• Title/Summary/Keyword: large scale model test

Search Result 422, Processing Time 0.036 seconds

Shear Load characteristics of drilled shafts considering socket-roughness in Constant Normal Stiffness(CNS) Test (일정수직강성시험을 통한 암반근입 현장타설말뚝의 주면마찰력특성분석)

  • Jeong, Sang-Seom;Jung, Woo-Hyun;Seol, Hoon-Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.489-498
    • /
    • 2005
  • In this study, the shaft resistance of drilled shafts socketed into weathered-and soft-rocks was examined by the constant normal stiffness(CNS) test. Large scale model tests were performed for different unconfined compressive strength, socket roughness, initial normal stress, and normal stiffness for identifying shear load transfer characteristics. Through comparisons with previous studies, it is found that the results by the present approach is good agreement with the general trend observed by existing empirical and analytical results.

  • PDF

Static Behavior of Reinforced Railway Roadbed by Geotextile Bag (지오텍스타일 백으로 보강된 철도노반의 정적거동 분석)

  • Lee, Dong-Hyun;Shin, Eun-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.2 s.33
    • /
    • pp.180-186
    • /
    • 2006
  • In this study, a large-scale laboratory model test, 2-D and 3-D numerical analyses were conducted to verify the reinforcement effect by utilizing geotextile bag on the railway roadbed. Static loading which simulated train load was applied on the geotextile bag-reinforced railway roadbed and also unreinforced railway roadbed, Computer program named Pentagon which is a part of FEM programs was used in the numerical analysis. Based on the results of laboratory test, 2-D and 3-D numerical analyses, the effect of load distribution and settlement reduction was found to be depending on the geotextile characteristics, tensile strength of geotextite, and interface friction angle between geotextile bags. In general, the result of 2-D and 3-D numerical analyses shows lower value than that of laboratory test. Also, the result of 3-D numerical analyses shows lower value than that of 2-D numerical analyses because of its stress transfer effect.

Experimental study on seepage characteristics of large size rock specimens under three-dimensional stress

  • Sun, Wenbin;Xue, Yanchao;Yin, Liming;Zhang, Junming
    • Geomechanics and Engineering
    • /
    • v.18 no.6
    • /
    • pp.567-574
    • /
    • 2019
  • In order to study the effect of stress and water pressure on the permeability of fractured rock mass under three-dimensional stress conditions, a single fracture triaxial stress-seepage coupling model was established; By using the stress-seepage coupling true triaxial test system, large-scale rock specimens were taken as the research object to carry out the coupling test of stress and seepage, the fitting formula of permeability coefficient was obtained. The influence of three-dimensional stress and water pressure on the permeability coefficient of fractured rock mass was discussed. The results show that the three-dimensional stress and water pressure have a significant effect on the fracture permeability coefficient, showing a negative exponential relationship. Under certain water pressure conditions, the permeability coefficient decreases with the increase of the three-dimensional stress, and the normal principal stress plays a dominant role in the permeability. Under certain stress conditions, the permeability coefficient increases when the water pressure increases. Further analysis shows that when the gob floor rock mass is changed from high stress to unloading state, the seepage characteristics of the cracked channels will be evidently strengthened.

Engineering-scale Validation Test for the T-H-M Behaviors of a HLW Disposal System (고준위폐기물 처분시스템의 열적-수리적-역학적 거동 규명을 위한 공학적 규모의 실증시험)

  • Lee Jae-Owan;Park Jeong-Hwa;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.197-207
    • /
    • 2006
  • The engineering performance of a high level waste repository is significantly dependent upon the T-H-M behavior in the engineered barrier system. An engineering-scale test facility (KENTEX) was set up to validate the T-H-M behaviors in the buffer of a reference disposal system developed in the 2002. The validation tests started on May 31, 2005 and is now in progress. The KENTEX facility and validation test programme are introduced, and pre-operation calculations are also presented to give information on the sensitive location of sensors and operational conditions. This test will provide information (e.g., large-scale apparatus, sensors, monitoring system etc.) needed for 'in-situ' tests, make the validation of a T-H-M model for the T-H-M performance assessment of the reference disposal system, and demonstrate the engineering feasibility of fabricating and emplacing the buffer of a repository.

  • PDF

Behavior of Tunnel Due to Adjacent Ground Excavation with Pre-loading on Braced Wall (근접 굴착시 흙막이벽 버팀대 선행하중 재하에 따른 터널의 거동)

  • Kim, Il;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.163-174
    • /
    • 2007
  • A New pre-loading system, through which a large pre-load could be charged was developed and applied to the braced wall in order to stabilize the adjacent tunnel. A pre-load larger than the designated axial force of bracing was imposed to prevent the horizontal displacement of the braced wall during the ground excavation. For this purpose, real scale model tests (1/10) were conducted, without and with pre-load on braced wall. And numerical analyses were performed for both the cases without and with pre-load, which were half (50%) and full (100%) respectively, and larger scale of the design axial farce of bracing. FEM program called PLAXIS was used for numerical analysis. As a result, it was found that the stability of the existing tunnel adjacent to the braced wall could be greatly enhanced when the horizontal displacement of braced wall was reduced by applying a pre-load, which was larger than the designated axial force of bracing.

