Abstract
This article is all about using the MR damper with an external lever system for mitigation torsional and transitional lateral displacements by using of PID control algorithm. The torsional modes are so destructive and can be varied during an earthquake therefore, using a semi-active control system mostly recommended for them. In this paper the corner lateral displacement of each floor obtains and then it equivalents in a solid member and it connects to an MR damper, which relies to a rigid structure to reduce the response. An MR damper is a semi-active control system, which can absorb a lot of energy by injecting current to it. This amount of current is very low and needs low power supply, but it increases the amount of damper force, rather than inactive systems like viscous dampers. This paper will show the appropriate algorithm for current injection into MR damper when the eccentricity of the load is changed by using of Bouc-Wen and Bingham's methods and illustrates the coincidence of them.
Keywords
MR damper; semi-active control system; torsion; Bingham model; Bouc-Wen model;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Bahmani, P., van de Lindt, J. and Dao, T.N. (2014), "Displacement-based design of buildings with torsion: Theory and verification", J. Struct. Eng., ASCE, 140(6), 267-280.
2 Carlson, J. and Spencer, B. (1996), "Magnetorheological fluid dampers for semi-active control", Proceedings of the 3rd International Conference on Motion and Vibration Control, 3, 35-40.
3 Kamatchi P., Ramana G.V., Nagpal A.K., Iyer N.R. and Bhat J.A. (2015), "Dynamic to static eccentricity ratio for site-specific earthquakes", Earthq. Struct., 9(2), 391-413.   DOI
4 Kevadkar, M.D. and Kodag, P.B. (2013), "Lateral load analysis of R.C.C. building", Int. J. Modern Eng. Res., 3(3), 1428-1434.
5 Mousaad, A. (2013), "Vibration control of buildings using magnetorheological damper: A new control algorithm", J. Eng., Hindawi Publishing Corporation, doi: 10.1155/2013/596078.   DOI
6 Nigdeli, S.M. (2014), "Effect of feedback on PID controlled active structures under earthquake excitations", Earthq. Struct., 6(2), 1171-1186.
7 Serror, M.H., Diab, R.A. and Mourad, S.A. (2014), "Seismic force reduction factor for steel moment resisting frames with supplemental viscous dampers", Earthq. Struct., 7(6), 1171-1186.   DOI
8 Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1996), "Seismic response reduction using magnetorheological dampers", Proceedings of the IFAC World Congress, San Francisco, CA.
9 Ghasemi, M.R. and Barghi, E. (2012), "Estimation of inverse dynamic behavior of MR dampers using artificial and fuzzybased neural networks", Int. J. Optimiz. Civ. Eng., 2(3), 357-368.
10 Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1998), "An experimental study of MR dampers for seismic protection", Smart Mater. Struct., 7(5), 693-703.   DOI
11 Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1996), "Experimental verification of semi-active control strategies using acceleration feedback", Proceedings of 3rd International Conference on Motion and Vibration Control, 3, 291-296.
12 Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1996), "Modeling and control of magnetorheological dampers for seismic response reduction", Smart Mater. Struct., 5(5), 565-575.   DOI
13 Spencer, B., Dyke, S., Sain, M. and Carlson, J. (1997), "Phenomenological model for magnetorheological dampers", J. Eng. Mech., ASCE, 123(3), 230-238.   DOI
14 Spencer, B., Yang, G., Carlson, J. and Sain, M. (1998), "Smart dampers for seismic protection of structures: a full-scale study", Proceeding of the 2nd World Conference on Structural Control, Kyoto, Japan.
15 Yang, G. (2001), "Large-scale magnetorheological fluid damper for vibration mitigation: Modeling, testing and control", Ph.D. dissertation, University of Notre Dame.
16 Spencer, B., Yang, G., Carlson, J. and Sain, M. (2002), "Largescale MR fluid dampers: modeling and dynamic performance considerations", Eng. Struct., 24(3), 309-323.   DOI
17 Stathi, C.G., Bakas, N.P., Lagaros, N.D. and Papadrakakis, M. (2015), "Ratio of Torsion (ROT): An index for assessing the global induced torsion in plan irregular buildings", Earthq. Struct., 9(1), 145-171.   DOI
18 Tsang, H.H., Su, K. and Chandler, A. (2006), "Simplified inverse dynamics models for MR fluid dampers", Eng. Struct., 28(3), 327-341.   DOI
19 Zadeh, L.A. (1965), "Fuzzy sets", Inform. Control., 8(3), 338-353.   DOI