• 제목/요약/키워드: laser drilling

검색결과 126건 처리시간 0.033초

열적외선 기기와 3차원 레이저 스캐너를 이용한 암석 표면의 풍화강도 분석 (Analysis The Intensity of Weathering of The Rock Surface Using 3D Terrestrial Laser Scanner and Thermal Infrared Instrument)

  • 이수곤;조항교;쉬징
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1324-1333
    • /
    • 2010
  • This paper is used in a recent civil engineering field in three-dimensional laser-meter tiles using thermal imaging cameras for the weathered rock slopes precisely measured indirectly, to the degree that began in the will. In the field is difficult to access the degree of weathering of the rock slope to the existing direct way to compensate for the shortcomings of 3D Terrestrial Laser Scanner and weathering characteristics of rocks using thermal imaging cameras to get the information to analyze the degree of rock weathering is. Intensity of 3D TLS and the thermal camera with image analysis to analyze the degree of weathering of bedrock in the field of core drilling targeting indoor laboratory tests were analyzed through the study. Granite, gneiss, sandstone, much of the cancerous samples, each experiment has a 40 per category, each of which 30 were used to analyze the data collected. That degree of rock weathering, the rock, depending on the strength of the Intensity values can change, depending on the level of thermal imaging camera, also weathered the changes in temperature could see. Intensity is the strength of weak rocks, the more value decrease, the temperature of the thermal imaging camera through the swell Intensity and notice that the temperature had an inverse relationship. Intensity value of the low strength of weak rock, but the value came out of the rocks have been proved to be largely dependent on the contrast. The contrast of the surface rocks are weathered dark Intensity values lower temperature to swell the contrary, the degree of weathering can be distinguished.

  • PDF

재료변화에 따른 Micro-EDM에서의 가공성에 관한 연구 (A Study on the Machinability of the Micro-EDM Depending on the Materials)

  • 이상국;김태현;홍민성
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.658-665
    • /
    • 2012
  • Micro-EDM is widely used in metallic pattern, electronics, nuclear power and industry in the form of precision process. The improvement of Electro Discharge Machining has been on a steady progress since $19^{th}$ century. The technology has overcome the limits of the traditional precision process, enabling micro-EDM, micro electrolytic machining, micro drilling, micro punching and laser beam machining, which create versatile products with smaller sizes. What have been known about the major feature of Micro-EDM is high thermal energy so that their products are free from the hardness of their products as long as they are electrical conductor. However, each metal is suspected to have different features and natures even if they are created through the same procedure. In this thesis, the methodology of Micro-EDM and how to categorize them are explained. Also, the nature of the examined materials with surface shape and surface roughnes are analyzed. The results of the experiments are expected to understand surface roughness and workability of other materials for Micro-EDM.

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables

  • Lee, Su-Young;Piao, Chunmei;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kim, Tae-Hyung;Kim, Myung-Joo;Kwon, Ho-Beom;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.148-153
    • /
    • 2010
  • PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ${\geq}$ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

지상 레이저 스캐닝 자료를 이용한 터널단면관리시스템 개발 (Development of Cross Section Management System in Tunnel using Terrestrial Laser Scanning Data)

  • 노태호;김진수;이영도
    • 한국지리정보학회지
    • /
    • 제11권1호
    • /
    • pp.90-104
    • /
    • 2008
  • 높은 정확도와 고밀도의 자료를 제공하는 레이저 스캐닝 기술은 공간정보 분야를 포함한 여러 분야에서 폭 넓게 활용되고 있으며 특히, 레이저 스캐닝 기술의 개발은 건설공학분야에 있어서 방대한 정보 추출을 가능케 하여 그 활용성이 매우 높은 실정이다. 본 연구에서는 지상 레이저 스캐닝 기법에 의해 취득된 자료를 이용하여 보다 정확한 터널 내공단면을 결정하고, 이를 실무에서 활용할 수 있는 터널단면관리시스템을 개발한 결과, 다음과 같은 결론을 얻을 수 있었다. 지상 레이저 스캐너를 이용하여 고정밀도의 3차원 자료를 신속 정확하게 취득할 수 있었으며, 자료 처리 단계를 거쳐 0.1m, 0.5m, 1.0m 간격의 임의 단면을 신속히 결정할 수 있었다. 따라서 레이저 스캐닝 기법을 활용함으로써 각 단면의 여굴량과 미굴량 뿐만 아니라, 전체 터널 연장에서 발생한 여굴량과 미굴량을 신속하고 정확히 산정할 수 있었다. 또한, 터널 굴착단계에서 보다 정확한 여굴량과 미굴량을 산정하고, 이를 모니터링 할 수 있는 터널단면관리시스템을 개발하였다. 개발된 GUI 프로그램은 실무에서 더욱 효율적이고 경제적인 터널 굴착관리 및 모니터링을 가능하게 하며 향후, 임의 단면의 자료 추출로 터널 유지 관리에 대한 중요한 기반 자료의 제공 및 활용에 기여할 것으로 판단된다.

