement of Vehicle Stability during Cornering (II))

  • 송정훈
    • 대한기계학회논문집A
    • /
    • 제30권12호
    • /
    • pp.1551-1556
    • /
    • 2006
  • Two yaw motion control systems that improve a vehicle lateral stability are proposed in this study: a rear wheel steering yaw motion controller (SESP) and an enhanced rear wheel steering yaw motion controller (ESESP). A SESP controls the rear wheels, while an ESESP steers the rear wheels and front outer wheel to allow the yaw rate to track the reference yaw rate. A 15 degree-of-freedom vehicle model, simplified steering system model, and driver model are used to evaluate the proposed SESP and ESESP. A robust anti-lock braking system (ABS) controller is also designed and developed. The performance of the SESP and ESESP are evaluated under various road conditions and driving inputs. They reduce the slip angle when braking and steering inputs are applied simultaneously, thereby increasing the controllability and stability of the vehicle on slippery roads.

Activated Physical Properties at Air-Polymer Interface

  • Kajiyama, Tisato
    • Macromolecular Research
    • /
    • 제15권2호
    • /
    • pp.109-113
    • /
    • 2007
  • The surface molecular motion of monodisperse polystyrene (PS) films was examined using scanning vis-coelasticity microscopy (SVM) in conjunction with lateral force microscopy (LFM). The dynamic storage modulus, E', and loss tangent, $tan\delta$, at a PS film surface with number-average molecular weights, $M_n$, smaller than 30 k were found to be smaller and larger than those for the bulk sample, even at room temperature, meaning that the PS surface is in a glass-rubber transition or fully rubbery sate at this temperature when the $M_n$ is small. In order to quantitatively elucidate the dynamics of the molecular motion at the PS surface, SVM and LFM measurements were performed at various temperatures. The glass transition temperature, $T_g$, at the surface was found to be markedly lower than the bulk $T_g$, and this discrepancy between the surface and bulk became larger with decreasing $M_n$. Such an intensive activation of the thermal molecular motion at the PS surfaces can be explained in terms of an excess free volume in the vicinity of the film surface induced by the preferential segregation of the chain end groups.

정전부상체에 작용하는 횡방향 복원력 측정장치 (A Measurement Apparatus of Lateral Restoring Force Exerted on Electrostatically Suspended Object)

  • 전종업;박기태;박규열
    • 한국정밀공학회지
    • /
    • 제22권2호
    • /
    • pp.60-69
    • /
    • 2005
  • In electrostatic suspension system of thin plates like a silicon wafer or an aluminum disk for hard disk applications, the lateral restoring force exerted on a suspended object plays an important role since the lateral motion of the suspended object, owing to the inherently stable restoring forces, can be passively stabilized without any active control of it. This paper reports about the measurement apparatus of the lateral restoring force originating from a relative translation of the suspended object with respect to the electrodes-for-suspension. An approximate calculation of the lateral force in disk-shaped objects, the structure of the measurement apparatus, a measurement method, stabilization condition and the guideline in designing the measurement apparatus are described. Experimental results obtained by using a 3.5-inch aluminum disk as a suspended object are presented as well in order to assess the magnitude of lateral force and stiffness, and also verify the usefulness of the measurement apparatus.

전이형 외측 상완 피판술을 이용한 주관절 연부조직 결손의 피복 (Transposition Lateral Arm Flap for Coverage of the Elbow Defects)

