• 제목/요약/키워드: laser dentistry

검색결과 571건 처리시간 0.029초

백서에서 $CO_2$ 레이저를 이용한 치은절제술후 Aloe vera가 치유과정에 미치는 영향 (THE EFFECTS OF ALOE VERA ON WOUND HEALING OF $CO_2$ LASER-GINGIVECTOMY SITES IN WHITE RATS.)

  • 송원석;채중규;조규성;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제24권2호
    • /
    • pp.283-302
    • /
    • 1994
  • Gingivectomy has been utilized as a therapeutic method to remove diseased periodontal pocket wall in order to aid in root planing. Although chemical agents and electrosurgery has been used in addition to the conventional method of using surgical blades, difficulties in controling the depth of chemical penetration and effectively regenerating the gingival tissue as well as the slow wound healing has been pointed out as shortcomings of these methods. This study was designed to assess the effect of Aloe vera on wound healing of gingivectomy sites created by $CO_2$ laser on palatal gingiva of maxillary molar region of white rats. Those sites treated by surgical blades were designated as control, by $CO_2$ laser as Experimental group I, by surgical blades in addition to topical application of Aloe vera as Experimental group II, and by $CO_2$ laser and Aloe vera application as Experimental group III. Animals were sacrificed at 2 days, 3 days, 1 week, 2 weeks and 3 weeks postoperatively, and the specimens were histologically analyzed. The results were as follows : 1. Resorption of blood clots were observed in the control at 3rd day, followed by the rest of the experimental groups at 1 week postoperatively. 2. Persistent inflammation was observed up to 1 week in the control and Experimental group II and III, and until the 2nd week in Experimental group I. 3. Granulation tissue was observed up to 1 week in the control, and 2 weeks in the rest of the groups. 4. Epithelization started on the 2nd day. The control showed the most rapid epithelization, and the process was completed by the 2nd week in all groups. 5. Experimental group II and III, which were treated with Aloe vera, showed similar healing patterns to the control and Experimental group I.

  • PDF

Evaluation and comparison of the marginal adaptation of two different substructure materials

  • Karaman, Tahir;Ulku, Sabiha Zelal;Zengingul, Ali Ihsan;Guven, Sedat;Eratilla, Veysel;Sumer, Ebru
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.257-263
    • /
    • 2015
  • PURPOSE. In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. MATERIALS AND METHODS. Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and two-way variance analysis was used for more than two data sets. Pearson's correlation analysis was also performed to assess relationships between variables. RESULTS. According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, $24.47{\pm}5.82{\mu}m$ before and $35.11{\pm}6.52{\mu}m$ after cementation; in the laser-sintered Co-Cr structure, it was, on average, $60.45{\pm}8.87{\mu}m$ before and $69.33{\pm}9.03{\mu}m$ after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. CONCLUSION. Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings.

치과 SLM용 Ni-Cr 금속분말 특성 관찰 (Production of Ni-Cr Metal Powder by Selective Laser Melting for Dentistry to Observation of Characteristics)

  • 홍민호
    • 대한치과기공학회지
    • /
    • 제37권1호
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: The selective laser melting (SLM) process for dentistry, which is one of the additive manufacturing technologies (AM) allows for rapid production of a three-dimensional model with complex shape by directly melting metal powder. This process generates detailed items of a three-dimensional model shape through consolidation of a thin powder layer by utilizing both selective melting and laser beam simultaneously. In regard to SLM process, Fe-base powder, Ti-6AI-4V powder, AI-base powder, etc. have been researched. It is believed that the aforementioned technologies will be widely utilized in manufacturing metal parts using metal powder of raw material. This study chose Ni-Cr-Mo metal powder in order to manufacture metal powder materials that would be used in the selective laser melting for dentistry. Methods: This study manufactured metal powder using mechanical alloying technique (MA) among those metal powder manufacturing techniques. Moreover, this study aimed to utilize the metal powder manufactured after observing the characteristics of powder as preliminary data of Ni-Cr-Mo metal powder. This study could obtain the following conclusions within the experimental limitations. Results: As a result of mechanically alloying Ni-Cr-Mo powder over time, its mean particle size was $66.93{\mu}m$ $54.4{\mu}m$ and $45.39{\mu}m$ at 10h, 20h and 30h, respectively. The gtain form of metal powder by mechanical alloying technique was a sponge-like shape of irregular plate; however, the gtain form manufactured by high-pressure water aromization process had the following three types: globular type, chain type and oval type. Conclusion: This study found $37.65{\mu}m$ as the mean particle size of Ni-Cr-Mo metal powder, which was manufactured using water atomization technique under the following conditions: water atomization flux of 300 liter/min, hydraulic pressure of $400kgf/cm^2$ and injection angle of $45^{\circ}$. This study confirmed that the grain form of powder (solid particle form) would vary depending on the manufacturing process.