Shake-table responses of a low-rise RC building model having irregularities at first story

  • Lee, Han Seon;Jung, Dong Wook;Lee, Kyung Bo;Kim, Hee Cheul;Lee, Kihak
    • Structural Engineering and Mechanics
    • /
    • v.40 no.4
    • /
    • pp.517-539
    • /
    • 2011
  • This paper presents the seismic responses of a 1:5-scale five-story reinforced concrete building model, which represents a residential apartment building that has a high irregularity of weak story, soft story, and torsion simultaneously at the ground story. The model was subjected to a series of uni- and bi-directional earthquake simulation tests. Analysis of the test results leads to the following conclusions: (1) The model survived the table excitations simulating the design earthquake with the PGA of 0.187 g without any significant damages, though it was not designed against earthquakes; (2) The fundamental mode was the torsion mode. The second and third orthogonal translational modes acted independently while the torsion mode showed a strong correlation with the predominant translational mode; (3) After a significant excursion into inelastic behavior, this correlation disappeared and the maximum torsion and torsion deformation remained almost constant regardless of the intensity of the two orthogonal excitations; And, (4) the lateral resistance and stiffness of the critical columns and wall increased or decreased significantly with the large variation of acting axial forces caused by the high bi-directional overturning moments and rocking phenomena under the bi-directional excitations.

A Study on Development of Scaled-down HVDC Model (HVDC의 축소형 모델 개발에 관한 연구)

  • Ahn, Jong-Bo;Yun, Jae-Young;Kim, Kook-Hun;Lee, Jong-Moo;Kim, Jong-Moon;Lee, Ki-Do
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.219-221
    • /
    • 1999
  • HVDC(High Voltage Direct Current) transmission system was constructed between Cheju island and mainland Haenam and has been operating commercially since 1998. But research activities in this area are not so much. That is caused by the facts that HVDC is large scale system and it is not so easy to implement and to test. Though such simulation tools as RTDS(Real Time Digital Simulator) and EMTDC can be useful, these have limitations for actual control and protective system design. Therefore scaled-down HVDC model was developed for the purpose of researches at operating technique, control and protection methods. The design of this model was based on real Cheju-Haenam HVDC system. And additionally faults simulator such as ground fault, short-circuit and change of impedance in transmission line is equipped for analysis of these faults. Control system of the model was implemented fully digitally. So it is very easy for the researchers to develope control and protection algorithm and to test the performance.

  • PDF

A proposed technique for determining aerodynamic pressures on residential homes

  • Fu, Tuan-Chun;Aly, Aly Mousaad;Chowdhury, Arindam Gan;Bitsuamlak, Girma;Yeo, DongHun;Simiu, Emil
    • Wind and Structures
    • /
    • v.15 no.1
    • /
    • pp.27-41
    • /
    • 2012
  • Wind loads on low-rise buildings in general and residential homes in particular can differ significantly depending upon the laboratory in which they were measured. The differences are due in large part to inadequate simulations of the low-frequency content of atmospheric velocity fluctuations in the laboratory and to the small scale of the models used for the measurements. The imperfect spatial coherence of the low frequency velocity fluctuations results in reductions of the overall wind effects with respect to the case of perfectly coherent flows. For large buildings those reductions are significant. However, for buildings with sufficiently small dimensions (e.g., residential homes) the reductions are relatively small. A technique is proposed for simulating the effect of low-frequency flow fluctuations on such buildings more effectively from the point of view of testing accuracy and repeatability than is currently the case. Experimental results are presented that validate the proposed technique. The technique eliminates a major cause of discrepancies among measurements conducted in different laboratories. In addition, the technique allows the use of considerably larger model scales than are possible in conventional testing. This makes it possible to model architectural details, and improves Reynolds number similarity. The technique is applicable to wind tunnels and large scale open jet facilities, and can help to standardize flow simulations for testing residential homes as well as significantly improving testing accuracy and repeatability. The work reported in this paper is a first step in developing the proposed technique. Additional tests are planned to further refine the technique and test the range of its applicability.

On the Ultimate Longitudinal Strength Assessment of Ships' Hull Structure (선체 선각구조의 최종 종강도 평가에 관한 연구)

  • Lee, Hun-Gon;Lee, Joo-Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.3 s.147
    • /
    • pp.340-350
    • /
    • 2006
  • This paper is concerned with a practical guide for the ultimate longitudinal strength assessments of ships' hull structure. Rigorous non-linear structural analysis for three tanker models has been carried out to examine the ultimate strength behavior. Formula of estimating the ultimate longitudinal strength has been proposed which is modified with the results of non-linear finite element analysis of hull girders. Computational reliability and accuracy of the large-scale non-linear finite element analysis and the proposed simplified formula are verified through comparing their results with that of 1/3 scale frigate model test and DNVs program. Additionally, the ultimate longitudinal strength for ten tanker models is compared with those by the method specified in the 2nd Draft of common structural rule for tankers, which is being developed by IACS.

Shaking Table Tests of A 1/12-Scale Reinforced Concrete Upper-Wall Lower-Frame Structure (1/12 축소 철근콘크리트 주상복합구조물의 진동대실험)

  • 이한선;김상연;고동우;권기혁;김병현
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.139-144
    • /
    • 2001
  • The objective of this study is to investigate the behavior of 1/12 scale upper-wall lower-frame reinforced concrete structure subjected to earthquake excitations. For this purpose, Taft N21E earthquake accelerogram was simulated by using 4m$\times$4m shaking table. When the input acceleration is compared to that of output, it was found that simulation of shaking table is satisfactory. From the test results with peak ground acceleration(PGA) 0.22g, which corresponds to 0.11g in prototype by the similitude law, it can be observed that the model responded in elastic behavior and that large interstory drift occurred at the lower part of the structure.

  • PDF