• 제목/요약/키워드: laser device

검색결과 819건 처리시간 0.039초

Research of fast point cloud registration method in construction error analysis of hull blocks

  • Wang, Ji;Huo, Shilin;Liu, Yujun;Li, Rui;Liu, Zhongchi
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.605-616
    • /
    • 2020
  • The construction quality control of hull blocks is of great significance for shipbuilding. The total station device is predominantly employed in traditional applications, but suffers from long measurement time, high labor intensity and scarcity of data points. In this paper, the Terrestrial Laser Scanning (TLS) device is utilized to obtain an efficient and accurate comprehensive construction information of hull blocks. To address the registration problem which is the most important issue in comparing the measurement point cloud and the design model, an automatic registration approach is presented. Furthermore, to compare the data acquired by TLS device and sparse point sets obtained by total station device, a method for key point extraction is introduced. Experimental results indicate that the proposed approach is fast and accurate, and that applying TLS to control the construction quality of hull blocks is reliable and feasible.

High-Performance Optical Gating in Junction Device based on Vanadium Dioxide Thin Film Grown by Sol-Gel Method

  • Lee, Yong-Wook;Kim, Eung-Soo;Shin, Bo-Sung;Lee, Sang-Mae
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.784-788
    • /
    • 2012
  • In this paper, a high-performance optical gating in a junction device based on a vanadium dioxide dioxide ($VO_2$) thin film grown by a sol-gel method was experimentally demonstrated by directly illuminating the $VO_2$ film of the device with an infrared light at ~1554.6 nm. The threshold voltage of the fabricated device could be tuned by ~76.8 % at an illumination power of ~39.8 mW resulting in a tuning efficiency of ~1.930 %/mW, which was ~4.9 times as large as that obtained in the previous device fabricated using the $VO_2$ thin film deposited by a pulsed laser deposition method. The rising and falling times of the optical gating operation were measured as ~50 ms and ~200 ms, respectively, which were ~20 times as rapid as those obtained in the previous device.

레이저 구동 관내 가속장치 (LITA)의 성능에 대한 연구 (Performance of Laser-driven In-Tube Accelerator)

  • 김수겸;정인석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.39-42
    • /
    • 2003
  • We studied the vertical launch performance of the Laser-driven In-Tube Accelerator (LITA). This device is primarily characterized by accelerating a projectile in a tube. Owing to the confinement effect, the thrust performance is enhanced. The driver gas can be specified and its pressure be turned so that the impulse performance is optimized. In the experiments, a 3.0-gram projectile was vertically launched. The effects of the projectile exit condition, the laser beam incident direction and the driver gas species were experimentally studied.

  • PDF

Laser projection system that uses a 2D MEMS scanner

  • Seo, Jung-Hoon;Choi, Jung-Hwan;Kim, Yong-Ki;Yi, Jong-Kwon;Kwon, Jae-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.478-480
    • /
    • 2009
  • This experiment implemented a laser projection system that used the 2D MEMS scanner as the driving method for the display device. The 2D MEMS scanner, which can scan the images horizontally and vertically, was applied to drive the projection system using the interlaced scanning method. The laser was directly modulated to implement the grayscale and the images were WVGA resolution quality.

  • PDF

Development of laser thermal printing device

  • Park, Ill-Hyun;Kwon, Jin-Hyuk;Yi, Jong-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.919-921
    • /
    • 2007
  • A laser thermal printing system was developed to fabricate OLED. A single mode fiber laser beam was diffracted by an acousto-optic modulator. The diffracted beam was sent to a galvanometer to print organic film on ITO glass with resolution of $30\;{\mu}m$.

  • PDF

He-Ne 레이저에 대한 문헌과 이를 근거로 한 임상 활용 예의 비교 고찰 (An Analysis of the Correlation between He-Ne Laser Therapy in Literature and Clinical Application)

  • 윤인환;김남권
    • 한방안이비인후피부과학회지
    • /
    • 제19권2호
    • /
    • pp.192-201
    • /
    • 2006
  • Objectives : Recently, He-Ne laser has been used for clinical purpose. We study the medical basis of He-Ne laser therapy and We make a proposal concerning the clinical application of using He-Ne laser in Medicine. Methods : We have selected data related to He-Ne laser therapy and study how to use He-Ne laser in clinic. Results : In biology, He-Ne laser therapy has been effects of an improve in skin regeneration an improve in peripheral and central nerve regeneration an improve in muscle regeneration, an anti-inflammation an alleviation of pain and a bone repair. In oriental medicine, He-Ne laser has been used to laser acupuncture and laser oriental physical treatment. In clinic, He-Ne laser have been used to care several parts like as facial palsy, facial spasm, trigeminal neuropathy, rhinitis and tinnitus. Recently, there is argument that He-Ne laser therapy is suitable to medical insurance. Conclusions : Laser therapy in oriental medicine is widespread and We can apply He-Ne laser to facial palsy, facial spasm, trigeminal neuropathy, rhinitis, tinnitus by using laser acupuncture or laser oriental physical treatment. Till now the whole mechanisms are not fully understood, so we hope to study these mechanisms actively and make suitable to medical insurance device in the near future.

