• Title/Summary/Keyword: laser measurement

Search Result 2,037, Processing Time 0.025 seconds

A Study on the Effect of O$_2$ annealing on Structural, Optical, and Electrical Characteristics of Undoped ZnO Thin Films Deposited by Magnetron Sputtering (산소 어닐링이 마그네 트론 스퍼터링으로 증착된 undoped ZnO박막의 구조적, 광학적, 전기적 특성에 미치는 영향에 대한 연구)

  • Yun, Eui-Jung;Park, Hyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.7
    • /
    • pp.7-14
    • /
    • 2009
  • In this paper, the effects of annealing conditions on the structural ((002) intensity, FWHM, d-spacing, grain size, (002) peak position), optical (UV peak, UV peak position) and electrical properties (carrier concentrations, resistivity, mobility) of ZnO films were investigated. ZnO films were deposited onto SiO$_2$/si substrates by RF magnetron sputtering from a ZnO target. The substrate was not heated during deposition. ZnO films were annealed in temperature ranges of $500\sim650^{\circ}C$ in the O$_2$ flow for 5$\sim$20 min. The film average thicknesses were in the range of 291 nm. The surface morphologies and structures of the samples were characterize by SEM and XRD, respectively. The optical properties were evaluated by photoluminescence (PL) measurement at room temperature (RT) using a He-Cd 325 nm laser. As the annealing temperature and time vary, the following relations were also observed: (1) proportional relationships among UV intensity (002) intensity, and grain size exist, (2) UV intensity is inversely proportional to FWHM, (3) there is no special relationship between UV intensity and electron carrier concentrations, (4) d-spacing is inversely proportional to (002) peak position, (5) UV peak position in the range of 3.20$\sim$3.24 eV means that ZnO films have a n-type conductivity which was consistent with that obtained from the electrical property, (6) the optimal conditions for the best optical and structural characteristics were found to be oxygen fraction, (O$_2$/(O$_2$+Ar)) of 0.2, RF power of 240W, substrate temperature of RT, annealing condition of 600$^{\circ}C$ for 20 min, and sputtering pressure of 20 mTorr.

Application Study of $CO_2$ Snow Cleaning for Cleaning of Foreign Matter and Corrosion Products on Iron Artifacts ($CO_2$ Snow Cleaning 적용 철제유물 표면 이물질 제거 연구)

  • Lee, Eun-Ji;Cho, Nam-Chul;Lee, Jong-Myong;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.333-344
    • /
    • 2011
  • Cleaning of foreign matter and corrosion products on surface among conservation treatment of iron artifacts is an important part for looking up a original form. The sand blaster is the most popular equipment when it removes the foreign matter and corrosion products on iron artifacts surface. Current foreign matter and corrosion products equipment, which mostly uses, is sand blaster. Glass dust which sprayed from sand blaster is harmful and causing environmental pollution. In order to solve these problems, we investigated the $CO_2$ snow cleaning that use a eco-friendly equipment to apply for cleaning foreign matter and corrosion products on surface of iron artifacts. It examined by using sand blaster and $CO_2$ snow cleaning to aged steel coupon and iron artifacts. In case of aged steel coupon, the result showed that the sand blaster and $CO_2$ snow cleaning methods were similar to the degrees of cleaning foreign matter and corrosion products, through surface roughness, color measurement and SEM. $CO_2$ snow cleaning applied to aged steel coupons weren't worn out the surface in comparison with sand blaster by SEM. When applied to the iron artifacts, power nozzle of the $CO_2$ snow cleaning was an excellent cleaning effect that surface wern't worn out in comparison with sand blaster. And, it showed that internal structure change of metal was no found before and after cleaning by X-ray radiography. Consequently, we confirmed that cleaning of the sand blaster and power nozzle of $CO_2$ snow cleaning were similar to the effect. But, it's very careful to use this method because of high outlet pressure of power nozzle for applying to the iron artifacts. As a result of experiments, it could be found that the cleaning methods should be selected depending on internal state of the artifacts.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system (치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교)

