• 제목/요약/키워드: laser dentistry

검색결과 571건 처리시간 0.03초

Nd:YAG레이저조사가 경화상아질에 미치는 영향에 관한 주사전자현미경적 연구 (A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Sclerotic Dentin)

  • 김문현;신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제24권4호
    • /
    • pp.397-410
    • /
    • 1999
  • In order to obtain the basic data concerning the optimal parameters in using Nd:YAG laser as a therapeutic modality to dentinal hypersensitivity, the author prepared 3 sections of sound dentin and 10 sections of sclerotic dentin with thickness of $0.5mm{\pm}0.1mm$ from human extracted teeth of anteriors and premolars, and applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, pulse duration $120{\mu}sec$, fiber diameter $320{\mu}m$) to surfaces of sound and sclerotic dentin sections for 1 second with contact/unidirectional moving mode of the fiber under speed of 3mm~4mm/sec and parameters of 0.5W/10Hz, 1.0W/10Hz, 1.5W/10Hz, 2.0W/10Hz: $62J/cm^2$, $124J/cm^2$, $187J/cm^2$, $249J/cm^2$. The author comparatively evaluated the characteristics of ultrastructural changes on surfaces of sound and sclerotic dentin sections irradiated by the pulsed Nd:YAG laser using the scanning electron microscopy. A fairly ill-defined bordered surface of partially closed and melted dentinal tubules can be seen on the scanning electron microscopic feature of the sound dentin surface irradiated by the pulsed Nd:YAG laser with energy density of $62J/cm^2$. The physical modification of sound dentin surface extensively occurred depended on the increase of energy density from $62J/cm^2$ to $124J/cm^2$, $187J/cm^2$, $249J/cm^2$. While, a fairly well-defined bordered surface of partially closed and melted dentinal tubules with thickened peritubular dentin can be seen on the scanning electron microscopic feature of the sclerotic dentin surface irradiated by the pulsed Nd:YAG laser with energy density of $62J/cm^2$. The physical modification of sclerotic dentin surface of a fairly rough, shallow depression with many cracks, thickened peritubular dentin and structureless dentinal tubules extensively occurred depended on the increase of energy density from $62J/cm^2$ to $124J/cm^2$, $187J/cm^2$, $249J/cm^2$ compared to those of sound dentin surface irradiated by the pulsed Nd:YAG laser under the same parameters. Therefore, it is recommended that the pulsed Nd:YAG laser as a therapeutic modality to dentinal hypersensitivity should be applied with the less energy density than $62J/cm^2$ on the sound dentin surface, and its energy density on the partially sclerotic dentin surface should be lower than that on the sound dentin surface to preserve tooth from unnecessary excessive structural destruction.

  • PDF

레이저 용접과 납착법으로 연결된 귀금속성 금속-도재 합금의 물리적 성질 (Mechanical Properties of Precious Metal-Ceramic Alloy Joined by the Laser-Welding and the Soldering Method)

  • 오정란;이석형;우이형
    • 구강회복응용과학지
    • /
    • 제19권4호
    • /
    • pp.269-279
    • /
    • 2003
  • This study investigated the mechanical properties of precious metal-ceramic alloy joined by the laser-welding and the soldering compared with the parent metal. Twenty-four tensile specimens were cast in precious metal-ceramic alloy and divided into three groups of eight. All specimens in the control group(group 1) were left in the as-cast condition. Group 2 and 3 were the test specimens, which were sectioned at the center. Eight of sectioned specimens were joined by soldering with a propane-oxygen torch, and the remaining specimens were joined by laser-welding. After joining, each joint diameter was measured, and then tested to tensile failure on an Instron machine. Failure loads were recorded, and then fracture stress(ultimate tensile strength), 0.2% yield strength and % elongation calculated. These data for three groups were subjected to a one-way analysis of variance(ANOVA). Neuman-Keuls post hoc test was then used to determine any significant differences between groups. The fracture locations, fracture surfaces were examined by SEM(scanning electron microscope). The results were as follows: 1) The tensile strength and 0.2% yield strength of the soldered group($280.28{\pm}49.35MPa$, $160.24{\pm}26.67MPa$) were significantly less than both the as-cast group($410.99{\pm}13.07MPa$, $217.82{\pm}17.99MPa$) and the laser-welded group($383.56{\pm}59.08MPa$, $217.18{\pm}12.96MPa$). 2) The tensile strength and 0.2% yield strength of the laser-welded group were about each 98%, 99.7% of the as-cast group. There were no statistically significant differences in these two groups(p<0.05). 3) The percentage elongations of the soldered group($3.94{\pm}2.32%$) and the laser-welded group($5.06{\pm}1.08%$) were significantly less than the as-cast group($14.25{\pm}4.05%$) (p<0.05). 4) The fracture of the soldered specimens occurred in the solder material and many porosities were showed at the fracture site. 5) The fracture of the laser-welded specimens occurred also in the welding area, and lack of fusion and a large void was observed at the center of the fracture surface. However, the laser-welded specimens showed a ductile failure mode like the as- cast specimens. The results of this study indicated that the tensile strengths of the laser-welded joints were comparable to those of the as-cast joints and superior to those of the soldered joints.

