• Title/Summary/Keyword: lateral current

Search Result 555, Processing Time 0.026 seconds

고강도 콘크리트 기둥의 거동에 미치는 콘크리트 강도와 띠철근의 영향 (Influence of Concrete Strength and Lateral Ties on Behavior of High-Strength Concrete Columns)

  • 이영호;정헌수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.245-253
    • /
    • 2002
  • This study was focused on the effect of concrete strength and lateral ties of concrete columns using high-strength concrete. Thirty-six concrete columns with 20cm square cross-section were tested. Experimental parameters included the concrete strength, the distribution of longitudinal bars and the volumetric ratio, yield strength, spacing of lateral ties. From the experiments, we found that: 1) the increasing rate of the strength and ductility of concrete columns caused by confinement of lateral ties was decreasing, as the concrete strength increased. 2) The high volumetric ratio and the reduction of tie spacing had a tendency to enhance the strength and improve the ductility. 3) The high-strength concrete columns required high volumetric ratio of lateral ties to maintain the proper strength and ductility. It was observed that the current AIK design code to specify the maximum tie spacing of high-strength concrete columns led to the poor strength and ductility for seismic design.

경골목구조에서 구조재와 오에스비로 구성된 못 접합부의 인발 및 전단성능 (Withdrawal and Lateral Resistance of Nail Joints Composed of Dimension Lumber and OSB in Light-Frame Wood Construction)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권3호
    • /
    • pp.211-220
    • /
    • 2013
  • 경골목조건축에서 못 접합부는 수평하중을 지지하고 전달하도록 설계되지만, 바람으로 인한 상향력처럼 인발하중에 직면하기도 한다. 본 연구에서는 경골목조건축에서 일반적으로 사용되는 구조재와 덮개로 구성된 못 접합부에 대하여 인발성능과 2면 전단시험을 통해 인발 및 측방하중에 대한 내력성능을 시험하고 설계기준에 부합되는 가를 평가하였다. 인발하중에 대한 내력성능은 부재의 비중에 의해 크게 좌우되었으며 I형장선의 경우 낮은 밀도에도 불구하고 높은 인발성능을 나타내었다. 최대 인발하중은 기준허용 최대 인발하중보다 매우 높게 나타났다. 전단성능도 비중이 큰 낙엽송과 오에스비로 구성된 접합부가 비중이 작은 SPF와 오에스비로 구성된 접합부보다 높은 성능을 나타내었으며 모두 기준설계치보다 높은 성능을 나타내었다. 접합부의 변형은 주로 못의 휨 변형에 의한 것으로 나타났으며 SPF와 오에스비로 구성된 접합부에서의 못의 휨 변형이 현저하게 나타났다.

급성 외측 상과염 치료를 위한 휴대용 미세전류자극기 개발 및 효과 검증 (Development and Evaluation of a Portable Micro-Current Stimulator for Acute Lateral Epicondylitis)

  • 권혁찬;이현주;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권2호
    • /
    • pp.68-74
    • /
    • 2019
  • Lateral epicondylitis is caused by repeated use of the wrist, which causes inflammation and pain in the wrist extensor and tendon of the humerus. Delayed onset muscle soreness (DOMS) caused by repetitive resistance exercise affects the tendons connected in series with the muscle, leading to lateral epicondylitis. Although micro-current stimulation has been suggested as a possible treatment for tendinitis, there are insufficient studies on specific variables such as frequency. In this study, 15 healthy adult males and females developed DOMS in the wrist extensor and tendon in the humerus. The experimental group consisted of a low frequency group applying 20 Hz and a high frequency group applying 100 Hz according to the micro-current frequency. Each subject underwent an experiment for 5 days after DOMS, and the recovery rates were compared by measuring AROM, GPT, MST, PPT, and VAS. As a result, the 20 Hz group showed significant changes in AROM, MST, and VAS compared to the control group on the 4th day, and the recovery rate was also higher than that of the 100 Hz group. On the 5th day, recovery rate of 100 Hz group was higher than 20 Hz in AROM and PPT, and MST showed higher recovery rate than 20 Hz group, but there was no significant difference. These results indicate that microcurrent stimulation is effective for the treatment of delayed myalgia and tendon inflammation and that the 100 Hz group has faster recovery than the 20 Hz group.

High Current Stress characteristics on Sequential Lateral Solidification (SLS) Poly-Si TFT

  • Jung, Kwan-Wook;Kim, Ung-Sik;Kang, Myoung-Ku;Choi, Pil-Mo;Lee, Su-Kyeong;Kim, Hyun-Jae;Kim, Chi-Woo;Jung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.673-674
    • /
    • 2003
  • The reliability of TFT, crystallized by sequential lateral solidification (SLS) technology, has been studied High current damage is characterized by high gate bias (-20V) and drain bias (-10V). It is found that performance of SLS TFTs is enhanced by high current stress up to 300 sec of stress time for 20/8 (W/L) N-TFT. After that, TFT performance is degraded with the increase of the stress time. It is speculated from the experimental data that SLS TFTs initially contain a number of unstable defect states. Then, the defect states seem to be cured by high current stress.

  • PDF

유한 요소법에 의한 편측식 선형유도전동기의 1차측과 2차측의 횡방향 편위에 따른 특성해석 (The Characteristic Analysis of a Single-Sided Linear Induction Motor due to the Lateral Displacement of the Primary and the Secondary by the F.E.M.)

  • 임달호;최창규;조철직;조윤현
    • 대한전기학회논문지
    • /
    • 제39권8호
    • /
    • pp.820-827
    • /
    • 1990
  • For the purpose of investigation the thrust force, the lateral force, and the eddy current loss when the primary and the secondary of a single-sided linear induction motor is displaced in the space, this paper proposes an analysis technique for the characteristics of the eddy current induced on the secondary and the magnetic flux density distribution in the y-z plane by F.E.M. To verify the effectiveness of this analysis technique, the starting-thrust force due to a lateral displacement is compared to the experimental data.

