• Title/Summary/Keyword: laser alignment

Search Result 165, Processing Time 0.023 seconds

Evaluation of the Positional Accuracy of the Delivered Beams from the Target: A Phantom Study (방사선 치료에서 치료 표적과 조사 빔의 일치 정도 평가: 팬텀 연구)

  • Kang, Sei-Kwon;Cho, Byung-Chul;Cheong, Kwang-Ho;Ju, Ra-Hyeong;Kim, Su-Ssan;Kim, Kyoung-Ju;Choi, Sang-Gyu;Bae, Hoon-Sik;Lee, Re-Na;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.192-200
    • /
    • 2006
  • We evaluated the positional accuracy of the delivered beams to the target in a phantom by simulating the whole process of the radiation treatments Including CT scanning, planning and beam exposures with MLCs. For this purpose, a phantom was made to calibrate the alignment between the CT and the attached laser system. A new, convenient method was also devised to align the setup lasers in the treatment room. Film was used for the Identification of the delivered beam and analyzed with a homemade computer program. The positional differences between the target and the beam centers varied with the couch rotations. The accelerator we used showed a maximum discrepancy of 2.0 mm at the table angle of $295^{\circ}$. The same measurements based on the new isocenter from the Winston-Lutz test resulted in the maximum of 1.35 mm for all rotation angles. The evaluation of the differences between the target and the beam centers is useful for the treatment planning.

  • PDF

Graphene Quantum Dot Interfacial Layer for Organic/Inorganic Hybrid Photovoltaics Prepared by a Facile Solution Process (용액 공정을 통한 그래핀 양자점 삽입형 유/무기 하이브리드 태양전지 제작)

  • Kim, Youngjun;Park, Byoungnam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.646-651
    • /
    • 2018
  • This paper reports that the electronic properties at a $P3HT/TiO_2$ interface associated with exciton dissociation and transport can be tailored by the insertion of a graphene quantum dot (GQD) layer. For donor/acceptor interface modification in an $ITO/TiO_2/P3HT/Al$ photovoltaic (PV) device, a continuous GQD film was prepared by a sonication treatment in solution that simplifies the conventional processes, including laser fragmentation and hydrothermal treatment, which limits a variety of component layers and involves low cost processing. The high conductivity and favorable energy alignment for exciton dissociation of the GQD layer increased the fill factor and short circuit current. The origin of the improved parameters is discussed in terms of the broad light absorption and enhanced interfacial carrier transport.

Three-Dimensional Approaches in Histopathological Tissue Clearing System (조직투명화 기술을 통한 3차원적 접근)

  • Lee, Tae Bok;Lee, Jaewang;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.1-17
    • /
    • 2020
  • Three-dimensional microscopic approaches in histopathology display multiplex properties that present puzzling questions for specimens as related to their comprehensive volumetric information. This information includes spatial distribution of molecules, three-dimensional co-localization, structural formation and whole data set that cannot be determined by two-dimensional section slides due to the inevitable loss of spatial information. Advancement of optical instruments such as two-photon microscopy and high performance objectives with motorized correction collars have narrowed the gap between optical theories and the actual reality of deep tissue imaging. However, the benefits gained by a prolonged working distance, two-photon laser and optimized beam alignment are inevitably diminished because of the light scattering phenomenon that is deeply related to the refractive index mismatch between each cellular component and the surrounding medium. From the first approaches with simple crude refractive index matching techniques to the recent cutting-edge integrated tissue clearing methods, an achievement of transparency without morphological denaturation and eradication of natural and fixation-induced nonspecific autofluorescence out of real signal are key factors to determine the perfection of tissue clearing and the immunofluorescent staining for high contrast images. When performing integrated laboratory workflow of tissue for processing frozen and formalin-fixed tissues, clear lipid-exchanged acrylamide-hybridized rigid imaging/immunostaining/in situ hybridization-compatible tissue hydrogel (CLARITY), an equipment-based tissue clearing method, is compatible with routine procedures in a histopathology laboratory.