임상가를 위한 특집 4 - CAD/CAM 시스템을 이용한 가철성 보철 수복 (The removable prosthetic restorations utilizing CAD/CAM system)

  • 박지만;박은진;김성균;곽재영;허성주
    • 대한치과의사협회지
    • /
    • 제50권3호
    • /
    • pp.140-147
    • /
    • 2012
  • Recently, the digital solution of fabricating removable prosthesis by applying haptic input device, electronic surveying, and rapid prototyping was introduced. This review article covers the concept of electronic surveying, computer-aided denture framework designing procedure, discussions after several digital denture cases, directions of future development, such as digital tooth arrangement and RP flasking.

The effect of multiple application on microtensile bond strength of all-in-one dentin adhesive systems

  • Son, Sung-ae;Hur, Bock
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.567-567
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. The dentin surface of human molars, sectioned to remove the enamel from the occlusal surface were prepared. In group I, Scotchbond Multipurpose(SM, 3M ESPE) was applied by manufature's recommended. In group II, after the all-in-one adhesive, Adper Prompt L-Pop was applied for 15s, and light cured for 10s, the second coat was re-applied and light-cured.(omitted)

  • PDF

Surface structure characteristics of dental implants and their potential changes following installation: a literature review

  • Pitchaya Aneksomboonpol;Basel Mahardawi;Pheeradej Na Nan;Palawat Laoharungpisit;Thongnard Kumchai;Natthamet Wongsirichat;Napapa Aimjirakul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권3호
    • /
    • pp.114-124
    • /
    • 2023
  • Dental implants have been utilized for many years to treat individuals with missing teeth. To optimize the long-term success rate of such implants, new designs, surfaces, and materials have been analyzed. It is important for the clinician to have a background in the field of implant surface design, to be familiar with the strengths and limitations of the available options, and to be aware of the alterations in surface structure that may occur following installation. This article provides a detailed review of the structure and the surface characteristics of dental implants, the modifications of implant surface, as well as the methods of evaluating implant surface structure. Moreover, it provides information concerning the structural changes that may take place at the time of dental implant placement. It is important for clinicians to be aware of such changes to plan and execute implant procedures with the highest possible success and implant survival rates.

Enhancing the Antibacterial Effect of Erythrosine-Mediated Photodynamic Therapy with Ethylenediamine Tetraacetic Acid

  • MinKi Choi;Haeni Kim;Siyoung Lee;Juhyun Lee
    • 대한소아치과학회지
    • /
    • 제51권1호
    • /
    • pp.32-39
    • /
    • 2024
  • This study evaluated the additive impact of ethylenediamine tetraacetic acid (EDTA) on erythrosine-mediated photodynamic therapy (PDT) against Streptococcus mutans (S. mutans) biofilm by measuring colony-forming units and applying confocal laser scanning microscopy. Fifty-six bovine incisors, free from dental caries or structural defects, were utilized in this study. Dentin specimens were created by cutting with a low-speed diamond disk under a continuous flow of water, resulting in dimensions of 6.0 mm × 3.0 mm × 2.0 mm. The specimens were categorized into 4 groups: Control, EDTA, PDT, and EDTA + PDT. S. mutans ATCC 25175 was employed to establish biofilm on the dentin specimens. A 17% EDTA solution was applied for 1 min. For PDT, erythrosine served as the photosensitizer. Finally, a light-emitting diode source (385 - 515 nm) was employed in this study. The PDT group exhibited a significantly lower bacterial count than both the control and EDTA groups (p < 0.001). The EDTA + PDT group demonstrated a significantly reduced bacterial count compared to the other 3 groups (p < 0.001). This study demonstrated that EDTA enhances the antimicrobial efficacy of PDT on S. mutans biofilm. Even at a low concentration of photosensitizer, the combination of EDTA and PDT yields a significant antibacterial effect.

Pulsed Nd : YAG Laser 조사의 Streptococcus mutans에 대한 효과 (A Study on the Antibacterial Effects of Pulsed Nd: YAG Laser Irradiation to Streptococcus Mutans)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • 제22권1호
    • /
    • pp.15-22
    • /
    • 1997
  • In order to investigate the antibacterial effects of pulsed Nd:YAG Laser concerning to Streptococcus mutans, Streptococcus mutans was cultured and standardized and plated in 96 well plates. After that, black dye and chlorhexidine were applied and pulsed Nd:YAG Laser was irradiated to plates. Experimental groups which was applied with black dye and chlorhexidine were divided into 5 groups by concentration. And experimental groups and control group were subdivided as unlased and lased of 20, 40, and 60J. After laser irradiation, All groups were plated in agar plates and incubated for 18 hours. Bacterial colonies were counted and analysed comparitively, and the temperature of culture medium was measured on every laser irradiation. The results were obtained as follows; 1. In case of laser irradiation only, there is no significant reduction in number of Streptococcus mutans by irradiated energy of laser. 2. In case of black dye application, there is no difference by concentration of black dye but there is decrease when applied Laser and black dye simultaneously. 3. When applied chlorhexidine, the number of Streptococcus mutans was decreased according to increase of concentration, but there is no difference by irradiated energy of laser. 4. The temperature of culture medium was increased according to increase of irradiated energy of Laser, and the number of Streptococcus mutans was reduced remarkably just above 50 centigrade and killed above 70 centigrade. As above results, pulsed Nd:YAG Laser has well-absorbing affinity to black dye. And antibacterial effect of pulsed Nd:YAG Laser against Streptococcus mutans is seemed to be due to increase of temperature.

