• Title/Summary/Keyword: large deviation rate

Search Result 99, Processing Time 0.023 seconds

ON THE CURIE-WEISS MODEL WITH A NEW HAMILTONIAN

  • Lee, Sang Ho
    • Korean Journal of Mathematics
    • /
    • v.7 no.2
    • /
    • pp.301-313
    • /
    • 1999
  • In this paper we obtain similar limit theorems of the Generalized Curie - Weiss model for a new class Hamiltonian. We expressed the saddlepoint approximation by large deviation rate and then obtain the limit theorems.

  • PDF

A study on the characteristics of hydraulic automatic gauge control system for a reversing cold mill (유압압하식 자동두께제어장치의 특성에 관한 연구)

  • Kim, Soon Kyung;Jeon, Eon Chan;Kim, Moon Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.3
    • /
    • pp.49-55
    • /
    • 1996
  • Recently, the necessity for more accurate automatic gauge control has increased of customers' requirement for cold rolled steel sheets with thinner gauge and better gauge quality. Therefore, many cold rolling mills replaced its electric screw down automatic gauge control system with a new hydraulic automatic gauge control system, to ensure closer gauge tolerance. In this paper, The performance of a hydraulic automatic gauge control system for cold rolling has been investigated under industrial conditions. It was investigated that variation of gauge deviation according to the final products thickness, cold rolling speed and pass number, in the actual rolling mill. As a result, it was found that the system enables strip thickness variation to be reduced substantially and caused by poor gauge deviation have been drastically decreased. The test results are as following. The more the exit steel strip thickness is thick, the smaller the aguge deviation rate is large, and the more it is thin, the large the gauge deviation rate is large. Because the gauge deviation is larger at accleration speed and deceleration speed than steady speed, so automatic gauge control system is better to adopt over 50m/min. automatic gauge control system reduces rapidly large thickness deviation.

  • PDF

A Study on the Hydraulic Automatic Gauge Control System of Adaptive Mass Flow Method (Adaptive mass flow method 유압압하식 자동 두께제어 장치에 관한 연구)

  • 윤순현;김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.101-107
    • /
    • 1996
  • This test was performed on the hydraulic automatic gauge control(AGC) system of adaptive mass flow method. Fundamental purpose of this study are performance evaluation of this AGC system under the actual rolling condition. It was concluded that the response of AGC system depends on the dynamic characteristics of a reel motor or roll position. The test results are as follows : 1) The control method of reel motor current is better than than of the roll position as AGC system. 2) The more steel strip thickness of delivery side is thick, the larger the gauge deviation is large, and the more it is thin, the larger the gauge deviation rate is large. 3) Because the gauge deviation is large at acceleration and deceleration speed than steady speed, so AGC system is better to adopt over 50m/min. By applying this AGC system, not only the accurary in strip thickness were improved but also productivity was improved dramatically.

  • PDF

Asymptotic Gaussian Structures in a Critical Generalized Curie-Wiss Mean Field Model : Large Deviation Approach

  • Kim, Chi-Yong;Jeon, Jong-Woo
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.4
    • /
    • pp.515-527
    • /
    • 1996
  • It has been known for mean field models that the limiting distribution reflecting the asymptotic behavior of the system is non-Gaussian at the critical state. Recently, however, Papangelow showed for the critical Curie-Weiss mean field model that there exist Gaussian structures in the asymptotic behavior of the total magnetization. We construct Gaussian structures existing in the internal fluctuation of the system for the critical case of a generalized Curie-Weiss mean field model.

  • PDF

A Study on Error Characteristics of Large Size Electromagnetic Flowmeter in the Range of Low Velocity (저유속 영역에서 대구경 전자기유량계의 오차특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • The large size electromagnetic flowmeter was tested to investigate the variation of its error characteristics in the range of low velocity under 0.6 m/s using flowmeter calibration system. For the two case of valve opening rate 100 % and 50 %, these tests were undertaken three times each for twelve velocity condition from $0.05\;^m/s\;to\;0.6\;^m/s$ with increment of $0.05\;^m/s$. It is shown that error characteristic of electromagnetic flowmeter was stabilized within ${\pm}0.4%$ of rate both higher than $0.25^m/s$ of velocity condition and 50 % of valve opening position. But, measurement deviation of flowmeter for ${\Phi}400mm\;and\;{\Phi}600mm$ was out of expected deviation range. It is necessary to correction with calibration. In conclusion, error characteristic of electromagnetic flowmeter wasn't changed proportion to its size.

LIMIT THEOREMS FOR HAWKES PROCESSES WITH UNIFORM IMMIGRANTS

  • Seol, Youngsoo
    • Journal of the Korean Mathematical Society
    • /
    • v.56 no.4
    • /
    • pp.935-946
    • /
    • 2019
  • Hawkes process is a self-exciting simple point process with clustering effect whose jump rate depends on its entire past history. We consider Hawkes processes with uniform immigrants which is a special case of the Hawkes processes with renewal immigrants. We study the limit theorems for Hawkes processes with uniform immigrants. In particular, we obtain a law of large number, a central limit theorem, and a large deviation principle.

Development of a New Water Circulating System for Hot Water Mattress Without Water Pump (새로운 펌프 없는 온수매트용 온수 순환 시스템의 개발)

  • Je, Jong Joo;Sohn, Chang Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1031-1036
    • /
    • 2013
  • The motor-driven water pump boiler for a water circulating mattress generates noise and vibration as it supplies a large water flow rate. A non-pump boiler can reduce such noise and vibration, however, the water circulation flow rate becomes lesser than that in motor-driven water pump boilers, and a large temperature deviation occurs between the inlet and the outlet of the mattress. In this research, a new non-pump boiler for water circulating mattress is developed and its performance is experimentally validated and compared with the existing non-pump boilers. The experimental results show that temperature response time is improved and temperature deviation is reduced.

Inter-comparison of Bell Prover using Sonic Nozzles (소닉노즐을 이용한 벨 푸루버의 국제비교)

  • Choi, Hae Man;Park, Kyung-Am
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.24-29
    • /
    • 2004
  • The inter-comparison of standards is required to be recognized the calibration results. The sonic nozzle package is developed to do inter-comparison of the bell preyer used to calibrate many gas flow meters for industries. Four national metrology institutes (KRISS, CMS, CENAM, NEL) were participated in this inter-comparison. The deviation of calibration data from the average value was small at the low flow rate and large at the high flow rate, respectively At the high flow rate, the deviation was larger than the expected value from uncertainties asserted by NMIs. This means there are some problems in the uncertainty evaluation and experiment procedures in some of the participated NMIs.