• Title/Summary/Keyword: large error

Search Result 2,304, Processing Time 0.034 seconds

Crystallographic Study on the Selectivity and Distribution of Sr2+ Ions Within Zeolite A In the Presence of Competing Na+ Ions in Aqueous Exchange Solution (Na+ 경쟁이온이 존재하는 수용액에서 Zeolite A 내 Sr2+ 이온의 선택성 및 분포에 관한 결정학적 연구)

  • kim, Hu Sik;Park, Jong Sam;Lim, Woo Taik
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.1
    • /
    • pp.41-50
    • /
    • 2022
  • To study the properties of Sr2+ exchange into zeolite A with increasing the molar concentration of Na+ in given exchange solution, four single crystals of fully dehydrated Sr2+- and Na+- exchanged zeolite A were prepared by the bath method using mixed ion-exchange solutions. The Sr(NO3)2:NaNO3 molar rations of the ion exchange solution were 1:1(crystal 1), 1:100(crystal 2), 1:250(crystal 3), and 1:500 (crystal 4), respectively, with a total concentration of 0.05 M. The single-crystals were then vacuum dehydration at 623 K and 1×10-4 Pa for 2 days. Their single-crystal structures were determined by single-crystal synchrotron X-ray diffraction techniques in the cubic space group Pm3-m, at 100(1) K, and were then refined to the final error indices of R1/wR2=0.047/0.146, 0.048/0.142, 0.036/0.128, and 0.040/0.156 for crystals 1, 2, 3, and 4, respectively. In crystals 1 and 2, the 6 Sr2+ ions are found at three different crystallographic sites. In crystal 3, 1 Sr2+ and 10 Na+ ions are found in large cavity and sodalite unit. In crystal 4, only 12 Na+ ions occupy three equipoints. The degree of Sr2+ ion-exchange decreased sharply from 100 to 16.7 to 0% as the initial Na+ concentration increase and the Sr2+ concentration decrease. In addition, the unit cell constant of the zeolite framework decreased with this lower level of Sr2+ exchange.

The Study on the investigation of oriental medical theraphy(oriental medical theraphy by symptoms and signs and Sasang constitutional medicine)and the each effect of oriental medicine, occidental medicine and both joint control (뇌졸중(腦卒中)에 대(大)한 한방치료법(韓方治療法) 연구(硏究)(증치의학(證治醫學)과 사상의학(四象醫學)) 및 한방(韓方), 양방(洋方), 양(洋)·한방(韓方) 협진치료(協診治療) 효과(效果)에 관(關)한 연구(硏究))