  • PDF

국소마취제에 함유된 에피네프린의 농도가 치수 및 치은 혈류에 미치는 영향 (The Influence of Epinephrine Concentration in Local Anesthetics on Pulpal and Gingival Blood Flows)

  • 이재상;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.475-484
    • /
    • 2003
  • 동통조절을 위해 국소마취제는 치과임상에서 광범위하게 사용되어진다. 가장 널리 쓰이는 국소마취제는 리도카인이고 이는 마취효과의 지속 및 지혈효과 등의 목적으로 혈관수축제를 포함하고 있다. 대표적 혈관수축제인 에피네프린은 임상에서 1:300,000에서부터 1:50,000의 농도로 다양하게 사용되어진다. 수복치료를 위해서는 통상적으로 1:100.000농도의 에피네프린이 사용되고 있고 외과적 근관치료시 지혈효과를 위해서는 1:50,000농도의 에피네프린이 추천되고 있다. 이들 농도의 에피네프린을 포함한 리도카인으로 국소마취시 에피네프린의 농도가 치수의 혈류 및 치은의 혈류에 미치는 영향을 이해할 필요가 있고 그 영향이 전기치수검사에 대한 치수의 반응성에 미치는 영향도 이해할 필요가 있다. 따라서 혈관수축제를 포함한 국소마취제에 의한 치수혈류의 변화와 치수신경의 반응성을 이해하는 것은 중요하다 하겠다. 본 연구의 목적은 두 가지 농도의 에피네프린을 포함한 국소마취제로 마취시 나타나는 치수 및 치은의 혈류 변화를 치수신경의 반응성과 비교, 관찰함으로써 국소마취제가 치수 및 치은에 미치는 영향을 파악하고자 함에 있다. 24세에서 27세까지의 10명의 피검자의 건전한 상악중절치를 시험에 이용하였다. Laser Doppler flowmeter의 probe을 고정하기 위한 splint를 간접법으로 인상용 putty를 이용하여 제작하고 치수 및 치은의 혈류량, 그리고 전기치수검사에 대한 반응성을 측정하기 위한 3개의 구멍을 만들었다. 피검자를 10분간 안정시킨 후 마취 전 10분간 정상 혈류량과 전기검사치를 측정하고 1:50,000 epinephrine과 1:100,00 epinephrine이 각각 함유된 2% 리도카인 용액 0.9 ml를 상악 좌측 중절치 치근단부위 협점막에 침윤마취하였다. 마취 후 70분간 치수 및 치은 혈류량을 laser Doppler flowmeter를 이용해 연속적으로 측정하여 그 수치를 컴퓨터에 저장하였고, 매 5분 간격으로 전기치수검사를 시행하여 그 측정치를 기록하였다. 매 시간 간격의 평균 혈류량을 정상 혈류량에 대한 백분율로 나타내고, 각각의 농도에서 최소 치수 및 치은 혈류량을 Paired t-test, Wilcoxon's signed rank test. Duncan's multiple range test. Fisher's exact test등을 이용. 통계분석 하여 다음과 같은 결과를 얻었다. 에피네프린이 함유되어 있지 않은 리도카인을 협점막에 주사시 혈류변화가 거의 나타나지 않았으나 1:50,000 및 1:100.000 에피네프린이 함유된 2% 리도카인을 협점막에 침윤마취시 치수 및 치은 혈류 공히 현저히 감소하였다(p<0.01). 1:50,000 에피네프린군은 1:100,000 에피네프린군에 비해 치수 혈류량이 현저히 억제되어 나타났으나(p<0.01), 치은 혈류량에서는 유의성 있는 차이를 나타내지 않았다(p>0.05). 두 농도의 에피네프린 군 공히 치은혈류는 치수혈류에 비해 유의하게 많은 감소를 나타내었다(p<0.05). 1:100,000 에피네프린 군에서 마취액 주입 후 치수혈류 최대감소가 가장 먼저 나타났고 이어서 전기검사에 대한 치수의 반응성 소실 및 치은혈류 최대 감소의 순으로 나타났다(p<0.05). 1:50,000 에피네프린군의 경우가 1:100,000 에피네프린군의 경우에 비해 마취지속시간이 길게 나타났으나 유의성은 없었다(p>0.05).