  • Lee, Wan-Sun;Park, Jong-Kyoung;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • Purpose: The purpose of this study was to assess the marginal and mesial fitness of zirconia single copings and 3-unit fixed partial dentures (FPDs) manufactured with an identical model. Materials and Methods: An epoxy model in which the maxillary right 2nd premolar is lost and maxillary 1st premolar and 2nd molar are formed as abutments was manufactured and scanned by using a laser scanner. A ten units of zirconia single copings were manufactured for maxillary 1st premolar and 2nd molar, respectively and the same number of 3-unit FPDs were manufactured. For the measurements of fitness, the manufactured silicone replicas were divided into four parts and the fitness were measured by digital microscope at measurement points (P1, P2, P3, P4 and P5) of each plane. The measured gaps were classified into three categories: marginal gap (MG, P1), axial gap (AG, average of P2 and P3), occlusal gap (OG, average of P4 and P5). Results: The ranges of MG, AG and OG for single copings were 18.47 - 40.54 ${\mu}m$, 39.73 - 73.61 ${\mu}m$ and 116.90 - 134.69 ${\mu}m$, respectively. The ranges of MG, AG and OG for 3-unit FPDs were 45.95 - 87.44 ${\mu}m$, 23.78 - 57.00 ${\mu}m$ and 99.89 - 131.06 ${\mu}m$, respectively. Conclusion: The result of the study shows that the MGs for 3-unit FPDs were higher than those of single copings, though they are within the range of clinical acceptance, indicating that the use of more homogeneous zirconia block and modification of sintering processes are needed to ensure the prevention of increase of gap in 3-unit FPDs.

A Study on the Cosmeceutical activities of Prunus Sargentii R. (산벚나무(Prunus sargentii R.) 수피의 화장품활성에 관한 연구)

  • Park, Jung-Mi;Lee, Jin-Young;Park, Tae-Soon;Hyun, Sok-Jun;Kim, Han-Hyuk;Cho, Young-Je;Kwon, O-Jun;Son, Ae-Ryang;Kim, Dong-Seok;An, Bong-Jeun
    • Applied Biological Chemistry
    • /
    • v.51 no.1
    • /
    • pp.70-78
    • /
    • 2008
  • Prunus sargentii R. of Rosaceae familiy, has been reported to have radical scavenging activity and anti-inflammatory effect. On these facts, biological activity and safety test were conducted to evaluate biological activities of the extracts of P. sargentii R. as a potential pharmaceutical ingredient. The electron donating ability of its ethanol extracts at a 500 ppm level showed 92%, which was higher than that of hot water extract (59%), the superoxide dismutase (SOD)-like activity of the water extract of P. sargentii R. was about 50%, the ethanol extract of P. sargentii R. was about 40% at 1,000 ppm concentration. Xanthine oxidase inhibition by the water extract of P. sargentii R. was about 40% and that by the ethanol extract was 60% respectively at 500 ppm concentration. From the measurement on lipid oxidation, the $Cu^{2+}$ chelating effect of the ethanol extract was higher than that of hot water extract. The $Fe^{2+}$ chelating effect was also shown to be about 80% at a 500 ppm concentration in both hot water extract and ethanol extract. The tyrosinase inhibition effect related to skin-whitening was 26% by hot water extract and 20% by ethanol extract respectively at a 1,000 ppm. Hyaluronidase inhibition activity related to the anti-inflammation effect was 96% in ethanolic extract at a 500 ppm. Clear zones formed by P. sargentii R. against the human skin-resident micro-flora such as Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli and Propionibacterium acnes indicated that antimicrobial activity of the ethanol extract was higher than that of the hot water extract.

Correlation between Corneal Ablation Amount and Intraocular Pressure after Corneal Refractive Surgery (각막굴절교정수술 후 각막절삭량과 안압변화의 상관관계)