  • Kim, Jong-won;Kim, Young-kyun;Kim, Beob-young;Lee, In-seon;Lee, In-seon;Jang, Kyung-jeon;Gwon, Jeong-Nam;Lee, Won-oe;Song, Chang-won;Park, Dong-il
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.2
    • /
    • pp.351-429
    • /
    • 1998
  • The Purpose of Study 1. Inspection of clinical application on TCD to CVA 2. Objective Comparement and analysis about treatment effect of Western-Medicine, Korean Medicine, Cooperative consultation of Korean and Western medicice for CVA The Subject of Study We intended for the eighty six patient of CVA who had been treated in the Oriental Medical Hospital at Dong Eui Medical Center from 1997. 8. I to 1998. 7. 31 1. View of CT, MRI : the patient of Cb infarction 2. Attack Time : The patient who coming hospital falling ill within the early one week The method of study 1. Treat four group of Korean medicine, Constitution medicine, Western medicine, cooperative consultation of Korean medicine and Western medicine. 2. Application of TCD Check the result for three times, immediatly after the attack, two months later, four months later 3. Comparative analysis of each treatment effect by clinical symptoms and pathologic examination 4. The Judgement of the patient The Result From 8/1/1997 to 7/31/1998, We have the following result by clinical analysis intended for CVA 86 patients who had been treated in the Oriental Medical Hospital at Dong Eui Medical Center from 1997. 8. 1 to 1998. 7. 31 in 1. Analysis according to Age The first stage of thirties, forties, seventies is heavier than forties, fifties in improvement and Index of improvement of symptom 2. Analysis according to sex We have no special relation in an average of symptom and improvement, Index improvement 3. Analysis according to Family History We have the better result in first stage and improvement, index improvement when no family history. 4. Analysis according to Past History We have no special relation in past history like hypertension, DM, heart problem 5. Analysis devided two group, above group and under group on the basis of the average in first stage of all patient. We have the better result when the first stage is light, that the first score of barthel index and CNS is high. 6. Analysis of the effect of treatment about Korean medical treatment, Western medical treatment, cooperative treatment. In this study, the highest group of rate of treatment at four contrast groups (Korean medicine, Constitution medicine, Western medicine, cooperative treatment according to dyagnosis and range of treatment was the patient group of doing dyagnosis and method of treatment based on constitution medicine theory. This is that of doing demostation, A-Tx, po-herb-medication according to dyagnosis and treat method of constitution of Lee Je-ma In case of left, the case of dyagnosis any disease according to doctor view but, normal in TCDwas 22-beginning of attack, 20- two weeks later, 11 case-four weeks later in case of right, 15-beginning of attack, 12-two weeks later, 9 case four weeks later. So left vessel compares to right vessel is more interference, in fact more than a 1/2 of the patients of MCA disease can't do dyagnosis. In rate of imparement, the state of pacient improved but there isn't the improved case of result in TCD. 7. In TCD dyagnosis, between the case of inconsus the doctor view specially MCA in brain blood vessel is in large numbers and in total 86's patient, impossible case of dyagnosis according to interferiance of temporal is 21 case. 7. Result study about application of Kreaan medical treatment 1) The impossible patient of observation MCA blood vescular for interference temporal bone happened in large numbers. 2) There is the case having difference result to CT,MRI, MRA result. 3) Because individual difference is large, excluding to ananalogy of symptom. This is normal numerical value that has possibility of being checked as abnormal numerical value 4) there are a lot of cases that the speed of normal part is as similarly measured as that of abnormal part. It means that we cannot judge the disease by this measure 5) It is rare that this measure represent degree of improvement in patient's condition of disease. When we observe patient's condition become better, but we have no case that the result of TCD test better. 6) The result could be appear differently by the technique of the tester or by the experience of the tester 7) In the TCD test, abnormal symptoms is checked at 0 week, but at 2th week, normal symptoms is checked, again at 4th week abnormal is checked. According to the above result, CVA diagnosis is difficult only with TCD, as it appear in diagnosis error check which is suggested in the problem connected to project, for the aged persons who have the worst hardening of part of the cranium (1998. 5. 26 77 of 83 patients is 50s) there is a lot of cases that the measurement is impossible by TCD and the correction of measurement numerical value is decreased, as the age of cerebral infarction is high, TCD is inappropriate to diagnosis equipment through this study.

  • PDF

Validity of Clinically Used Tray Transmission Factor (임상적으로 쓰이는 차폐선반투과율의 타당성에 관한 연구)

  • 윤형근
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.218-224
    • /
    • 2003
  • Purpose:By evaluating the dependence of the tray transmission factor (tray factor) on collimator setting and tray thickness, we determined the validity of the clinically used single tray factor for standard radiation field size (10${\times}$10 $\textrm{cm}^2$). Methods and Materials:For each X ray energies (6 and 10 MV), outputs were measured by using 5 steps of tray thickness (0, 6, 8, 10, 12 mm) and 7 steps of radiation field size (5${\times}$5, 10${\times}$10, 15${\times}$15, 20${\times}$20, 25${\times}$25, 30${\times}$30, 35${\times}$35 $\textrm{cm}^2$) at 10 cm phantom depth. Outputs were measured in both 'with tray' and 'without tray' conditions by using radiation with the same monitor units, and the tray factors were determined by the ratios of the two outputs. To evaluate the validity of a single tray factor obtained for standard radiation field, we analyzed the pattern of the field sizes in cases treated at our hospital in 2002. Results : In the 6 MV X-ray, the increases in the tray factor between the standard field (l0${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.835%, 1.058%, 1.066% in 6, 8, 10, and 12 mm thickness tray, respectively. In the 10 MV X-ray, the increases in the fray factor between the standard field (10${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.836%, 1.058%, 1.066% in 6, 8, 10, 12 mm thickness tray, respectively. In a major portion of clinical cases, when the field size was smaller than 20${\times}$20 $\textrm{cm}^2$, the tray factor was in good agreement with the standard tray factor. However, in cases where the field sizes were 30${\times}$30 $\textrm{cm}^2$ and 35${\times}$35 $\textrm{cm}^2$, the error could exceed 1.0%. Conclusion:The tray factor increased with increasing field size or decreasing tray thickness. The difference of tray factor between the small field and the large field increased with increasing tray thickness. Furthermore, the standard tray factor was valid in most clinical cases except for when the field size was greater than 30${\times}$30 $\textrm{cm}^2$, wherein the error could exceed 1.0%.

