• 제목/요약/키워드: laboratory medical testing

검색결과 203건 처리시간 0.03초

인플루엔자 관련 뇌증 1례 (A Case of Influenza-associated Encephalopathy)

  • 송연이;최창환;최종운;김세영;김현수;김열;임동진
    • Clinical and Experimental Pediatrics
    • /
    • 제46권10호
    • /
    • pp.1024-1028
    • /
    • 2003
  • 저자들은 인플루엔자 유행시기에, 생후 3년 1개월 환아에서 갑작스런 고열을 동반한 경련 발작과 의식소실을 주소로, 6일간 입원 치료에도 불구하고 급격한 급성 뇌증의 악화와 간기능수치 증가 및 신장기능 부전, 범발성 혈관내 응고증으로 사망한 남아에서 인플루엔자 바이러스 항체 검사상 A/H1N1에 대한 HI titer가 초 회 항체 역가의 4배 이상 증가됨을 관찰하여 국내에는 보고된 예가 없는 급성 인플루엔자 뇌증으로 진단한 1례를 경험하였기에 문헌 고찰과 함께 보고하는 바이다.

Primary Immunodeficiencies in Children Initially Admitted with Gastrointestinal/Liver Manifestations

  • Murat Cakir ;Nalan Yakici ;Elif Sag ;Gulay Kaya ;Aysenur Bahadir;Alper Han Cebi ;Fazil Orhan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제26권4호
    • /
    • pp.201-212
    • /
    • 2023
  • Purpose: The gastrointestinal system is the most commonly affected organ, followed by the lungs, in patients with primary immunodeficiency disease (PID). Hence, it is common for children with PIDs to present with gastrointestinal symptoms. We aimed to analyze the clinical and histopathological findings of patients who were initially admitted to pediatric gastroenterology/hepatology clinics and subsequently diagnosed with PIDs to identify the clinical clues for PIDs. Methods: The demographic, laboratory, and histopathological findings, treatment modality, and outcomes of patients initially admitted to the pediatric gastroenterology/hepatology unit and subsequently diagnosed with PIDs were recorded. Results: The study included 24 patients (58.3% male; median age [range]: 29 [0.5-204] months). Common clinical presentations included chronic diarrhea (n=8), colitis (n=6), acute hepatitis (n=4), and acute liver failure (n=2). The association of autoimmune diseases, development of malignant diseases, and severe progression of viral diseases was observed in 20.8%, 8.3%, and 16.6% of the patients, respectively. Antibody deficiency was predominantly diagnosed in 29.2% of patients, combined immunodeficiency in 20.8%, immune dysregulation in 12.5%, defects in intrinsic and innate immunity in 4.2%, autoinflammatory disorders in 8.3%, and congenital defects of phagocytes in 4.2%. Five patients remained unclassified (20.8%). Conclusion: Patients with PIDs may initially experience gastrointestinal or liver problems. It is recommended that the association of autoimmune or malignant diseases or severe progression of viral diseases provide pediatric gastroenterologists some suspicion of PIDs. After screening using basic laboratory tests, genetic analysis is mandatory for a definitive diagnosis.

제안제도를 활용한 RIA 발전 방향에 관한 연구 (The Study of RIA Development Direction using Suggestion System)

