• 제목/요약/키워드: laser measurement

검색결과 2,033건 처리시간 0.034초

자동차 차체 적용을 위한 레이저-아크 하이브리드 용접의 동축 모니터링 시스템 개발 (Development of Coaxial Monitoring System in Laser Arc Hybrid Welding for Automotive Body Application)

  • 박영환;이세헌;김철희
    • Journal of Welding and Joining
    • /
    • 제27권6호
    • /
    • pp.9-16
    • /
    • 2009
  • In this paper, the coaxial monitoring system to capture image of weld pool was developed in laser-arc hybrid welding. In order to obtain the reliable image, green laser was used as a illumination system and measuring components such as band pass filter, ND (Neutral Density) filter and shutter speed was designed and optimized. Using this monitoring system, weld pool images were captured according to laser power, welding speed, welding current and interspace between laser and arc through the experiment. ANOVA (Analysis of Variation) was carried out to identify the influence of process variables on bead widths extracted from captured images of monitoring system. Welding speed and current were major factor to affect weld pool.

Nd-YAG 펄스레이저에 의한 실리콘 가공시 발생하는 증발반동압력 측정 및 분석 (Measurement and analysis of recoil force during Nd-YAG laser ablation of silicon)

  • 이동준;정성호
    • 한국레이저가공학회지
    • /
    • 제6권3호
    • /
    • pp.11-17
    • /
    • 2003
  • Recoil force exerted on the substrate during a nanosecond laser ablation of silicon is measured. The ablation sample is placed at the end of a 400 $\mu\textrm{m}$ thick and 13 mm long silicon cantilever. The vibration amplitude of the cantilever induced by the recoil force is measured in real time with a probe beam. By comparing the deflection amplitude of the cantilever with a theoretical model, the recoil momentum is estimated. For laser irradiance in the order of 10$\^$11/ W/$\textrm{cm}^2$, the recoil pressure reached a value over 40${\times}$10$\^$9/ Pa.

  • PDF

레이저 기기의 국제표준 평가 방법 및 안전 관리 방안 연구 (Study on Safety Control of The Laser Equipment)

  • 박찬근;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.419-422
    • /
    • 2016
  • 최근 레이저 기술개발로 레이저 포인터, 레이저 수평계, 거리측정기, 온도계 등 다양한 레이저 제품들이 생산되고 있다. 다만 대부분의 소비자들은 그의 위험성에 대해서 인지하지 못하고, 무심코 사용한 레이저 용품에 의해 영구적 망막손상이나, 피부손상 등을 초래하고 있다. 이에 국내외 안전관리 현황 및 국제표준 IEC 60825-1 의 안전 요구사항 분석에 대한 연구이다.

  • PDF

평면 선해리 레이저유도 형광법과 레이래이 분산법을 이용한 연소실내의 OH 및 $O_2$의 2차원적 농도측정 (Two-dimensional $O_2$ and OH Density Measurement Using Tunable KrF Excimer Laser Light a Combustion Bomb via Planar Laser Induced Predissociative Fluorescence and Laser Rayleigh Scattering)

  • 김경수
    • 한국자동차공학회논문집
    • /
    • 제2권4호
    • /
    • pp.91-99
    • /
    • 1994
  • Tunable KrF Excimer Laser is used here for measuring OH and $O_2$ density distribustion in an open $H_2$/air premixed flame and in a combustion bomb. Laser Rayleigh Scattering(LRS) and Planar Laser Induced Predissociative Fluorescence(PLIPF) methods are used to obtain two-dimensional images of total and specific densities. Laser Excitation wavelengths are calibrated via flame images and combustion bomb images show good qualitative a greement with theoretical calculation. Furthermore images in a combustion bomb can be developed to study real Spark-Ignition engine combustions. Our experimental images show that there are no more collisional quenching problem at high pressure environment(including atmospheric pressure) using predissociative fluorescence technique. Further development to obtain two-dimensional temperature dustribution is ready to use eventhough it is not reported in this paper.

