• 제목/요약/키워드: lapped splice

검색결과 12건 처리시간 0.03초

SD500철근 커플러 이음의 편익/비용분석에 관한 연구 (A Study on Benefit/Cost Analysis of Re-Bar Connection Methods for Hyper Strength(SD500) Reinforcement)

  • 김재엽;권여울;김준영
    • 한국건축시공학회지
    • /
    • 제8권2호
    • /
    • pp.81-87
    • /
    • 2008
  • High-rise building is taking a place as one of building types from apartment housings to commercial buildings. With taking in account of stability and durability, strength of used materials is increasing gradually in these high-rise buildings. According to this, frequency in use of SD500 re-bar is increasing gradually in high-rise buildings. However the study of SD500 re-bar is insufficient because SD500 re-bar started to be used for domestic buildings lately. Specially because there is no guide or study to refer to, people get into difficulties when to decide the method of re-bar connection in construction using SD500 re-bar. Accordingly in this study, it suggests the method of estimating the economical efficiency on SD500 re-bar connection, and conducts benefit/ cost analysis on lapped splice and coupler splice by applying AHP theory, and then presents its result. After to analyze re-bar diameter of D25, 29, and 32, finally we attained the result that the coupler splice is advantageous in all parts of benefit/ cost more than the lapped splice.

콘크리트 강도변화에 따른 D22mm 철근의 압축이음 성능 평가 (An evaluation of compressive lap splice of the D22 rebar by concrete strengths)

  • 이성호;천성철;오보환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1081-1084
    • /
    • 2008
  • 고강도 콘크리트의 적용 확대에 반해, 현행 철근의 정착 및 이음 산정식은 70MPa 미만의 콘크리트로 한정되어 있으며, 50MPa 이상에서는 압축이음길이가 인장이음보다 길어지는 현상이 발생하는 등 관련 기술이 미비한 상태이다. 본 연구에서는 고강도 콘크리트에서 콘크리트 압축강도, 철근간격, 직교방향 보강 철근의 위치와 보강량에 따른 철근 압축이음내력 특성을 평가하였다. 압축이음된 22mm 철근을 주근으로 가지는 총 64개의 기둥 실험체를 제작하여, 단조 일축 압축 하중을 파괴 시 까지 재하하여 실험을 수행하였다. 실험결과 콘크리트의 압축강도, 압축 이음 길이, 철근간격 및 직교방향 보강 철근 등이 철근의 압축이음 내력을 결정하는 주요한 요소로 작용하는 것으로 분석되었다.

  • PDF

수직으로 비접촉 겹침이음된 철근의 이음성능에 관한 해석적 연구 (Analytical Study on Splice Performances with the Vertical Noncontact Lapped of Reinforcing Bars)

  • 이호진;김승훈;하상수;문정호;이리형;이용택
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.171-174
    • /
    • 2005
  • In this study, new moment-resisting precast concrete beam-column joint is proposed for moderate seismic regions. It has the connection reinforcing bars, penetrated the joint and lap-spliced with the bottom bars of precast U-beam. To evaluate the performance for noncontact lapped splice, analytical works were conducted. Major variables for FEM analysis are the length of lap, the diameter of connection reinforcing bars, and the distance between lapped bars. The results of this study show thar the these variables has much influence on strength and deformation of lapped joint.

  • PDF

비접촉 겹침 이음된 프리캐스트 U형 보의 휨성능에 미치는 효과 (Effect of Flexural Performance on U-Shaped Precast Concrete Beams with Noncontact Lapped Splice)

  • 하상수;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.119-128
    • /
    • 2008
  • 본 연구는 중진지역에서의 PC(precast conctete) 보-기둥 접합부의 새로운 모멘트-저항 시스템을 제안하는 것이다. 철근 이음형 접합부에서 연결재는 접합부를 관통하고, U형 하프 PC 보의 하부철근과 비접촉 겹칩이음으로 연결되어 있다. 비접촉 겹침이음에 대한 성능을 파악하기 위하여 실험적 연구와 해석적 연구가 수행되었다. 실험의 주요변수는 겹침길이, 연결재의 크기, 그리고 겹침이음된 연결재의 거리 등이다. 또한, 균열양상, 하중-변위 곡선, 내력 비교, 그리고 연결재의 변형 등에 초점을 맞추어 해석적 연구를 수행하여 실험결과와 비교하였다. 해석과 실험 결과 주요변수인 겹침길이, 연결재의 크기, 연결재의 비접촉 수직 거리등에 따라 강도, 연성, 그리고 접합부 거동에 큰 영향을 주는 것으로 나타났다.

고강도 콘크리트 구조물의 철근 부착 및 이음에 대한 연구 (Bond & Lapped Splices in High-Strength Concrete Structures)

  • 김준성
    • 한국농공학회지
    • /
    • 제39권6호
    • /
    • pp.122-130
    • /
    • 1997
  • An experimental study was conducted to evaluate the bond performance of reinforcing bars embedded in high-strength concrete. Four bond specimens and ten beam splice specimens using concrete with compressive strength of 246kgf/$cm^2$ and 64lkgf/$cm^2$ were tested. The effect of several variables on basic development length and compressive strength of concrete is discussed in splice specimens. The test results showed that the current trend in concrete specification of making the splice length longer to compensate for having smaller cover and spacing may not be an effective approach.