  • PDF

Step Pulse Shaping Technique for Nd:YAG Laser Using a Multi-Switching Method

  • Kwak, Su-Young;Park, Jin-Young;Kim, Su-Weon;Min, Byoung-dae;Chung, Hyun-ju;Kim, Hee-je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권2호
    • /
    • pp.55-59
    • /
    • 2004
  • Throughout manufacturing processes, pulse shaping is required for material processing and it is regarded as an important (actor according to the specific characteristics of materials. Therefore, this study suggests a highly appropriate pulse shaping technique using a multi-switching method. This is a pulse superposition method in which one flash lamp can consecutively turn on by the double switching of the discharging system. It is possible to construct a variety of pulse shapes and pulse widths by the consecutive trigger of the silicon-controlled rectifiers (SCR) of a PIC (program integrated circuit) one-chip microprocessor. The use of this technique can provide a number of advantages to people who require suitable pulse shaping for particular applications such as welding, cutting, and drilling.

버형성 최소화를 위한 스텝드릴 형상 개발 (Development of Step Drill Geometry for Burr Minimization)

  • 장재은;고성림
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.1043-1046
    • /
    • 2002
  • In this paper, drill tests were carried out by modifying drill geometry for burr minimization. Final objective of this study is to develop compatible drill shape for minimization of burr formation. These experimented results with modified drill are measured with laser sensor after performing drilling with variable material. Simultaneously, the cutting force and the torque of various drill geometry have been observed with same cutting condition to judge drill stability. As a result, burr was minimized in step drill with 75$^{\circ}$ step angle at every material.

  • PDF

굴착공 벽면거칠기 측정시스템(BKS-LRPS)의 혼탁도 보정에 관한 연구 (A Study on Turbidity Calibration of Borehole Roughness Measurement System (BKS-LRPS))

  • 박봉근;최용규;김명학;권오균;남문석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.1-10
    • /
    • 2009
  • Based on recent studies, the side resistance of rock socketed drilled shafts was affected by unconfined compressive strength of rock, socket roughness, rock types and joints, and initial normal stress. Especially, the socket roughness was affected by rock types and joints, drilling methods, and diameters of pile. In this study, a new roughness measurement system (BKS-LRPS, Backyoung-KyungSung Laser Roughness Profiling System) usable in water was developed. Based on the laboratory model tests, an EMD (Effective Measurement Distances) according to various turbidity was proposed as EMD=$1149.2{\times}T^{-0.64}_b$.

  • PDF

효율적인 버 형상 측정방법 개발 (Development of Effective Measurement Method for Burr Geometry)

  • 고성림;김원섭
    • 한국정밀공학회지
    • /
    • 제20권6호
    • /
    • pp.81-87
    • /
    • 2003
  • Triangulation method, conoscopic holography method and interferometry method are analyzed for effective measurement of micro burr geometry, which is formed in micro drilling. To select proper sensor, the cross section of a cylinder with 0.5mm diameter is measured and the result shows that conoscopic holography method is effective for measuring highly inclined surface in cylinder. Burrs with 1.0mm and 30${\mu}{\textrm}{m}$ height are measured by three suggested methods. As a result, the conoscopic holography method is proved to be most proper in measuring burr geometry. Burr measurement system is developed, which consists of conoscopic laser sensor, X-Y table, controller and burr measurement program. Burrs can be measured automatically and the result is displayed in 3D shape