  • PDF

하니매화레이저를 이용한 여드름 흉터 치료 1례 (Case Study on Treating Acne Scar Using Hani-maehwa Laser)

  • 이득주;김철윤;권강;서형식
    • 한방안이비인후피부과학회지
    • /
    • 제29권2호
    • /
    • pp.106-111
    • /
    • 2016
  • Objective : The aim of this study is to report the effect of Hani-maehwa laser(fractional mode) treatment on acne scar. Methods : The patient with atrophic facial acne scars was treated with 5 sessions of laser therapy at 4-week intervals. The therapeutic response to treatment was assessed at 3 months after last laser session. The treatment effect was evaluated by standardized photography, anti aging, skin brightness and flatness. That was measured by micro fluorescence measurement camera(ECO SKIN, Cuvitz Inc.) in 16(left zygoma) and 26(right zygoma) spot. And side effects were also checked. Results : Atrophic facial acne scars have improved markedly. Anti aging, skin brightness and flatness were improved. Especially anti aging and flatness were noticeably improved. Adverse effects were not reported.Conclusions : Korean medicine cautery method applies to high level laser(CO2 Hani-maehwa laser). These are different designs but same principle. It can be considered that laser therapy is effective method for treating acne scars.

Target alignment method of inertial confinement fusion facility based on position estimation

  • Lin, Weiheng;Zhu, Jianqiang;Liu, Zhigang;Pang, Xiangyang;Zhou, Yang;Cui, Wenhui;Dong, Ziming
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3703-3716
    • /
    • 2022
  • Target alignment technology is one of the most critical technologies in laser fusion experiments and is an important technology related to the success of laser fusion experiments. In this study, by combining the open-loop and closed-loop errors of the target alignment, the Kalman state observer is used to estimate the position of the target, which improves the observation precision of the target alignment. Then the optimized result is used to guide the alignment of the target. This method can greatly optimize the target alignment error and reduce uncertainty. With the improvement of the target alignment precision, it will greatly improve the reliability and repeatability of the experiments' results, thereby improving the success rate of the experiments.

Novel velocity detection of moving object with rough surface vertically illuminated by self-mixing laser diode

  • Shibata, Takaaki;Shinohara, Shigenobu;Ikeda, Hiroaki;Yoshida, Hirofumi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.494-497
    • /
    • 1994
  • We propose a novel velocity detection method of moving object based on a speckle pattern on the target surface using a self-mixing laser diode (SMLD). By this measurement, it was confirmed that the speckle signal has its waveform independent of the target velocity, and has its averaged frequency directly proportional to the target velocity. So it will be possible to detect the velocity of the target transversely translating against the laser light beam using a compact measuring system.

  • PDF

Z-correction, a new method to improve TFT mask set overlay for TFT production yield enhancement

  • Ekberg, Peter;Sjostrom, Fredrik;Stiblert, Lars
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.598-601
    • /
    • 2005
  • Z-correction is new method to be used when measuring pattern registration of photomasks. The method is based on measurement of the plate profile in the Zaxis and takes into account the impact on the registration deviations caused by plate support, contamination as well as the photomask flatness itself. Z-correction further facilitates a more neutral way of judging the overlay properties between individual photomasks within a mask set.

  • PDF

온도보상형 온라인 굴절계를 이용한 해수의 염도 측정 (Salinity Determination Using Temperature Compensated On-Line Refractometer)

  • 최한욱;김영한
    • 한국항만학회지
    • /
    • 제15권1호
    • /
    • pp.99-105
    • /
    • 2001
  • An on-line refractrometer made of easily obtainable materials is built to determine the salinity and temperature of sea water, and its performance is examined by applying the refractometer to known salt solution. Since refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for accurate measurement. The outcome of salinity measurement for the different concentrations of salt solution indicates that the device is suitable for the salinity measurement by yielding stable and reproducible reading.

  • PDF

나노크기의 매연입자에 대한 LII의 열-물질 전달 모델에 관한 수치적 연구 (A Numerical Study of Heat and Mass Transfer Model of LII for Nanoscale Soot Particles)

  • 김규보;심재영;장영준;전충환
    • 대한기계학회논문집B
    • /
    • 제31권7호
    • /
    • pp.596-603
    • /
    • 2007
  • As increasing interest for soot emission. etc in combustion systems, various studies are being carried out for the reduction and measurement techniques of soot. Especially, laser induced incandescence is the useful measurement technique which has distinguished spatial and temporal resolution for primary particle size, volume fraction and aggregated particle size etc. Time resolved laser induced incandescence is the technique for measuring primary particle size that is decided to solve the signal decay rate which is related to the cooling behavior of heated particle by pulsed laser. The cooling behavior of heated particle is able to represent the heat and mass transfer model which are involved constants of soot property for surround gas temperature on the our previous work. In this study, it is applied to the time-dependence thermodynamic properties for soot temperature instead of constants of soot property for surround gas temperature and compared two different model results.