  • PDF

인장철근의 겹침이음에서 횡보강근의 효과에 관한 실험적 연구 (An Experimental Study on Effects Transverse Reinforcement in Lap-Spliced Tension Reinforcing Bars)

  • 이호준;최선아;연규원;박찬수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.879-884
    • /
    • 2000
  • In this study, an experimental work is conducted to evaluate the bond performance between reinforcing bars and surrounding concrete in a lapped splice. The major variable of this test is a transverse reinforcement in lap-spliced tension reinforcing bars. The test results indicate that the bond strength per unit splice length increases with an increase in the transverse reinforcement factor $K_{\alpha}$. The specimens taken less than (c+$K_{tr}$)/$d_b$=3.0 tend to be very brittle at failure. But the specimens taken longer than (c+$K_{tr}$)/$d_b$=3.0 tend to be somewhat ductile at failure.

결속선이 R/C보의 거동에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effect of Tie-wire on R/C Beam Behaviors)

  • 변항룡;공귀옥;김준성;이수곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.737-742
    • /
    • 1997
  • In this paper the effect of tie wire in lap spliced bars is investigated by experiment. The variables considered in the beam behaviors are beam dimension, lapped splice length and numbers of tie wire. 3 test pieces having the same variables consist one series and a total of 6 series ar tested. The test results show the beam behavior is not affected by numbers of tie wire but by the manner of tie. It was revealed hat the load bearing capacity of the beam is increased when the tie wire is extended to top bar.

  • PDF

고강도 콘크리트 휨 부재의 철근 겹이음에 대한 연구 (Lapped Splices in High-Strength Concrete Flexural Members)

  • 김우;김준성;김대중;손영현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.447-452
    • /
    • 1996
  • An experimental study was conducted to evaluate the bond performance of reinforcing bars embedded in high-strength concrete. Ten beam spice Specimens using concrete with compressive strength of 240kg/$\textrm{cm}^2$ and 640kg/$\textrm{cm}^2$ were tested. The effect of several variables on basic development length is discussed. The test results showed that the current trend in concrete specification of making the splice length longer to compensate for having smaller cover and spacing may not be an effective approach.

  • PDF

가스압접 이형철근의 기계적 강도 특성 연구 (A Study on the Mechanical Properties of Gas Pressure Welded Splices of Deformed Reinforcing Bar)

  • Jeon, Juntai
    • 한국재난정보학회 논문집
    • /
    • 제11권4호
    • /
    • pp.520-526
    • /
    • 2015
  • 철근 콘크리트 구조에서 철근의 이음은 불가피하게 사용된다. 최근 들어 철근 콘크리트 구조물에 가장 많이 사용되고 있는 철근 이음에는 겹침 이음, 기계 이음, 그리고 용접 접합 등이 있다. 이중에서 저비용, 건설 현장에서의 실용성, 공사 기간 단축 및 고성능 등의 장점으로 인하여 가스 압접 이음의 효용성이 대두되고 있다. 그러나 가스 압접 이음 과정동안 철근이 열을 받게 되고 이는 접합부 주위에 잔류 응력으로 남아 철근의 피로수명에 영향을 미칠 수 있다. 그러므로 가스 압접 접합부의 명확한 잔류 응력 분석과 가스 압접 후 철근의 하중지지 능력을 확인하기 위한 인장 시험이 수행되어야 한다. 이 연구에서는 공용중인 철근(KS D3504 SD400)에 대하여 3차원 해석을 수행하여 연구 결과 잔류 응력은 상대적으로 작기 때문에 철근의 피로 수명에 영향을 미치지 않으며 인장 실험 결과에서도 가스 압접된 철근의 항복강도가 기준항복강도보다 높게 측정되어 하중 저항 능력도 가스 압접 이음부가 연속된 철근으로서의 거동에 충분히 그 성능을 발휘하는 것으로 나타났다.

단부에 Interlocking Spiral을 가진 전단벽의 거동에 관한 연구 (Study for the Structural walls with Interlocking Spirals on the boundary)

  • 홍성걸;김록배;정하선;구광현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.865-870
    • /
    • 2001
  • This paper propose a new seismic detail for ductility enhancement by interlocking spiral reinforcement in the potential yield regions of a wall. Through the theoretical consideration and experiment program, confinement with interlocking spirals lead the structural walls to ductile behavior. All specimens show stable hysteretic behavior and good energy dissipation capacity. Also the increase of shear strength mainly induces a flexural failure mode. As interlocking spiral are used in lapped splice region, they increase the bond strength and prevent a early tensile failure caused by the loss of bond stresses. Consequently, the confinement with interlocking spirals may result in a lower value of force reductions factor, newly proposed detail will be provide more economical design.

  • PDF