  • PDF

Scalable Collaborative Filtering Technique based on Adaptive Clustering (적응형 군집화 기반 확장 용이한 협업 필터링 기법)

  • Lee, O-Joun;Hong, Min-Sung;Lee, Won-Jin;Lee, Jae-Dong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.2
    • /
    • pp.73-92
    • /
    • 2014
  • An Adaptive Clustering-based Collaborative Filtering Technique was proposed to solve the fundamental problems of collaborative filtering, such as cold-start problems, scalability problems and data sparsity problems. Previous collaborative filtering techniques were carried out according to the recommendations based on the predicted preference of the user to a particular item using a similar item subset and a similar user subset composed based on the preference of users to items. For this reason, if the density of the user preference matrix is low, the reliability of the recommendation system will decrease rapidly. Therefore, the difficulty of creating a similar item subset and similar user subset will be increased. In addition, as the scale of service increases, the time needed to create a similar item subset and similar user subset increases geometrically, and the response time of the recommendation system is then increased. To solve these problems, this paper suggests a collaborative filtering technique that adapts a condition actively to the model and adopts the concepts of a context-based filtering technique. This technique consists of four major methodologies. First, items are made, the users are clustered according their feature vectors, and an inter-cluster preference between each item cluster and user cluster is then assumed. According to this method, the run-time for creating a similar item subset or user subset can be economized, the reliability of a recommendation system can be made higher than that using only the user preference information for creating a similar item subset or similar user subset, and the cold start problem can be partially solved. Second, recommendations are made using the prior composed item and user clusters and inter-cluster preference between each item cluster and user cluster. In this phase, a list of items is made for users by examining the item clusters in the order of the size of the inter-cluster preference of the user cluster, in which the user belongs, and selecting and ranking the items according to the predicted or recorded user preference information. Using this method, the creation of a recommendation model phase bears the highest load of the recommendation system, and it minimizes the load of the recommendation system in run-time. Therefore, the scalability problem and large scale recommendation system can be performed with collaborative filtering, which is highly reliable. Third, the missing user preference information is predicted using the item and user clusters. Using this method, the problem caused by the low density of the user preference matrix can be mitigated. Existing studies on this used an item-based prediction or user-based prediction. In this paper, Hao Ji's idea, which uses both an item-based prediction and user-based prediction, was improved. The reliability of the recommendation service can be improved by combining the predictive values of both techniques by applying the condition of the recommendation model. By predicting the user preference based on the item or user clusters, the time required to predict the user preference can be reduced, and missing user preference in run-time can be predicted. Fourth, the item and user feature vector can be made to learn the following input of the user feedback. This phase applied normalized user feedback to the item and user feature vector. This method can mitigate the problems caused by the use of the concepts of context-based filtering, such as the item and user feature vector based on the user profile and item properties. The problems with using the item and user feature vector are due to the limitation of quantifying the qualitative features of the items and users. Therefore, the elements of the user and item feature vectors are made to match one to one, and if user feedback to a particular item is obtained, it will be applied to the feature vector using the opposite one. Verification of this method was accomplished by comparing the performance with existing hybrid filtering techniques. Two methods were used for verification: MAE(Mean Absolute Error) and response time. Using MAE, this technique was confirmed to improve the reliability of the recommendation system. Using the response time, this technique was found to be suitable for a large scaled recommendation system. This paper suggested an Adaptive Clustering-based Collaborative Filtering Technique with high reliability and low time complexity, but it had some limitations. This technique focused on reducing the time complexity. Hence, an improvement in reliability was not expected. The next topic will be to improve this technique by rule-based filtering.