  • 송주현;이윤민;이주엽
    • Archives of Reconstructive Microsurgery
    • /
    • 제17권2호
    • /
    • pp.82-86
    • /
    • 2008
  • Purpose: Soft tissue defect can occur on the posterior aspect of the elbow after trauma or fracture fixation. To cover the defect and maintain elbow functions, various flap surgeries including latissimus dorsi muscle flap, lateral arm flap and radial forearm flap can be performed. We present the clinical results of transposition lateral arm flap for coverage of the elbow defect and discuss the cause of posterior soft tissue necrosis after fracture fixation. Materials and Methods: Two patients who had posterior soft tissue defect of the elbow after open reduction of the fractures around the elbow were treated with transposition lateral arm flap. The mean size of skin defect was 20 $cm^2$. The flap was elevated with posterior radial collateral artery pedicle and transposed to the defect area. Donor defect was covered with split thickness skin graft. The elbow was immobilized for 1 week in extended position and active range of motion was permitted. Results: All two cases of transposition lateral arm flap survived without marginal necrosis. The average range of motion of the elbow was 10~115 degrees. Mayo elbow performance score was 72 and Korean DASH score was 23. Conclusion: When elbow fractures are fixed with three simultaneous plates and screws, skin necrosis can occur on the posterior aspect of the elbow around olecranon area. If the size of skin defect is relatively small, transposition lateral arm flap is very useful option for orthopaedic surgeons without microsurgical technique.

  • PDF

자기부상열차의 주행안정성 해석에 의한 횡 댐퍼 파라미터 연구 (A Parameter Study of Lateral Damper on Hunting Stability of Maglev Vehicle)

  • 한종부;김기정;김창현;한형석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.75-80
    • /
    • 2011
  • In the area of wheel on rail vehicle, hunting stability which is generated by lateral motion is one of important characteristics for running safety. It might cause not only oscillation of vehicle but also derailment in an unstable area of the high speed. A Maglev vehicle is usually controlled the voltage to maintain the air gap between electromagnet and track. However, in Maglev system, an occurrence possibility of hunting motion could be high, because Maglev vehicle is not controlled directly lateral force between electromagnet and track in the curved guideway. In this paper, running safety is evaluated when Maglev vehicle run on guideway at high speed according to installment of damper between maglev vehicles and bogies, and to analyze the effect of it. Also, the parametric study is carried out for selecting effective lateral damper properties through the simulation. To accurately predict the running safety, 3d multibody dynamics models which are included air spring, guideway conditions and irregularities profile are used. With the results acquired, suggestions were made whether to adopt the damper and how to optimize the damping characteristics.

  • PDF

견관절 운동면과 상완골 회전에 따른 견관절 가동범위의 차이 (Shoulder Range of Motion According to Sagittal, Coronal and Scapular Plane and Humeral Rotation)

  • 김용욱;차득영;이지용
    • 한국전문물리치료학회지
    • /
    • 제3권1호
    • /
    • pp.32-39
    • /
    • 1996
  • For effective rehabilitation of the shoulder, physical therapists must have correct knowledge of shoulder movements. The purpose of this study was to determine the relationship between shoulder movements and the rotation of the humerus in the sagittal, coronal and scapular planes. Fifty normal subjects(25 male, 25 female) were tested using a Dualar-plus digital goniometer and an air-splint. The subjects performed active shoulder elevation in each plane with the humerus rotated in both medial and lateral directions. The range of motion(ROM) of the glenohumeral joint was measured three times. The paired t-test was used to determine the difference in ROM between medial and lateral rotation of the humerus. Results showed that, in the sagittal and the coronal planes, there was a significant difference(p < 0.01) in ROM of the shoulder between medial rotation and lateral rotation which was greater. But in the scapular plane, there was no difference between medial and lateral rotation. Physical therapists should consider these results when the goal of treatment is to increase ROM of the shoulder.

  • PDF

초음파 모터용 람다형 다방향 변환자 (Multi-directionally Movable Lambda Shape Transducer for Ultrasonic Motor)

