• 제목/요약/키워드: large scale fire test

검색결과 51건 처리시간 0.024초

실대화재시험의 화재성능 등급분류에 관한 연구 (Study on the combustion performance's classification system for large scale fire tests)

  • 박계원;임홍순;정재군
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.99-104
    • /
    • 2008
  • The combustion properties of sandwich panels were tested and analyzed according to ISO 13784-1(Room Corner Test for Sandwich panel building systems) test method for the purpose of establishing the classification of reaction to fire performance. Several variables including heat release rate, smoke production rate, FIGRA, SMOGRA, and so on, were analyzed for specific four materials about sandwich panel systems on each 5 times, totally 20 times. Finally, elements for Classification system were suggested and evaluations for those elements were made.

  • PDF

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • 제12권4호
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

Cracks evolution and multifractal of acoustic emission energy during coal loading

  • Kong, Xiangguo;Wang, Enyuan;He, Xueqiu;Liu, Xiaofei;Li, Dexing;Liu, Quanlin
    • Geomechanics and Engineering
    • /
    • 제14권2호
    • /
    • pp.107-113
    • /
    • 2018
  • Coal samples with different joints morphology were subjected to uniaxial compression experiments, cracks evolution was recorded by Nikon D5300 and acoustic emission (AE) energy signals were collected by AEwin Test for Express-8.0. During loading process, coal samples deformed elastically with no obvious cracks changes, then they expanded gradually along the trace of the original cracks, accompanied by the formation of secondary cracks, and eventually produced a large-scale fracture. It was more interesting that the failure mode of samples were all shear shape, whatever the original cracks morphology was. With cracks and damage evolution, AE energy radiated regularly. At the early loading stage, micro damage and small scale fracture events only induced a few AE events with less energy, while large scale fracture leaded to a number of AE events with more energy at the later stage. Based on the multifractal theory, the multifractal spectrum could explain AE energy signals frequency responses and the causes of AE events with load. Multifractal spectrum width (${\Delta}{\alpha}$), could reflect the differences between the large and small AE energy signals. And another parameter (${\Delta}f$) could reflect the relationship between the frequency of the least and greatest signals in the AE energy time series. This research is helpful for us to understand cracks evolution and AE energy signals causes.

사무용 공간의 화재 성장 예측을 위한 실물화재실험 (The Study on Real Scale Fire Test for Fire Growth of Office)

  • 권오상;김흥열;김정현
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.278-281
    • /
    • 2012
  • 사무공간의 화재성상을 예측하기 위해 화재하중 $25kg/m^2$ 값을 적용하여 $2.4(L){\times}3.6(W){\times}2.4(H)\;m$ 크기의 Mock-up 화재실험을 진행하였다. 화재실험은 실물화재실험 장비인 LSC(Large Scale Calorimeter)에서 실시하였으며, 열방출률 및 질량감소율을 측정하였다. 실물화재실험 시작 후 약 1110 초에 플래시오버가 발생하였으며, 최대 열발출률은 1241.1 KW로 측정되었고 질량은 초기 219 kg에서 102 kg로 감소하였다.

  • PDF

Ro-Ro 구역용 미분무 소화설비의 개발을 위한 실험적 연구 (An experimental study on development of water mist fire-fighting systems for Ro-Ro spaces)

  • 곽지현;김영한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권8호
    • /
    • pp.946-952
    • /
    • 2013
  • 선박의 Ro-Ro 구역이나 특별범주구역의 화재방호를 위해 설치하는 고정식 수계소화설비의 개발 및 실용화를 위해, 특히 방수량이 적으며 관련기준에서 요구하는 성능요건을 만족하는 미분무 노즐을 개발하고자 실물화재실험을 수행하였다. 본 설비의 화재시나리오는 크게 두 가지로 트럭화물화재와 승용차화재로 구분되며, 각각 고정 설치된 미분무 노즐과 화원과의 세 가지 위치에 대한 시나리오로 이루어져 있다. 모든 화재실험은 30분간 진행되었으며 천장부의 가스온도와 우드펠릿의 손상율, 타깃합판의 착화여부로 판단되었다. 본 논문은 두 가지 화재실험 중 조건이 더욱 까다로운 트럭화재용 미분무 노즐의 결과를 위주로 방수압력과 방수량, 미분무수의 유동특성에 따른 화재실험결과와 화재진압특성을 고찰하였으며, 수십 회의 반복실험 결과 분당 약 40 L의 유량을 가지는 저압 미분무 노즐로 Ro-Ro구역의 화재진압이 가능한 것으로 나타났다.

Fire resistance of high strength concrete filled steel tubular columns under combined temperature and loading

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • 제27권2호
    • /
    • pp.243-253
    • /
    • 2018
  • In recent years, concrete-filled box or tubular columns have been commonly used in high-rise buildings. However, a number of fire test results show that there are significant differences between high strength concrete (HSC) and normal strength concrete (NSC) after being subjected to high temperatures. Therefore, this paper presents an investigation on the fire resistance of HSC filled steel tubular columns (CFTCs) under combined temperature and loading. Two groups of full-size specimens were fabricated to consider the effect of type of concrete infilling (plain and reinforced) and the load level on the fire resistance of CFTCs. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The results demonstrate that the higher the axial load level, the worse the fire resistance. Moreover, in the bar-reinforced concrete-filled steel tubular columns, the presence of rebars not only decreased the spread of cracks and the sudden loss of strength, but also contributed to the load-carrying capacity of the concrete core.

UML 2.0 모델 기반의 교전통제 소프트웨어 아키텍처 개발 (Development of the Engagement Control Software Architecture Based on UML 2.0 Model)

  • 유명환;배정일;신진화;조길석
    • 한국군사과학기술학회지
    • /
    • 제10권4호
    • /
    • pp.20-29
    • /
    • 2007
  • The engagement control software embedded in the weapon control computer of the fire control center for air defense missile system is large-scale real-time software. The use of typical software development methodologies is not appropriate to develop such large-scale embedded software in terms of reusability, reliability, and productivity for the reason that it is significantly complicated, and highly dependent on hardware platforms and developers. In this paper, a model-based software architecture using components based on UML 2.0 for the engagement control software is presented in order to solve these problems. This software architecture is verified using the black-box test, the scenario-based test, and the Ethernet packet monitoring test methods. The results demonstrate that the developed software architecture can be employed to enhance reusability, maintainability, and productivity of large-scale embedded software.

하이브리드 복합재 철도차량 차체의 화재 안전성 평가연구 (A Study on the Fire Safety of a Hybrid Composite Train Carbody)

  • 김정석;이덕희;정우성;조세현
    • Composites Research
    • /
    • 제21권4호
    • /
    • pp.1-6
    • /
    • 2008
  • 본 논문에서는 탄소/에폭시 면재와 알루미늄 허니콤 심재를 갖는 바디와 스테인레스 언더프레임을 갖는 철도차량 차체에 대한 화재안전성평가 시험을 수행하였다. 이를 위해 실규모 차체를 제작하고 이를 이용하여 시험을 수행하였다. 시험에 적용된 차체는 내장재가 포함되지 않은 차체와 내장재를 포함을 차체 두가지를 이용하였으며 시험조건은 대구지하철 화재사고 시나리오에 근거하여 설정하였다. 시험결과 차체 및 내장재 표면의 최대온도는 각각의 발화온도에 미치지 못함을 확인하였고, 차체 내부에 화염전파도 발생하지 않았다.

Performance of Adhesives in Glulam after Short Term Fire Exposure

  • Quiquero, Hailey;Chorlton, Bronwyn;Gales, John
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.299-311
    • /
    • 2018
  • As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.