  • PDF

펨토초 레이저 펄스를 이용한 환원된 그래핀의 최소 선폭 패턴 구현에 관한 연구 (The study of optimal reduced-graphene oxide line patterning by using femtosecond laser pulse)

  • 정태인;김승철
    • 한국융합학회논문지
    • /
    • 제11권7호
    • /
    • pp.157-162
    • /
    • 2020
  • 최근 레이저를 이용하여 환원된 친환경 그래핀 패턴 기술(Laser Induced Graphene, LIG)은 간단하고 효율적으로 원하는 형태로 다양한 기판 위에 패터닝하는 것이 가능하여 신축 유연 전자 소자, 박막 형태의 에너지 저장 소자 등과 같이 새로운 친환경 전자 소자 제작에 많이 활용되고 있다. 이러한 그래핀 패턴 구조를 이용한 전자 소자의 성능과 효용성을 높이기 위해서는 그래핀 고유의 2차원 특성을 유지하면서 가능한 최소한의 선폭을 구현할 수 있는 최적화된 레이저 패터닝 조건에 대한 연구가 필수적이다. 본 논문에서는 최근 레이저 그래핀 패턴 연구에서 많이 사용되는 Ti:sapphire 펨토초 레이저를 이용해서 그래핀 광-열 산화반응을 분석하여 최적화된 그래핀의 최소선폭을 구현하였다. 레이저 에너지의 확산 효과를 최소화하기 위하여 레이저 광강도와 레이저 스캔 속도를 조절하여 최적의 그래핀 특성을 나타내는 패턴을 연구하였으며 18 ㎛의 집속된 빔을 이용하여 최소 30 ㎛의 이차원 그래핀 선폭을 구현하였다.

고속레이저추진원리를 활용한 무통증 주사기의 개발 및 의료산업으로의 Spin-off (Development of a painless injector using high speed laser propulsion and its spin-off to medical industry)

  • 한태희;여재익
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.326-330
    • /
    • 2010
  • 본 연구진은 레이저-물질 간의 상호작용을 응용하여 새로운 방식의 약물 전달 시스템을 개발하고 있다. 레이저 빔이 마이크로 단위 크기의 고무 챔버 속에 채워져 있는 액체 속에 집광되면 순간적인 고에너지 전달로 인해 기포가 생겨나고, 이로 인한 빠른 부피팽창으로 인해 마이크로 노즐 속의 약물 용액이 빠른 속도의 마이크로 젯의 형태로 분사되는 원리를 이용하는 것이다. 실험에서 노즐 출구의 지름은 125 ${\mu}m$, 측정된 마이크로 젯의 속도는 265 m/s였다. 이 장치의 주요한 특징은 시간에 따른 마이크로 젯의 제어가 가능하다는 것이다.

  • PDF

A Single Lens Micro-Angle Sensor

  • Saito, Yusuke;Gao, Wei;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.14-19
    • /
    • 2007
  • Angle sensors based on the principle of autocollimation, which are usually called autocollimators, can accurately measure small tilt angles of a light-reflecting flat surface. This paper describes a prototype micro-angle sensor that is based on the laser autocollimation technique. The new angle sensor is compact and consists of a laser diode as the light source and a quadrant photodiode as a position-sensing device. Because of its concise design, the microangle sensor facilitates dynamic measurements of the angular error motions of a precision stage without influencing the original dynamic properties of the stage. This is because the sensor only requires a small extra target mirror to be mounted on the stage. The sensitivity of the angle detection is independent of the focal length of the objective lens; therefore, an objective lens with a relatively short focal length is employed to reduce the size of the device. The micro-angle sensor uses a single lens for the both the laser collimation and focusing, which distinguishes it from the conventional laser autocollimation method that has separate collimate and objective lenses. The new micro-angle sensor has dimensions of $15.1\times22.0\times14.0mm$ and its resolution is better than 0.1 arc-second The optical design and performance of this micro-angle sensor were verified by experimental results.