• Title/Summary/Keyword: laser-induced

Search Result 1,237, Processing Time 0.035 seconds

Effects of Laser Acupuncture Therapy According to the Wavelength at GB34·GB39 on Neuropathic Pain Rat Induced by Tibial and Sural Nerve Transection (양릉천(GB34)·현종(GB39)에 대한 파장대별 레이저침 시술이 동통에 미치는 영향)

  • Youn, Daehwan;Yoo, Pyungsik;Kim, Wangin;Kim, Mirea;Choi, Donghee;Na, Changsu
    • Korean Journal of Acupuncture
    • /
    • v.31 no.4
    • /
    • pp.195-207
    • /
    • 2014
  • Objectives : The purpose of this study is to examine the effects of laser acupuncture according to the wavelength(532 nm, 650 nm, 830 nm, 904 nm, and 1064 nm) at the acupoint of GB34 GB39 on neuropathic pain rat induced by tibial and sural nerve transection(TST). Methods : Neuropathic pain in rats was induced by tibial nerve and sural nerve transection. The rats were divided into the intact group, the TST control group, and the laser acupuncture therapy group. The laser acupuncture therapy groups were then divided into subgroups with 532 nm(L532), 650 nm(L650), 830 nm(L830), 904 nm(L904), and 1064 nm(L1064) laser acupuncture therapy. The acupoint of GB34 GB39 was selected, and laser acupuncture therapy was provided on both sides alternatively twice a week in a total of 6 sessions. Results : All the laser acupuncture groups showed a significant decrease in reaction time and force intensity. L532, L904, and L1064 groups showed a significant decrease in Bax, the L532 group showed a significant increase in Bcl-2, L532 and L1064 groups showed a significant decrease in the Bax/Bcl-2 ratio, and L532 and L650 groups showed a significant increase in mGluR5, as compared with the TST control group, among nerve tissue reaction. Conclusions : These results showed that laser acupuncture therapy at each of the wavelengths had some significance on neuropathic pain.

The Study on the Excitation Lasers for NO Planar Laser-Induced Fluorescence Imaging (NO PLIF용 excitation 레이저에 관한 연구)

  • Kang, Kyung-Tae
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.13-21
    • /
    • 1997
  • Excitations of eight pumping transitions for nitric oxide fluorescence imaging are analyzed under equivalent experimental conditions to determine the detection. Frequency mixed dye laser pumping, 1st anti-Stokes $H_2$ Raman of KrF excimer laser pumping and ArF excimer laser pumping show good sensitivities.

  • PDF

Planar Laser-Induced Fluorescence (PLIF) Measurements of a Pulsed Electrothermal Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.;Byungyou Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1808-1815
    • /
    • 2001
  • The characteristics of a pulsed plasma jet originating from an electrothermal capillary discharge have been investigate using laser-induced fluorescence (LIF) measurement. Previous emission measurements of a 3.1 kJ plasma jet show trial upstream of the Mach disk the temperature and electron number density are about 14,000 K and and 10$\^$17/ cm$\^$-3/, while downstream of the Mach dick tole values are about 25,000 K and 10$\^$18/ cm$\^$-3/, respectively. However, these values are barred on line-of-sight integrated measurements that may be misleading. Hence, LIF is being used to provide both spatially and temporally resolved measurements. Our recent work has been directed at using planar laser-induced fluorescence (PLIF) imaging of atomic copper in the plasma jet flow field. Copper is a good candidate for PLIF studies because it is present throughout the plasma and has electronic transitions that provide an excellent pump-detect strategy. Our PLIF results to date show that emission measurements may give a misleading picture of the flow field, as there appeals to be a large amount of relatively low temperature copper outside the barrel shock. which may lead to errors in temperature inferred from emission spectroscopy. In this paper, the copper LIF image is presented and at the moment, relative density of atomic copper, which is distributed in the upstream of the pulsed plasma jet, is discussed qualitatively.

