• Title/Summary/Keyword: laser metrology

Search Result 90, Processing Time 0.024 seconds

Transition of Femtosecond Laser Ablation Mechanism for Sodalime Glass Caused by Photoinduced Defects

  • Jeoung, Sae-Chae;Choi, Jun-Rye;Park, Myung-Il;Park, Mi-Ra;Choi, Dae-Sik
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.150-155
    • /
    • 2003
  • Femtosecond laser ablation mechanism was systematically investigated on sodalime glass in ambient conditions. The ablation crater diameter was measured for varying numbers of laser pulses as for varying well as the laser fluence. The analysis of the results with a one dimensional spatial Gaussian fluence distribution reveals that the inherent ablation mechanism has been altered from a multi-photon process to a single photon excitation due to defect sites that have been accumulated by successive laser pulses. Furthermore, the transition between the two regimes was found to be a function of both the laser fluence and the number of laser shots.

Femtosecond laser induced shock generation and its application (펨토초 레이저 유발 shock 형성 및 그 응용)

  • Jeoung, Sae Chae;Lee, Heung Soon;Sidhu, M.S.;Moon, Heh-Young
    • Laser Solutions
    • /
    • v.17 no.4
    • /
    • pp.1-6
    • /
    • 2014
  • Femtosecond laser induced shock generation in water and vitreous humor of enucleated porcine eyeball was investigated. When focusing the femtosecond laser into the liquid mediums, the acoustic waves with a frequency of about 15.6kHz could be observed by using wide-band microphone. The amplitude of the acoustic signals from water has attained a maximum under a laser power of about 5mW. Further increment of the power results in a decrement of the acoustic signals due to nonlinear optical process including filamentation of laser beam. We have further investigated the effect of femtosecond laser induced acoustic waves by applying the laser pulse into enucleated porcine eyeball. The comparative studies on both healthy and diseased eyeballs led us propose that the femtosecond laser pulses could be utilized as a novel tools for treatment of partially detached retina layers from their choroid structures.

  • PDF

Development of Laser Power Meter Calibration System with 12-diode Laser Sources (12개 다이오드 레이저를 활용하는 레이저 복사출력계 교정시스템 개발)

  • Kanghee Lee;Jae-Keun Yoo;In-Ho Bae;Seongchong Park;Dong-Hoon Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.2
    • /
    • pp.61-70
    • /
    • 2024
  • We demonstrate a laser power meter calibration system based on 12-diode laser sources coupled to single-mode fibres in a wavelength range from 400 to 1,600 nm. In our system, three laser power controllers ensure that the output power uncertainty of all laser sources is less than 0.1% (k=2). In addition, all laser beams are adjusted to have similar beam sizes of approximately 2 mm (1/e2-width) at the measurement position to minimise unmeasured laser power on a detector. As a reference detector, we use an integrating sphere combined with silicon and indium gallium arsenide photodiodes to minimise the non-uniformity and non-linearity of responsivity. The minimum uncertainty of the calibration system is estimated to be 1.1% (k=2) for most laser wavelengths.

A study on speckle size and measurable limitations in laser speckle interferometry method (레이저 스페클간섭법에 있어서 스페클크기와 측정 한계에 관한 연구)

  • 윤성운
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1996
  • The high coherence of laser beam has made it possible to observe interference effects even in the light scattered from rough surfaces. That's why, when object with a scattering surface is illuminated with laser light, we do see a speckled appearance due to random interference. This sort of unique property of laser speckle has bruht into existence the new noncontaciting techniques such as speckle metrology method of measuring deformation, displacement, and vibration etc of objects with high optical sensitivity. The measurable range of speckle metrology especially used to measure in -plane information, however, is limited by some factors, the so-called strain, rotation tilt of surface and out of displacement perpendicular to the plane of analysis This restrictions severly limits the measurable range of speckle metrology by causing the decorrelation of speckle patterns. It is the purpose of this paper to give a survey on the measurable limitation of speckle photography method that is one of speckle metrology. Namely we will discuss the mutual relationships and problems of each limitations adding the restriction on the largest and smallest displacement measurable with speckle methods.