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

플라즈마 공정 진단을 위한 공간 분해 발광 분광 분석법 소개

  • Park, Chang-Hui;Kim, Dong-Hui;Choe, Seong-Won;Lee, Chang-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.81-81
    • /
    • 2013
  • 반도체, LCD, MEMs 등 미세 전자소자의 제작과 깊은 관련이 있는 IT 산업은 자동차 산업과 함께 세계 경제를 이끌고 있는 핵심 산업이며, 그 발전 가능성이 크다고 할 수 있다. 이 중 반도체, LCD 공정 기술에 관해서 대한민국은 세계를 선도하여 시장을 이끌어 나가고 있는 실정이다. 이들의 공정기술은 주로 높은 수율(yield)을 기반으로 한 대량 생산 기술에 초점이 맞추어져 있기 때문에, 현재와 같은 첨예한 가격 경쟁력이 요구되는 시대에서 공정 기술 개발을 통해 수율을 최대한으로 이끌어 내는 것이 현재 반도체를 비롯한 미세소자 산업이 직면하고 있는 하나의 중대한 과제라 할 수 있다. 특히 반도체공정에 있어 발전을 거듭하여 현재 20 nm 수준의 선폭을 갖는 소자들의 양산이 계획 있는데 이와 같은 나노미터급 선폭을 갖는 소자 양산과 관련된 CD (critical dimension)의 감소는 공차의 감소를 유발시키고 있으며, 패널의 양산에 있어서 생산 효율 증가를 위한 기판 크기의 대형화가 이루어지고 있다. 또한, 소자의 집적도를 높이기 위하여 높은 종횡비(aspect ratio)를 요구하는 공정이 일반화됨에 따라 단일 웨이퍼 내에서의 공정의 균일도(With in wafer uniformity, WIWU) 및 공정이 진행되는 시간에 따른 균일도(Wafer to wafer uniformity)의 변화 양상에 대한 파악을 통한 공정 진단에 대한 요구가 급증하고 있는 현실이다. 반도체 및 LCD 공정에 있어서 공정 균일도의 감시 및 향상을 위하여 박막, 증착, 식각의 주요 공정에 널리 사용되고 있는 플라즈마의 균일도(uniformity)를 파악하고 실시간으로 감시하는 것이 반드시 필요하며, 플라즈마의 균일도를 파악한다는 것은 플라즈마의 기판 상의 공간적 분포(radial direction)를 확인하여 보는 것을 의미한다. 현재까지 플라즈마의 공간적 분포를 진단하는 대표적인 방법으로는 랭뮤어 탐침(Langmuir Probe), 레이저 유도 형광법(Laser Induced Fluorescence, LIF) 그리고 광섬유를 이용한 발광분광법(Optical Emission Spectroscopy, OES)등이 있으나 랭뮤어 탐침은 플라즈마 본연의 상태에서 섭동(pertubation) 현상에 의한 교란, 이온에너지 측정의 한계로 인하여 공정의 실시간 감시에 적합하지 않으며, 레이저 유도 형광법은 측정 물질의 제한성 때문에 플라즈마 내부에 존재하는 다양한 종의 거동을 살필 수 없다는 단점 및 장치의 설치와 정렬(alignment)이 상대적으로 어려워 산업 현장에서 사용하기에 한계가 있다. 본 연구에서는 최소 50 cm에서 최대 400 cm까지 플라즈마 내 측정 거리에서 최대 20 mm 공간 분해가 가능한 광 수광 시스템 및 플라즈마 공정에서의 라디칼의 상태 변화를 분광학적 비접촉 방법으로 계측할 수 있는 발광 분광 분석기를 접목하여 플라즈마 챔버 내의 라디칼 공간 분포를 계측할 수 있는 진단 센서를 고안하고 이를 실 공정에 적용하여 보았다. 플라즈마 증착 및 식각 공정에서 형성된 박막의 두께 및 식각률과 공간 분해발광 분석법을 통하여 계측된 결과와의 매우 높은 상관관계를 확인하였다.

  • PDF