  • PDF

A Study on the Effects of the Swirl Flow on the Distribution of Soot in the D.I. Diesel Engine (스월 유동이 직분식 디젤엔진 내의 Soot 분포에 미치는 영향에 관한 연구)

  • Lee, Gi-Hyeong;Jeong, Jae-U;Lee, Chang-Sik;Park, Hyeon-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.458-464
    • /
    • 2002
  • Recently, many researches have been performed to improve performances of the combustion and emission in the D.I.Diesel engine. Especially reduction of the soot formation in tole combustion chamber is the essential to acquire the improvement of the emission performance. These emission of the diesel combustion is effected by the characteristics of air-fuel mixing. Thus, in this study, the distribution of soot in the diesel combustion is measured by LII(laser induced incandescence) and LIS(Laser induced scattering) method. From this experimental results, it is confirmed that the swirl flow intensified by SCV(swirl control valve) is effective on the reduction of soot in the combustion chamber.

A Case of Therapeutic Laser for Suggested Drug Induced Liver Injury Patient during Treatment of Korean Medicine (한방치료 중 약인성 간손상으로 추정되는 환자에 대한 치료레이저 치험 1례)

  • Lim, Kyeong-Tae;Shin, Byung-Cheul;Hwang, Eui-Hyoung;Heo, In;Kim, Byung-Jun;Heo, Kwang-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.3
    • /
    • pp.183-189
    • /
    • 2016
  • A 84 year old male patient with amyotrophic lateral sclerosis (ALS) was treated by Jeungsonbaekchulsan and Gakbyeongyeonsu-tang for ten days. In the course of treatments, this patient was evaluated with Roussel Uclaf Casusality Assessment Method (RUCAM), showing results of drug induced liver injury. Herb medicine was immediately discontinued, followed by therapeutic laser treatments once a day for one week combined with 2 weeks of GODEX$^{(R)}$ administration. Transaminase results were lowered and changes in blood test results were time-effective changes. Therapeutic laser therapy could be considered effective on drug induced liver injury with further studies.

Laser-Induced Fluorescence Characterization for Real-Time Microplastic Counting (실시간 미세플라스틱 카운팅을 위한 레이저 유도 형광 특성 분석)

  • Ko, Seunghyeon;Oh, Geum-Yoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.149-154
    • /
    • 2022
  • In this paper, laser-induced fluorescence properties of four plastics were characterized through spectrometer analysis for real-time microplastic counting. Recently, environmental problems related to microplastics have emerged. In order to detect microplastics, analysis methods such as FT-IR and Raman are used. However, they have the disadvantages of being time-consuming and requiring a pretreatment process. In most plastic products on the market, 10% to 30% of plasticizers and reinforcing agents are added. Therefore, most microplastics present in seawater and freshwater emit fluorescence signals by 270 nm UV light source regardless of their type due to their molecular structure due to additives. Real-time microplastics counting is possible more easily by using the proposed laser-induced fluorescence detection method because of the fluorescence expression characteristic of 340 nm that appears due to the plasticizer of plastics.

Explosive mass-removal processes during high power nanosecond Nd-YAG laser ablation of silicon (나노초 야그 레이저 어블레이션에 의한 실리콘의 폭발적 제거 현상)

  • Jeong, S.H.;Yoo, J.H.;Grief, R.;Russo, R.E.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.736-742
    • /
    • 2000
  • Mass removed from crystalline silicon samples during high power single-pulse laser ablation was studied by measuring the resulting crater morphology with a white light interferometric microscope. The volume and depth of the craters show a strong nonlinear change as the laser irradiance increases across a threshold value, that is, approximately $2.2{\times}10^{10}\;W/cm^2$. Time-resolved shadowgraph images of the ablation plume show the ejection of large particulates from the sample for laser irradiance above the threshold, with a time delay of about 300-400 nsec. The thickness of superheated liquid layer near the critical temperature was numerically estimated, considering the transformation of liquid metal into liquid dielectric near the critical state (i.e., induced transparency). The estimated thickness of the superheated layer at a delay time of 200 nsec agreed with the measured crater depths, suggesting that induced transparency promotes the formation of a deep superheated liquid layer which leads to an explosive boiling responsible for the sudden increase of crater volume and depth.

  • PDF

Evaluation of Plasma Characteristics for Hg-Ar Using LIF (LIF를 이용한 Hg-Ar 플라즈마 특성 평가)

  • Moon, Jong-Dae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength. change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\to}6^3P_2$) were larger than 404.8nm ($6^3S_1{\to}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.