Determination of Si/Al Ratio of Faujasite-type Zeolite by Single-crystal X-ray Diffraction Technique. Single-crystal Structures of Fully Tl+- and Partially K+-exchanged Zeolites Y (FAU), |Tl71|[Si121Al71O384]-FAU and |K53Na18|[Si121Al71O384]-FAU

  • Seo, Sung-Man;Lee, Oh-Seuk;Kim, Hu-Sik;Bae, Dong-Han;Chun, Ik-Jo;Lim, Woo-Taik
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1675-1682
    • /
    • 2007
  • Large colorless single crystals of faujasite-type zeolite with diameters up to 200 μm have been synthesized from gels with the composition of 3.58SiO2:2.08NaAlO2:7.59NaOH:455H2O:5.06TEA:1.23TCl. Two of these, colorless octahedron about 200 μm in cross-section have been treated with aqueous 0.1 M TlC2H3O2 and KNO3 in order to prepare Tl+- and K+-exchanged faujasite-type zeolites, respectively, and then determined the Si/Al ratio of the zeolite framework. The crystal structures of |Tl71|[Si121Al71O384]-FAU and |K53Na18|[Si121Al71O384]-FAU per unit cell, a = 24.9463(2) and 24.9211(16) A, respectively, dehydrated at 673 K and 1 × 10-6 Torr, have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd m at 294 K. The two single-crystal structures were refined using all intensities to the final error indices (using only the 905 and 429 reflections for which Fo > 4σ(Fo)) R1/R2 = 0.059/0.153 and 0.066/0.290, respectively. In the structure of fully Tl+-exchanged faujasite-type zeolite, 71 Tl+ ions per unit cell are located at four different crystallographic sites. Twenty-nine Tl+ ions fill site I' in the sodalite cavities on 3-fold axes opposite double 6-rings (Tl-O = 2.631(12) A and O-Tl-O = 93.8(4)o). Another 31 Tl+ ions fill site II opposite single 6-rings in the supercage (Tl-O = 2.782(12) A and O-Tl-O = 87.9(4)o). About 3 Tl+ ions are found at site III in the supercage (Tl-O = 2.91(6) and 3.44(3) A), and the remaining 8 occupy another site III (Tl-O = 2.49(5) and 3.06(3) A). In the structure of partially K+-exchanged faujasite-type zeolite, 53 K+ ions per unit cell are found at five different crystallographic sites and 18 Na+ ions per unit cell are found at two different crystallographic sites. The 4 K+ ions are located at site I, the center of the hexagonal prism (K-O = 2.796(8) A and O-K-O = 89.0(3)o). The 10 K+ ions are found at site I' in the sodalite cavity (K-O = 2.570(19) A and O-KO = 99.4(9)o). Twenty-two K+ ions are found at site II in the supercage (K-O = 2.711(9) A and O-K-O = 94.7(3)o). The 5 K+ ions are found at site III deep in the supercage (K-O = 2.90(5) and 3.36(3) A), and 12 K+ ions are found at another site III' (K-O = 2.55(3) and 2.968(18) A). Twelve Na+ ions also lie at site I' (Na-O = 2.292(10) and O-Na-O = 117.5(5)o). The 6 Na+ ions are found at site II in the supercage (Na-O = 2.390(17) A and O-Na-O = 113.1(11)o). The Si/Al ratio of synthetic faujasite-type zeolite is 1.70 determined by the occupations of cations, 71, in two single-crystal structures.

Relationship between Meteorological Factors and Lint Yield of Monoculture Cotton in Mokpo Area (목포지방 기상요인과 단작목화의 생육 및 섬유수량과의 관계)