  • Jung, Mi-A;Lee, Eun-Hee
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.543-551
    • /
    • 2018
  • Purpose : The purposes of this study were to evaluate the changes of intraocular pressure according to corneal ablation amount after corneal refractive surgery and the changes of intraocular pressure according to refractive errors before corneal refractive surgery. Methods : The mean age of adults who underwent LASIK corneal refractive surgery were $37.34{\pm}7.42years$, and 108 adults(48 males, 60 females) were participated in this study. Refractive errors, intraocular pressure, and corneal ablation amount were measured using an autorefractor, a noncontact tonometer, and an excimer laser. All test values were considered statistically significant when p<0.05. Results : The mean intraocular pressure before corneal refractive surgery was $15.08{\pm}2.60mmHg$ in males and $14.16{\pm}2.67mmHg$ in females. The decrease of intraocular pressure after corneal refractive surgery were 4.22mmHg in males and 3.61mmHg in females. Spherical equivalent power were $-3.89{\pm}2.17D$ in males and $-4.45{\pm}2.92D$ in females before corneal refractive surgery, and $-0.10{\pm}0.46D$ in males and $-0.04{\pm}0.46D$ in females after corneal refractive surgery. The corneal ablation amount after corneal refractive surgery were statistically significant, with $53.95{\mu}m$ in males and $61.26{\mu}m$ in females. There was significant correlation between corneal ablation amount and decrease of intaocluar pressure(r=0.2299, p<0.001). As the growth of corneal ablation amount in males, the decrease of intraocular pressure was significantly increased. As the growth of refractive error, the amount of decrease in intraocular pressure was also significant. The decrease of intraocualr pressure were $3.04{\pm}2.18mmHg$ in low refractive error, $4.10{\pm}2.16mmHg$ in middle refractive error, and $4.65{\pm}3.29mmHg$ in high refractive error. Conclusion : We found that intraocular pressure decreased after corneal refractive surgery by noncontact tonometer and the change of intraocular pressure which is an important index for glaucoma diagnosis, may affect the judgment of eye disease. We think that a preliminary questionnaire whether corneal refractive surgery is necessary for the measurement of intraocular pressure.

Chest CT Finding and Its Comparison with Bronchoscopic Finding in Endobronchial Tuberculosis (기관지결핵의 흉부전산화단층촬영소견 및 기관지경소견과의 비교)

  • Lee, Jae-Ho;Yoon, Hye-Kyung;Song, Jae-Woo;Yoo, Chul-Gyu;Chung, Hee-Soon;Kim, Young-Hwan;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.742-755
    • /
    • 1997
  • Background : Endobronchial tuberculosis(ET) is still relatively common disease in Korea. We intended to evaluate the length of endobronchial lesion, peribronchial thickness, luminal irregularity and associated mediastinal lymph node enlargement with Chest CT to get information for such aggressive treatment as electrocautery, laser therapy and so on of bronchial stricture in ET, and also to compare the change of Chest CT finding with that of bronchoscopic finding after one month of anti-tuberculosis treatment. Method : We performed CT in 26 patients who were diagnosed as ET by bronchoscopy at Boramae Hospital from November 1991 to March 1996. After classifying ET into seven subtypes according to bronchoscopic finding, we analyzed the CT finding of each subtype. And we followed up the bronchoscopy, CT, and PIT after one month of anti-tuberculosis treatment, and compared the change of CT findings with those of bronchoscopic findings in nine patients. Results : Age of the patients was from 17 to 73 years old, and the ratio of male to female was 1 : 25 with absolute female predominance. The site(s) of bronchial involvement by tuberculosis is one in 14 cases, two in nine cases and three in one case, respectively, and the left main bronchus was the most frequently involved site (13 cases for multiple involvements and 7 cases for single involvement among 26 cases). The length of bronchial involvement by tuberculosis which was measured by CT was from 10 to 55 mm, and there was a tendency that the length of involved lesion in fibrostenotic type was shorter than that of actively caseating type. Bronchial stricture on CT was noticed in 25 (96%) cases and the range of severity was from total occlusion to near-normal and also showed wide variation even though the subtype of ET was same. The increase of peribronchial thickness which was measured by CT, was noticed in 21 cases (91%) among 23 cases (in which the measurement was possible), and there was no improvement of peribronchial thickness in those cases which showed little improvement in bronchial stricture despite anti-tuberculosis treatment. There was no difference in the luminal irregularity of involved bronchi on CT in relation to bronchoscopic subtypes. The mediastinal lymph node enlargement, defined as the diameter of lymph node was larger than 1cm on CT, was detected in 20 cases (77%), and right side was more frequently involved (L : R = 1 : 5.2). The CT finding usually showed extrinsic bronchial compression but showed direct invasion in two cases which were bronchoscopically classified as tumorous type. When follow-up bronchoscopy and CT was performed after one month of anti-tuberculosis treatment in nine patients, CT showed significant improvement in peribronchial thickness and mediastinal lymph node enlargement. Bronchial stricture was also improved in 6 cases but aggravated in 3 cases despite anti-tuberculosis therapy. In two cases which were classified as fibrostenotic type by bronchoscopy, CT showed significant improvement in bronchial stricture, interestingly. Conclusion : We concluded that the role of Chest CT was complimentary to bronchoscopy in ET, since CT was useful in evaluating the length of bronchial involvement, peribronchial thickness, and mediastinal lymph node enlargement.

  • PDF