수중에서 사용가능한 굴착공 벽면거칠기 측정 시스템(BKS-LRPS)의 굴착공 내 혼탁도 보정에 관한 연구 (Turbidity Calibration of Borehole Roughness Measurement System (BKS-LRPS) Usable in Water)

  • 박봉근;최용규;김명학;권오균;남문석
    • 한국지반공학회논문집
    • /
    • 제24권10호
    • /
    • pp.25-32
    • /
    • 2008
  • 암반에 근입된 현장타설말뚝의 주면마찰력은 암석의 일축압축강도 외에 굴착면의 거칠기, 암반의 재료특성, 초기 수직응력, 말뚝의 직경, 암반의 절리 및 풍화도 등에 크게 영향을 받는 것으로 알려져 있다. 특히 주면마찰력에 영향을 미치는 인자 중 굴착공의 거칠기는 암반의 종류, 말뚝의 직경, 그리고 말뚝의 시공법에 따른 영향이 큰 것으로 알려져 있다. 암반의 굴착공 벽면거칠기 측정장치인 Backyoung-Kyungsung Laser Roughness Profiling System(이하 BKS-LRPS라 칭함)의 혼탁도에 대한유효측정영역 및 측정 가능 여부를 결정하기 위하여 실내모형실험을 수행하였으며, 여기서 혼탁($T_b$)와 BKS-LRPS의 유효 측정거리(Effective Measurement Distances(EMD), mm)의 관계식은 $EMD=1149.2{\times}T_{b}^{-0.64}$로 구할 수 있었다.

고분자 중합체 심근 스템트를 이용한 기계적 경심근 혈류재건술의 혈관생성 반응 (Angiogenic Responce to Transmyocardial Mechanical Reveascularization(TMMR) with Polymer Myocardial Stent)

  • 최호;이철주;문광덕;김영진;강준규;홍준화;지경수;한만정;조상호
    • Journal of Chest Surgery
    • /
    • 제33권6호
    • /
    • pp.494-501
    • /
    • 2000
  • Background: Transmyocardial laser revascularization(TMLR) for revascularizing ischemic myocardium in patients was originally based on the assumption that laser channels remain their patency much longer. But recent studies show that laser channels did not remain open and that TMLR could achieve treatment benefits without long-term channel patency. The angiongencesis is currently thought to be induced by non-specific inflammatory response to mechanical tissue injury. This study is to evaluate hypothesis that various transmyocaridal mechanical revascularization(TMMR) may induce the angiogenic responses similar to that seen with TMLR, and transmyocaridal polymer stent revascularization(TMSR), the polymer stent in the myocardial tissue is hydrolyzed in 2 weeks, may enhance the non-specific inflammatory reaction resulting angiogenesis. Furthermore, polymer myocaridal stent channels remain long-term patency. Material and Method: Eight domestic pigs underwent ligation of the proximal circumflex artery, and 2 weeks later they were randomized to undergo transmycardial acupunctural revascularization (TMPR, Group I) of the left lateral wall with 18-G needle(n=2), to undergo transmyocardial (TMDR, Group II) with industrial 2mm steel drill(n=2), to undergo transmyocardial polymer stent revascularization (TMSR, Group III) after drilling the infarcted myocardium(n=2), the stent is poly(lactic acid-co-glycolic acid), which is self-degradated in the myocardium, and to a control group the ischemic zone was unterated(n=2). All the pigs were sacrificed after 4 weeks TMMR. Sections from the ischemic zone were submitted for vascular endothelial growth factor (VEGF) ELISA and histology. Result: There were makedly increase in the VEGF immunoassay in the ischemic zone of the TMMR group compared to the ischemic zone of the control group(control: each 30.85 and 43.15pg/mg protein, TMPR: each 44.14 and 68.61 pg/mg protein, TMDR: each 65.92 and 78.65 pg/mg protein, TMSR: each 177.39 and 168.87 pg/mg protein). TMSR channels caused greatest VEGF expression than channels made by other group and the polymer stent channels remained vacuole after 4 weeks. Conclusion: Transmyocardial polymer stent revascularization promoted the most angiogenci response by the VEGF immunoassay, although our study did not show the statistical significancy. The channels remained but the flow patency was not verified. Transmyocardial polymer stent revascularization (TMSR) is desirable in future experimental trials and in view of the significant cost implications comparable to that of laser.

  • PDF