  • 박희진;김상곤;정동희;권병선;임준택
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.2
    • /
    • pp.142-149
    • /
    • 1995
  • This study was conducted to investigate the relationships between yearly variation of climatic components and yearly variations of productivity in monoculture cotton. In addition, correlation coefficients among yield and yield components were estimated. The data of yield and yield components from the four varieties(Kinggus, Yongdang local. 113-4, 380) were collected from 1978 to 1992 in Mokpo area. The meteorological data gathered at the Mokpo Weather Station for the same period were used to find out the relationships between climatic components and productivity. Yearly variation of the amount of precipitation and number of stormy days in July are large with coefficients of the variations(C.V)84.89 and 97.05%, respectively, while yearly variation, of the average temperature, maximum temperature, minimum temperature from May to Sep. are relatively small. Seed cotton yield before frost in Sep. and Oct. very greatly with C.V. of 68.77, 78.52%, respectively. Number of boll bearing branches and lint percentage show more or less small in C.V. with 11.77 and 19.13%, respectively and flowering date and boll opening date show still less variation. Correlation coefficients between precipitation in May and number of boll bearing branches, duration of sunshine in July and number of bolls per plant, maximum temperature in July and total seed cotton before the frost in Sep., Oct., and Nov. evaporation in Aug. are positively sig-nificant at the 1% level. There are highly significantly positive correlated relationships among yield(total seed cotton) and yield components. Total seed cotton yield(Y) can be predicted by multiple regression equation with independent variables of climatic factors in July such as monthly averages of average temperature($X_1$), maximum temperature($X_2$) and minimum temperature($X_3$), monthly amount of precipitation ($X_4$), evaporation($X_5$), monthly average of relative humidity($X_6$), monthly hours with sunshine($X_7$) and number of rainy days($X_8$). The equation is estimatedas Y =-1080.8515 + 144.7133$X_1$+15.8722$X_2$ + 164.9367$X_3$ + 0.0802$X_4$ + 0.5932$X_5$ + 11.3373$X_6$ + 3.4683$X_7$- 9.0846$X_8$. Also, total seed cotton yield(Y) can be predicted by the same method with climatic components in Aug., Y =2835.2497 + 57.9134$X_1$ - 46.9055$X_2$ - 41.5886X$_3$ + 1.2559$X_5$ - 21.9687$X_6$ - 3.3763$X_7$- 4.1080$X_8$- 17.5586$X_9$. And the error between observed and theoretical yield were less with approached linear regression.

  • PDF

Intercomparison of Shortwave Radiative Transfer Models for a Rayleigh Atmosphere (레일리 대기에서 단파 영역에서의 복사전달모델 결과들의 상호 비교)

  • Yoo, Jung-Moon;Jeong, Myeong-Jae;Lee, Kyu-Tae;Kim, Jhoon;Ho, Chang-Hoi;Ahn, Myoung-Hwan;Hur, Young-Min;Rhee, Ju-Eun;Yoo, Hye-Lim;Chung, Chu-Yong;Shin, In-Chul;Choi, Yong-Sang;Kim, Young Mi
    • Journal of the Korean earth science society
    • /
    • v.28 no.3
    • /
    • pp.298-310
    • /
    • 2007
  • Intercomparison between eight radiative transfer codes used for the studies of COMS (Communications, Ocean, and Meteorological Satellite) in Korea was performed under pure molecular, i.e., Rayleigh atmospheres in four shortwave fluxes: 1) direct solar irradiance at the surface, 2) diffuse irradiance at the surface, 3) diffuse upward flux at the surface, and 4) diffuse upward flux at the top of the atmosphere. The result (hereafter called the H15) from Halthore et al.'s study (2005) which intercompared and averaged 15 codes was used as a benchmark to examine the COMS models. Uncertainty of the seven COMS models except STREAMER was ${\pm}4%$ with respect to the H15, comparable with ${\pm}3%$ of Halthore et al.'s (2005). The uncertainty increased under a large $SZA=75^{\circ}$. The SBDART model generally agreed with the H15 better than the 6S model, but both models in the shortwave infrared region were equally good. The direct solar irradiance fluxes at the surface, computed by the SBDARTs of four different users, were different showing a relative error of 1.4% $(12.1Wm^{-2})$. This reason was partially due to differently installing the wavelength resolution in the flux integration. This study may be useful for selecting the optimum model in the shortwave region.

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.