  • PDF

쌍곡선형 파랑모형을 이용한 해빈류 예측 (Prediction of Wave-Induced Current Using Time-Dependent Wave Model)

  • 김재중;이정만
    • 한국항만학회지
    • /
    • 제12권2호
    • /
    • pp.269-280
    • /
    • 1998
  • A Wave-induced current model is developed in our study and this model is composed with wave transform model and current model. Two types of wave model are used in our study one is Copeland(1985) type which is applied in the offshore region and the other is Watanabe and Maruyama(1984) type which is applied in the surf zone. The depth-integrated and time-averaged governing equation of an unsteady nonlinear form is used in the wave induced current model. Lateral mixing radiation stresses surface and bottom stresses are considered in our current model. Copeland’s(1976) is used as a surface friction formula. Numerical solutions are obtained by Leendertse scheme and compared with Noda’s(1974) experimental results for the uniform slope coastal region test and Nishimura & Naruyama’s (1985) experimental results and numerical simulation results for the detached breakwater. The results from our wave model and wave model and wave-induced current model show good agreements with the others and also show nonlinear effects around the detached breakwater. The model in this study can be applied in the surf zone considering the friction stresses.

  • PDF

A Study on Comparison between Center of Lateral Resistance and Pivot Point being Used in Handling Ships at the Present Time

  • Jeong, Tae-Gweon
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2012년도 추계학술대회
    • /
    • pp.160-161
    • /
    • 2012
  • The traditional theory regarding the pivot point of a ship during maneuvering, so called apparent pivot point, is located nearly at 1/3 ship's length from the bow when the ship is moving ahead, and between 1/4 ship's length from the stern and the rudder post when going astern. The pivot point is sometimes considered to be the centre of leverage for forces acting on the ship. However, the pivot point is located out of ship due to strong lateral force, such as current and it is very inconvenient to use during maneuvering a ship. In this paper firstly, pivot points due to ship's condition are investigated carefully. And then the center of lateral resistance used at the present are determined. While a new lateral force is added, we can compare the pivot point with the center of lateral forces. Finally, we will suggest the center of all lateral forces for maneuvering instead of pivot point. Especially, it will be very helpful for pilots to handle ships in simulation.

  • PDF

Electrical characteristics of lateral poly0silicon field emission triode using LOCOS process

  • Lee, Jae-Hoon;Lee, Myoung-Bok;Park, Dong-Il;Ham, Sung-Ho;Lee, Jong-Hyun;Lee, Jung-Hee
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제3권1호
    • /
    • pp.38-42
    • /
    • 1999
  • Using the LOCOS process, we have fabricated the lateral type polysilicon field emission triodes with poly-Si/oxide/Si structure and investigated their current-voltage characteristics for three biasing modes of operation. The fabricated devices exhibit excellent electrical performances such as a relatively low turn-on anode voltage of 14 V at VGC = 0V, a stable and high emission current of 92${\mu}$A/triode over 90 hours, a small gate leakage current of 0.23 ${\mu}$A/triode and an outstanding transconductance of 57${\mu}$S/5triodes at VGC = 5V and VAC = 26V. these superior electrical operation is believed to be due to a large field enhancement effect, which is related to the sharp cathode tips produced by the LOCOS process as well as the high aspect ratio (height /radius ) of the cathode tip end.

  • PDF

Controlling the lateral displacement of building with external lever by using of MR damper

  • Takin, Kambiz;Hashemi, Behrokh Hosseini;Nekooei, Masoud
    • Earthquakes and Structures
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2017
  • This article is all about using the MR damper with an external lever system for mitigation torsional and transitional lateral displacements by using of PID control algorithm. The torsional modes are so destructive and can be varied during an earthquake therefore, using a semi-active control system mostly recommended for them. In this paper the corner lateral displacement of each floor obtains and then it equivalents in a solid member and it connects to an MR damper, which relies to a rigid structure to reduce the response. An MR damper is a semi-active control system, which can absorb a lot of energy by injecting current to it. This amount of current is very low and needs low power supply, but it increases the amount of damper force, rather than inactive systems like viscous dampers. This paper will show the appropriate algorithm for current injection into MR damper when the eccentricity of the load is changed by using of Bouc-Wen and Bingham's methods and illustrates the coincidence of them.

Simulation of a Novel Lateral Trench Electrode IGBT with Improved Latch-up and Forward Blocking Characteristics

  • Kang, Ey-Goo;Moon, Seung-Hyun;Kim, Sangsig;Sung, Man-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제2권1호
    • /
    • pp.32-38
    • /
    • 2001
  • A new small sized Lateral Trench electrode Insulated Gate Bipolar Transistor(LTEIGBT) was proposed to improve the characteristics of conventional Lateral IGBT (LIGBT) and Lateral Trench gate IGBT (LTIGBT). The entire electrode of LTEIGBT was replace with trench-type electrode. The LTEIGBT was designed so that the width of device was no more than 19 ㎛. The Latch-up current densities of LIGBT, LTIGBT and the proposed LTEIGBT were 120A/㎠, 540A/㎠, and 1230A/㎠, respectively. The enhanced latch-up capability of the LTEIGBT was obtained through holes in the current directly reaching the cathode via the p+ cathode layer underneath n+ cathode layer. The forward blocking voltage of the LTEIGBT is 130V. Conventional LIGBT and LTIGBT of the same size were no more than 60V and 100V, respectively. Because the the proposed device was constructed of trench-type electrodes, the electric field moved toward trench-oxide layer, and punch through breakdown of LTEIGBT is occurred, lately.

  • PDF