• Title/Summary/Keyword: large scale testing

Search Result 230, Processing Time 0.023 seconds

A framework for distributed analytical and hybrid simulations

  • Kwon, Oh-Sung;Elnashai, Amr S.;Spencer, Billie F.
    • Structural Engineering and Mechanics
    • /
    • v.30 no.3
    • /
    • pp.331-350
    • /
    • 2008
  • A framework for multi-platform analytical and multi-component hybrid (testing-analysis) simulations is described in this paper and illustrated with several application examples. The framework allows the integration of various analytical platforms and geographically distributed experimental facilities into a comprehensive pseudo-dynamic hybrid simulation. The object-oriented architecture of the framework enables easy inclusion of new analysis platforms or experimental models, and the addition of a multitude of auxiliary components, such as data acquisition and camera control. Four application examples are given, namely; (i) multi-platform analysis of a bridge with soil and structural models, (ii) multiplatform, multi-resolution analysis of a high-rise building, (iii) three-site small scale frame hybrid simulation, and (iv) three-site large scale bridge hybrid simulation. These simulations serve as illustrative examples of collaborative research among geographically distributed researchers employing different analysis platforms and testing equipment. The versatility of the framework, ease of including additional modules and the wide application potential demonstrated in the paper provide a rich research environment for structural and geotechnical engineering.

Development of 250kW Power Conditioning System for Large Scale Photovoltaic Power Plant (대규모 태양광 발전설비를 위한 전력변환기 개발)

  • Kang, Ho-Hyun;Jung, Hong-Ju;Kim, Wang-Mun;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.640-642
    • /
    • 2008
  • This paper presents the design, development and performance of a 250kW power conditioning system(PCS) for large scale photovoltaic power plant. The PV inverter consists of a three phase IGBT stack, L-C filter, transformer and HMI unit for monitoring. To verify the performance of the PV inverter a testing facility was designed and constructed to simulate the characteristics of the solar cell and grid.

  • PDF

A Large Scale Smart-Grid field-test in Jeju (제주 Smart-Grid 대규모 실증단지 구축 현황)

  • NamKoong, Won;Ha, Bok-Nam;Lee, Sung-Woo;Seo, In-Yong;Jang, Moon-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Five smart grid projects was started with large scale at Jeju Island in South Korea from 2009, and smart-grid test-bed was started in Nov. 2010. The five projects are Smart Power Grid (SPG), Smart Renewable (SR), Smart Transportation (ST), Smart Place (SP) and Smart Electric Service (SES). Korea government constructed the smart grid public relations center at Nov. 2010 in Jeju Island and there will be continued the field operation and interface testing among five smart gird projects until May. 2013.

MODIFIED POSTERIOR TIME-STEP ADJUSTMENT TECHNIQUE FOR MDOF SYSTEM IN SUBSTRUCTURING PSEUDODYNAMIC TEST (부분구조 유사동적법에 있어 다자유도 시스템에 대한 수정 시간증분 조정기법)

  • 이원호;강정호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.473-480
    • /
    • 1998
  • The substructuring pseudodynamic test is a hybrid testing method consisting of a numerical simulation of the earthquake response of an analytical model and a loading test of a specimen. The substructuring pseudodynamic testing technique has been applied to various seismic experiments since it has advantages over the shaking table test to study dynamic behaviors of relatively large scale structures. However, experimental errors are inevitable in substructuring pseudodynamic testing. Some of these errors can be monitored during the test, but, due to limitations in control system, they cannot be eliminated. For example, one cannot control exactly the displacements that are actually imposed on the structures at each time step. This paper focuses on a technique to minimize the cumulative effect of such control errors for MDOF system. For this purpose, the modified posterior adjustment of the time increment from a target value $\Delta$t$_{n}$ to an adjusted value is performed to minimize the effect of the control errors for MDOF system.for MDOF system.

  • PDF

Comparative Performance Analysis of Robot-based Automated Construction System Using a Real Scale Test Project

  • Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.3
    • /
    • pp.339-349
    • /
    • 2015
  • A large-scale research project to develop a robot-based automated building construction system for steel structures was successfully conducted in South Korea. This paper discusses the results of the real-scale test and the key lessons gained from the testing process. The system was assessed in terms of system productivity, construction cost, quality control, and safety improvements. While the productivity of the automated system showed an improvement of about 9.5%, the construction cost was about six times higher than that of the conventional method. The field test also indicated that the automated system requires more on-site quality control measures. However, because the system can eliminate the causes of various safety accidents, safety levels might be expected to be improved significantly. It is expected that this paper will provide knowledge and insight for developing new systems, and the results of the real-scale test might be useful for other researchers and similar research projects in the future.