  • PDF

Mode Selection and Amplification of an Optical Frequency Comb Using Femto-Second Laser Injection-locking Technique (펨토초 레이저 주입잠금법을 이용한 광주파수 빗의 모드 선택과 증폭)

  • Moon, H.S.;Kim, E.B.;Park, S.E.;Park, C.Y.
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.268-272
    • /
    • 2006
  • We have demonstrated the selection and the amplification of the components of an optical frequency comb using femto-second laser injection-locking technique. We used a mode-locked Ti:sapphire laser as a master laser and a single-mode diode laser as a slave laser. After passing through the interference filter with the center wavelength 794.7 nm and the transmittance bandwidth 1.5 nm, the optical frequency comb by mode-locked femto-second laser was injected into the slave laser. The injection-locked slave laser had $3{\sim}4$ multi-mode with the mode spacing 100.5 MHz, whichcorrespond to the repetition rate of a mode-locked Ti:sapphire laser. The power of the modes selected by femto-second laser injection-locking technique was amplified to several thousands times

Development of a Mid-infrared CW Optical Parametric Oscillator Based on Fan-out Grating MgO:PPLN Pumped at 1064 nm

  • Bae, In-Ho;Lim, Sun Do;Yoo, Jae-Keun;Lee, Dong-Hoon;Kim, Seung Kwan
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.33-39
    • /
    • 2019
  • We report development of a frequency-stabilized mid-infrared continuous-wave (cw) optical parametric oscillator (OPO) based on a fan-out grating MgO:PPLN crystal pumped at 1064 nm. The OPO resonator was designed as a pump-enhanced standing-wave cavity that resonates to the pump and signal beams. To realize stable operation of the OPO, we applied a modified Pound-Drever-Hall technique, which is a well-known method for powerful laser frequency stabilization. Tuning a poling period of the fan-out grating of the crystal allows wavelength-tunable OPO outputs from 1510 nm to 1852 nm and from 2500 nm to 3600 nm for signal and idler beams, respectively. At the idler wavelengths of 2500 nm, 3000 nm and 3500 nm, we achieved more than 50 mW of output powers at a pumping power of 1.1 W. The long-term stability of the OPO was confirmed by recording the power and wavelength variations of the idler for an hour.

Pitch Measurement of 150 nm 1D-grating Standards Using an Nano-metrological Atomic Force Microscope

  • Jonghan Jin;Ichiko Misumi;Satoshi Gonda;Tomizo Kurosawa
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.3
    • /
    • pp.19-25
    • /
    • 2004
  • Pitch measurements of 150 nm one-dimensional grating standards were carried out using a contact mode atomic force microscopy with a high resolution three-axis laser interferometer. This measurement technique was named as the 'nano-metrological AFM'. In the nano-metrological AFM, three laser interferometers were aligned precisely to the end of an AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$ stabilized He-Ne laser at a wavelength of 633 nm. Therefore, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM could be used to directly measure the length standard. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). The primary source of uncertainty in the pitch-measurements was derived from the repeatability of the pitch-measurements, and its value was about 0.186 nm. The average pitch value was 146.65 nm and the combined standard uncertainty was less than 0.262 nm. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

Mid-infrared Continuous-wave Optical Parametric Oscillator with a Fan-out Grating MgO:PPLN Operating Up to 5.3 ㎛

  • Bae, In-Ho;Yoo, Jae-Keun;Lim, Sun Do;Kim, Seung Kwan;Lee, Dong-Hoon
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.577-582
    • /
    • 2019
  • We report on a continuous-wave (cw) optical parametric oscillator (OPO) optimized for mid-infrared emission above 5.0 ㎛. The OPO is based on a magnesium-oxide-doped periodically poled LiNbO3(MgO:PPLN) crystal with a fan-out grating design. A linear two-mirror cavity resonating both at the pump and signal wavelengths is stabilized to the pump laser by using the modified Pound-Drever-Hall (PDH) method. The idler wavelength is continuously tunable from 4.7 ㎛ up to 5.3 ㎛ by varying the poling period of the fan-out grating crystal. Pumped by a diode-pumped solid state (DPSS) laser with a power of 1.1 W at 1064 nm, the maximum idler output power is measured to be 5.3 mW at 4.8 ㎛. The output power above 5.0 ㎛ is reduced to the hundreds of ㎼ level due to increased absorption in the crystal, but is stable and strong enough to be measured with a conventional detector.