Nd : YAG레이저 조사시(照射時) 치아(齒牙) 법랑질(琺瑯質)의 변화(變化) 및 접착력(接着力)에 관(關)한 연구(硏究) (A STUDY ON THE EFFECT OF PULSED Nd : YAG LASER IMPACTS TO THE ENAMEL SURFACE AND BOND STRENGTH WITH COMPOSITE RESIN)

  • 박종만;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.85-101
    • /
    • 1991
  • The purpose of this study was to determine the optimum range of laser energy density to the enamel surface of permanent incisors when they are irradiated with the pulsed Nd : YAG laser, Laser impacts on each experimental group were made at energy density of $20\sim50J/cm^2$ by 20 pulses of the pulse width 1.2 msec. The author investigated the enamel surface with the sunning electron microscope(SEM) and the surface roughness tester, and measured the shear bond strength between electrolytically etched Ni-Cr-Be alloy casting and composite resin. The obtained results were as follows: 1. The surface roughness of enamel after laser irradiation showed the significant difference level from the energy density $40J/cm^2(P<0.05)$. 2. The mean shear bond strength of etched-metal resin-bonded specimens were $154.23{\pm}33.30kg/cm^2$ at unlased enamel surface and $195.72{\pm}29.56kg/cm^2$ at lased energy density $30J/cm^2$, and showed a significant difference(P<0.05). 8. SEM photographs showed the irregular microcracks and the structural changes of lased enamel surface. 4. SEM photographs of the fracture surface after testing the shear bond strength showed the aspect of interfacial fracture between bonding agent and composite resin at the metal sides.

  • PDF

Esthetic treatment of gingival melanin hyperpigmentation with a Nd:YAG laser and high speed rotary instrument: comparative case report

  • Ko, Hyuk-Jin;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • 제40권4호
    • /
    • pp.201-205
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the clinical effectiveness of and patient's satisfaction with treatment of gingival melanin hyperpigmentation with a Nd:YAG laser and a high speed rotary instrument. Methods: Three patients with melanin hyperpigmentation in the anterior parts of the gingiva were chosen for this case study. Clinical photographs were taken at the preoperative state and three patients were treated under local anesthesia. In the maxilla, the gingival deepithelization was conducted with a high speed diamond bur, whereas, in the mandible with a Nd:YAG laser. Clinical photographs were taken immediately after the procedures and at the 1st, 2nd, and 4th week to evaluate clinical color changes. A week after the procedure, the patients filled out a questionnaire about any pain or discomfort. At the 4th week after the procedure, the patients filled out questionnaires about esthetic aspects of the results of treatment. Results: In all cases, both anterior gingival areas were depigmented with satisfaction and the patients did not complain of severe pain or discomfort. At the 1st week of healing, the gingiva showed moderate to fast epithelization. Two weeks after the procedure, clinically, the gingiva showed almost complete healing. Four weeks after the procedure, there was significant improvement in gingival melanin hyperpigmentation. Conclusions: The Nd:YAG laser and the high speed rotary instruments seem to be effective for the esthetic treatment of gingival melanin hyperpigmentation.