A Dynamic Management Technique for Weighted Testcases in Software Testing (가중치를 이용한 소프트웨어 테스트케이스 동적 관리 기법)

  • Han, Sang-Hyuck;Jung, Jung-Su;Jin, Seung-Il;Kim, Young-Kuk
    • The KIPS Transactions:PartD
    • /
    • v.17D no.6
    • /
    • pp.423-430
    • /
    • 2010
  • As software becomes large-scale and complicated, the need for Quality Assurance and management is increased and software testing is becoming more important. The main aims of software testing are not only detecting and handling the defects in the system but also investigating and managing the present system. But automatic testing tools require lots of time and efforts to detect and manage the risk in the system because test-cases used in the general automatic testing tools have the simply static information. In this thesis, the dynamic management technique for weighted testcases is designed to test the high-risk testcases preferentially by giving the testcases dynamic weight.

Development of Magnetic Sensor for Measurement of the Cable Tension of Large Scale Bridge (대형교량 케이블 장력 측정을 위한 자기센서 개발)

  • Park, Hae-Won;Ahn, Bong-Young;Lee, Seung-Seok;Kim, Jong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.339-344
    • /
    • 2007
  • Safety of large scale cable in bridge is very important because it may cause the unwanted catastrophic failure. Although the proof load were considered at the design stage, its soundness must be monitored continuously because the cable may be broken out without warning by the variable external load. The cable tension of in-use structures has been mainly measured by the resonance method and its use has been limited because of relatively large measurement uncertainty. Recently a new magnetic method was developed and its reliability is known to be good for evaluating the cable tension. In this study a system which can deliver the calibrated load to the cable was developed and the measurement reliability of developed magnetic sensor according to the change of external load was analyzed quantitatively. The effect of magnetization frequency, bias magnetic field, and temperature on the sensor output was also evaluated.

Finite Element Based Multi-Scale Ductile Failure Simulation of Full-Scale Pipes with a Circumferential Crack in a Low Carbon Steel (유한요소기반 다중스케일 연성파손모사 기법을 이용한 원주방향 균열이 존재하는 탄소강 실배관의 파손예측 및 검증)

  • Han, Jae-Jun;Bae, Kyung-Dong;Kim, Yun-Jae;Kim, Jong-Hyun;Kim, Nak-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.727-734
    • /
    • 2014
  • This paper describes multi-scale based ductile fracture simulation using finite element (FE) damage analysis. The maximum and crack initiation loads of cracked components were predicted using proposed virtual testing method. To apply the local approach criteria for ductile fracture, stress-modified fracture strain model was adopted as the damage criteria with modified calibration technique that only requires tensile and fracture toughness test data. Element-size-dependent critical damage model is also introduced to apply the proposed ductile fracture simulation to large-scale components. The results of the simulation were compared with those of the tests on SA333 Gr. 6 full-scale pipes at $288^{\circ}C$, performed by the Battelle Memorial Institute.

A Study on Testing of 1/4-scale and Full-size Seismic Isolation Bearings (축소모델과 실모델 면진베어링의 성능실험에 관한 연구)

  • 정민기;정지만;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.194-202
    • /
    • 1996
  • An approach to increase the seismic resistance of large structures is to reduce the seismic forces, to which structures are subjected by base isolation systems. The anti-seismic performance of base-isolated beatings has been verified experimentally by shaking table tests. However, it may be difficult to perform the tests for the full-scale beatings of base-isolated structures. Therefore, the test program was designed to evaluate the reliability and properties of the beatings under a range of loading conditions including axial stress, loading frequency and direction, and temperature. The effects of scale were also evaluated by comparing the results of the 1/4-scale beatings with those from the full-scale bearings, and the ultimate behavior of both types of bearings with evaluated through a series of roll-out tests. This report draws comparisons among the different tests and bearings to determine the importance of various factors including load history, axial stress, and frequency. Comparisons between the 1/4-scale bearings were difficult because of the scaling effects in manufacturing and thermal radiation, but qualitative results from the 1/4-scale bearings can certainly be extrapolated the full-scale bearings.

  • PDF

Identification of flutter derivatives from full-scale ambient vibration measurements of the Clifton Suspension Bridge

  • Nikitas, Nikolaos;Macdonald, John H.G.;Jakobsen, Jasna B.
    • Wind and Structures
    • /
    • v.14 no.3
    • /
    • pp.221-238
    • /
    • 2011
  • The estimated response of large-scale engineering structures to severe wind loads is prone to modelling uncertainties that can only ultimately be assessed by full-scale testing. To this end ambient vibration data from full-scale monitoring of the historic Clifton Suspension Bridge has been analysed using a combination of a frequency domain system identification method and a more elaborate stochastic identification technique. There is evidence of incipient coupling action between the first vertical and torsional modes in strong winds, providing unique full-scale data and making this an interesting case study. Flutter derivative estimation, which has rarely previously been attempted on full-scale data, was performed to provide deeper insight into the bridge aerodynamic behaviour, identifying trends towards flutter at higher wind speeds. It is shown that, as for other early suspension bridges with bluff cross-sections, single-degree-of-freedom flutter could potentially occur at wind speeds somewhat below requirements for modern designs. The analysis also demonstrates the viability of system identification techniques for extracting valuable results from full-scale data.