  • 도영수;남효덕;김영덕
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.131-136
    • /
    • 2008
  • The transducer for multi-directionally movable ultrasonic motor having lambda shaped vibrators has been proposed and designed. The two branches cross at a right angle with each other at the tip. FEM analyses of lambda shaped transducer were carried out to find vibration modes for ultrasonic motor. The lambda shaped transducer has one symmetric mode and two anti-symmetric modes. The symmetric mode generates the normal direction motion of the tip. The lateral and vertical direction motion of the tip are excited by two anti-symmetric modes. The normal and lateral direction motions made an lateral elliptic trajectory. And the normal and vertical direction motions made an vertical elliptic trajectory normal to previous one. The transducer with 1 mm in thickness and 25 mm in length has been fabricated and evaluated. The resonance frequencies of the transducer was 32 kHz and 103 kHz. The tangential and vertical vibration displacement of the transducer having the lateral elliptic trajectory were $1.5{\mu}m\;and\;1.1{\mu}m$, respectively at the driving voltage of 100 Vpp and frequency of 32 kHz and 103 kHz. And the tangential and vertical vibration displacement of the transducer having the vertical elliptic trajectory were $0.4{\mu}m\;and\;0.2{\mu}m$, respectively at the same driving condition.

In vivo 3-dimensional Kinematics of Cubitus Valgus after Non-united Lateral Humeral Condyle Fracture

  • Kim, Eugene;Park, Se-Jin;Lee, Ho-Seok;Park, Jai-Hyung;Park, Jong Kuen;Ha, Sang Hoon;Murase, Tsuyoshi;Sugamoto, Kazuomi
    • Clinics in Shoulder and Elbow
    • /
    • 제21권3호
    • /
    • pp.151-157
    • /
    • 2018
  • Background: Nonunion of lateral humeral condyle fracture causes cubitus valgus deformity. Although corrective osteotomy or osteosynthesis can be considered, there are controversies regarding its treatment. To evaluate elbow joint biomechanics in non-united lateral humeral condyle fractures, we analyzed the motion of elbow joint and pseudo-joint via in vivo three-dimensional (3D) kinematics, using 3D images obtained by computed tomography (CT) scan. Methods: Eight non-united lateral humeral condyle fractures with cubitus valgus and 8 normal elbows were evaluated in this study. CT scan was performed at 3 different elbow positions (full flexion, $90^{\circ}$ flexion and full extension). With bone surface model, 3D elbow motion was reconstructed. We calculated the axis of rotation in both the normal and non-united joints, as well as the rotational movement of the ulno-humeral joint and pseudo-joint of non-united lateral condyle in 3D space from full extension to full flexion. Results: Ulno-humeral joint moved to the varus on the coronal plane during flexion, $25.45^{\circ}$ in the non-united cubitus valgus group and $-2.03^{\circ}$ in normal group, with statistically significant difference. Moreover, it moved to rotate externally on the axial plane $-26.75^{\circ}$ in the non-united cubitus valgus group and $-3.09^{\circ}$ in the normal group, with statistical significance. Movement of the pseudo-joint of fragment of lateral condyle showed irregular pattern. Conclusions: The non-united cubitus valgus group moved to the varus with external rotation during elbow flexion. The pseudo-joint showed a diverse and irregular motion. In vivo 3D motion analysis for the non-united cubitus valgus could be helpful to evaluate its kinematics.

Lateral-torsional seismic behaviour of plan unsymmetric buildings

  • Tamizharasi, G.;Prasad, A. Meher;Murty, C.V.R.
    • Earthquakes and Structures
    • /
    • 제20권3호
    • /
    • pp.239-260
    • /
    • 2021
  • Torsional response of buildings is attributed to poor structural configurations in plan, which arises due to two factors - torsional eccentricity and torsional flexibility. Usually, building codes address effects due to the former. This study examines both of these effects. Buildings with torsional eccentricity (e.g., those with large eccentricity) and with torsional flexibility (those with torsional mode as a fundamental mode) demand large deformations of vertical elements resisting lateral loads, especially those along the building perimeter in plan. Lateral-torsional responses are studied of unsymmetrical buildings through elastic and inelastic analyses using idealised single-storey building models (with two degrees of freedom). Displacement demands on vertical elements distributed in plan are non-uniform and sensitive to characteristics of both structure and earthquake ground motion. Limits are proposed to mitigate lateral-torsional effects, which guides in proportioning vertical elements and restricts amplification of lateral displacement in them and to avoid torsional mode as the first mode. Nonlinear static and dynamic analyses of multi-storey buildings are used to validate the limits proposed.