Shear bond strength of resin cement to an acid etched and a laser irradiated ceramic surface

  • Kursoglu, Pinar;Karagoz Motro, Pelin Fatma;Yurdaguven, Haktan
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.98-103
    • /
    • 2013
  • PURPOSE. To evaluate the effects of hydrofluoric acid etching and Er,Cr:YSGG laser irradiation on the shear bond strength of resin cement to lithium disilicate ceramic. MATERIALS AND METHODS. Fifty-five ceramic blocks ($5mm{\times}5mm{\times}2mm$) were fabricated and embedded in acrylic resin. Their surfaces were finished with 1000-grit silicon carbide paper. The blocks were assigned to five groups: 1) 9.5% hydrofluoric-acid etching for 60 s; 2-4), 1.5-, 2.5-, and 6-W Er,Cr:YSGG laser applications for 60 seconds, respectively; and 5) no treatment (control). One specimen from each group was examined using scanning electron microscopy. Ceramic primer (Rely X ceramic primer) and adhesive (Adper Single Bond) were applied to the ceramic surfaces, followed by resin cement to bond the composite cylinders, and light curing. Bonded specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strengths were determined by a universal testing machine at 1 mm/min crosshead speed. Data were analyzed using Kruskal-Wallis and Mann-Whitney U-tests (${\alpha}$=0.05). RESULTS. Adhesion was significantly stronger in Group 2 ($3.88{\pm}1.94$ MPa) and Group 3 ($3.65{\pm}1.87$ MPa) than in Control group ($1.95{\pm}1.06$ MPa), in which bonding values were lowest (P<.01). No significant difference was observed between Group 4 ($3.59{\pm}1.19$ MPa) and Control group. Shear bond strength was highest in Group 1 ($8.42{\pm}1.86$ MPa; P<.01). CONCLUSION. Er,Cr:YSGG laser irradiation at 1.5 and 2.5 W increased shear bond strengths between ceramic and resin cement compared with untreated ceramic surfaces. Irradiation at 6 W may not be an efficient ceramic surface treatment technique.

$CO_2$ 레이저와 일반 수술도를 이용한 백서의 부분적설 절제술 후의 창상치유에 관한 비교연구 (COMPARATIVE STUDY OF WOUND HEALING FOLLOWING PARTIAL GLOSSECTOMY OF RAT TONGUE USING CO2 LASER AND SCALPEL)

  • 장재필;김경욱;이재훈;김창진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권5호
    • /
    • pp.437-445
    • /
    • 2000
  • Object This study is focused on the comparison between $CO_2$ laser and scalpel by examining the overal process of wound healing after partial glossectomy of rats so that the result from the research could be easily applied to actual clinical environment. Method and Material In this research, 2mm defect was formed on both lateral borders of the tongue of rats by using $CO_2$ laser and scalpel respectively. 4rats were sacrified each time on the 1st, 2nd, 4th, 7th, 14th and 21th day according to a general method. After fabricating $5{\mu}m$ paraffin specimen, H&E staining and MT staining were performed. Results Compared to scalpel, wound healing by $CO_2$ laser leads to a earlier initiation of vascular proliferation and re-epithelization. Therefore, some influence is exerted on the early stage of wound healing. However, the two methods seem to undergo the similar healing process.

  • PDF

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

Effects of Low Incident Energy Levels of Infrared Laser Irradiation on the Proliferation of Candida Albicans Part I : A Long Term Study according to Pulse Type

  • Sam-Kun Kim;Phil-Yeon Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제19권1호
    • /
    • pp.9-15
    • /
    • 1994
  • This experiment was performed to confirm the hypothesis that LLLT had biostimulation effect for all kinds of cells and there would be differences in the growth of cells among different types of pulsed laser. 360 samples were used in this study. The samples were randomly divided in 6 groups according to the pulse type : quasi continuous type (CW), pulse 1(P1), pulse 7(P7), pulse 9(P9), pulse 15(P15) and shame-irradiated control(Co) groups. Energy fluences of all experimental groups, P1, P7, P9, P15 and CW were 2.12, 2.12, 6.37, 57.32 and 31.85 mj/cm2 respectively. All samples were irradiated for every 1 minute at 0, 12, 24, 36, 48 and 60 hours. Ten samples of each group were sacrificed at 0 and every 12 hours and then the optical density of all samples was measured with the spectrophotometer. As a result, some types of pulses showed significant differences among groups. The increase of cells were markedly stimulated with laser irradiation in P7 and P9 groups, while inhibited in CW, P1, and P15 groups compared with control group. It is therefore, suggested that specific laser pulse should be recommanded to have the biostimulation effects on the specific tissue or cells, although the biostimulation effect is does dependant.

  • PDF

레이저 처리후 임프란트 표면 변화에 관한 연구 (The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive)

  • 김태정;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.