DISEASE DIAGNOSED AND DESCRIBED BY NIRS

  • Tsenkova, Roumiana N.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1031-1031
    • /
    • 2001
  • The mammary gland is made up of remarkably sensitive tissue, which has the capability of producing a large volume of secretion, milk, under normal or healthy conditions. When bacteria enter the gland and establish an infection (mastitis), inflammation is initiated accompanied by an influx of white cells from the blood stream, by altered secretory function, and changes in the volume and composition of secretion. Cell numbers in milk are closely associated with inflammation and udder health. These somatic cell counts (SCC) are accepted as the international standard measurement of milk quality in dairy and for mastitis diagnosis. NIR Spectra of unhomogenized composite milk samples from 14 cows (healthy and mastitic), 7days after parturition and during the next 30 days of lactation were measured. Different multivariate analysis techniques were used to diagnose the disease at very early stage and determine how the spectral properties of milk vary with its composition and animal health. PLS model for prediction of somatic cell count (SCC) based on NIR milk spectra was made. The best accuracy of determination for the 1100-2500nm range was found using smoothed absorbance data and 10 PLS factors. The standard error of prediction for independent validation set of samples was 0.382, correlation coefficient 0.854 and the variation coefficient 7.63%. It has been found that SCC determination by NIR milk spectra was indirect and based on the related changes in milk composition. From the spectral changes, we learned that when mastitis occurred, the most significant factors that simultaneously influenced milk spectra were alteration of milk proteins and changes in ionic concentration of milk. It was consistent with the results we obtained further when applied 2DCOS. Two-dimensional correlation analysis of NIR milk spectra was done to assess the changes in milk composition, which occur when somatic cell count (SCC) levels vary. The synchronous correlation map revealed that when SCC increases, protein levels increase while water and lactose levels decrease. Results from the analysis of the asynchronous plot indicated that changes in water and fat absorptions occur before other milk components. In addition, the technique was used to assess the changes in milk during a period when SCC levels do not vary appreciably. Results indicated that milk components are in equilibrium and no appreciable change in a given component was seen with respect to another. This was found in both healthy and mastitic animals. However, milk components were found to vary with SCC content regardless of the range considered. This important finding demonstrates that 2-D correlation analysis may be used to track even subtle changes in milk composition in individual cows. To find out the right threshold for SCC when used for mastitis diagnosis at cow level, classification of milk samples was performed using soft independent modeling of class analogy (SIMCA) and different spectral data pretreatment. Two levels of SCC - 200 000 cells/$m\ell$ and 300 000 cells/$m\ell$, respectively, were set up and compared as thresholds to discriminate between healthy and mastitic cows. The best detection accuracy was found with 200 000 cells/$m\ell$ as threshold for mastitis and smoothed absorbance data: - 98% of the milk samples in the calibration set and 87% of the samples in the independent test set were correctly classified. When the spectral information was studied it was found that the successful mastitis diagnosis was based on reviling the spectral changes related to the corresponding changes in milk composition. NIRS combined with different ways of spectral data ruining can provide faster and nondestructive alternative to current methods for mastitis diagnosis and a new inside into disease understanding at molecular level.

  • PDF

Two Crystal Structures of Bromine Sorption Complexes of Vacuum Dehydrsted Fully Cd(II) -Exchanged Zeolite A (카드뮴 이온으로 완전히 치환된 제올라이트 A를 진공 탈수한 후 브롬 증기로 흡착한 두개의 결정구조)

  • 고광락;장세복
    • Korean Journal of Crystallography
    • /
    • v.3 no.1
    • /
    • pp.9-22
    • /
    • 1992
  • Two crystal structures of bromine sorption complexes of vacuum dehydrated Cd(ll)-exchanged zeolite A have been determined by single-crystal xray diffraction techniques in the cubic space group Pm3m at 21(1) ℃. Both crystals were ion exchanged in flowing streams of exchange solution In which mole ratio of Cd(NO3)2 and Cd(OOCCH3)B was 1:1 with a total concentration of 0.05 M. First crystal was dehydrated at 450℃ and 2 ×10-6 Torr for two days. Second crystal was dehydrated at 650℃ and 2 ×10-6 Torr for two days. Both crystals were then treated with 160 Torr for two days. Second crystal was dehydrated at 650℃ and 2 × 10-6 Torr for two days. Both crystals were then treated with 160 Torr of zeolitically dried bromine vapor at 24℃. Full-matrix least-squares refinements of toe first crystal(a: 12.250(1) A )· and the second crystal(a: 12.204(2) A ) have contecoed to final error indices, Rl:0.075 and Ra:0.079 with 212 reflections, and Rl : 0.089 and Ra = 0.078 with 128 reflections, respectively, for which I >3σ(I). Crystallographic analyses of both crystals show that six Cd2+ ions are located on two different threefold axes of unit cell associated with 6-ring oxygens. Each 4.5 Cd2+ ion is recessed ca.0. 441 A Into the large cavity to complex either with Brsor with Br3from the (111) plane of 0(3), whereas each 1.5 Cd2+ ions recessed ca. 0.678 A into we sodalite unit. Approximately 1.5 Br5-and 1.5 Br3-ions are sorbed per unit cell. Each Brsion interacts and stabilized by complexing with two Cd2+ ions and framework oxide ions, while each Br3ion interacts with one Cd2+ ion and framework oxide ions. Because of residual water molecules the following reactions may be occurred inside of zeolite cavity:

  • PDF