  • 신영균;천준홍;김년옥;이선호;김성호;유선희
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.106-112
    • /
    • 2011
  • 기존에는 제안 내용을 검사 담당자가 필요에 의해 개인적으로 process개선을 하였다. 그러나 최근 병원에서 정책적으로 제안제도 활성화를 다양한 방법으로 추진하고 있어 핵의학과 혈액검사실에서도 체계적인 system이 대두 되었다. 이에 핵의학과 혈액검사실에도 제안제도를 활용하여 업무개선이 활성화 되었고 더 나아가 우수제안 사례를 타 병원과 공유하여 RIA 발전에 도움을 추구하고자 한다. 2007년 1월부터 2010년 3월까지 혈액검사실에서 제안한 총 124건의 제안내용을 분석하였다. 연구방법은 제안한 내용을 고객만족, 원가절감, 실험 방법개선, 장비, 환경개선, 전산 등으로 나누어 분석 하였다. 총 124건의 제안 내용 중 환경개선과 전산에 관한 제안이 각 33건씩으로 26.6%를 차지하였고, 고객만족에 관한 제안이 32건으로 약 25.8%를 차지 하였다. 그 중 우수제안 내용은 다음과 같다. 1. RIA-MAT280(핵의학 혈액검사 자동화 기기) washing part 소모품 제작에 따른 기기운용 효율성 증진 및 원가절감 방안 2. Fitting system을 이용한 aspiration line의 개선 및 유지보수 개선방안 3. 자동분주기기(automatic dispensing system, Hamilton) waste bottle cap개조를 통한 액체 폐액 관리 개선방안 4. Hamilton System을 이용한 검사용 검체 분주 시 error방지를 위한 개선방안 5. Air regulator를 이용한 측정성분 dry개선방안 6. 검사코드 순서 배열 수정에 의한 건별결과 입력 error 감소 방안 7. 접수시간 스티커 발행으로 재검사 수행할 모 검체 찾는 시간 단축방안 8. Hamilton 장비 QC 보안으로 정확도 향상 제안제도를 통해 관리자부터 검사실 직원에 이르는 업무개선 의식의 활성화를 유도하고, 전사적인 업무개선 시스템을 확보함으로써 일반직원에게도 아이디어의 생산 및 체계화를 유도할 수 있었으며, 나아가 실질적인 업무개선 효과를 통해 병원경쟁력을 높이고 병원 발전을 도모 하였다.

  • PDF

Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

  • Kang, Suk-Hyung;Cho, Yong Jun;Kim, Young-Baeg;Park, Seung Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권4호
    • /
    • pp.229-234
    • /
    • 2015
  • Objective : Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step of a range of complications. The authors recently used a modified transpedicular polymethylmethacrylate (PMMA) screw augmentation technique to overcome pedicle screw loosening. Here, they report on the laboratory testing of pedicle screws inserted using this modified technique. Methods : To evaluate pullout strengths three cadaveric spinal columns were used. Three pedicle screw insertion methods were utilized to compare pullout strength; the three methods used were; control (C), traditional transpedicular PMMA augmentation technique (T), and the modified transpedicular augmentation technique (M). After control screws had been pulled out, loosening with instrument was made. Screw augmentations were executed and screw pullout strength was rechecked. Results : Pedicle screws augmented using the modified technique for pedicle screw loosening had higher pullout strengths than the control ($1106.2{\pm}458.0N$ vs. $741.2{\pm}269.5N$; p=0.001). Traditional transpedicular augmentation achieved a mean pullout strength similar to that of the control group ($657.5{\pm}172.3N$ vs. $724.5{\pm}234.4N$; p=0.537). The modified technique had higher strength than the traditional PMMA augmentation technique ($1070.8{\pm}358.6N$ vs. $652.2{\pm}185.5N$; p=0.023). Conclusion : The modified PMMA transpedicular screw augmentation technique is a straightforward, effective surgical procedure for treating pedicle screw loosening, and exhibits greater pullout strength than traditional PMMA transpedicular augmentation. However, long-term clinical evaluation is required.

The effect of resin cement type and cleaning method on the shear bond strength of resin cements for recementing restorations

  • Koodaryan, Roodabeh;Hafezeqoran, Ali;Maleki, Amin Khakpour
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.110-117
    • /
    • 2017
  • PURPOSE. This laboratory study assessed the effect of different dentin cleaning procedures on shear bond strength of resin cements for recementing prosthesis. MATERIALS AND METHODS. A $4{\times}4$ flat surface was prepared on the labial surface of 52 maxillary central incisors. Metal frames ($4{\times}4{\times}1.5mm$) were cast with nickel-chromium alloy. All specimens were randomly divided into 2 groups to be cemented with either Panavia F2.0 (P) or RelyX Ultimate (U) cement. The initial shear bond strength was recorded by Universal Testing Machine at a crosshead speed of 0.5 mm/min. Debonded specimens were randomly allocated into 2 subgroups (n = 13) according to the dentin cleaning procedures for recementation. The residual cement on bonded dentin surfaces was eliminated with either pumice slurry (p) or tungsten carbide bur (c). The restorations were rebonded with the same cement and were subjected to shear test. Data failed the normality test (P < .05), thus were analyzed with Mann Whitney U-test, Wilcoxon signed rank test, and two-way ANOVA after logarithmic transformation (${\alpha}=.05$). RESULTS. The initial shear bond strength of group P was significantly higher than group U (P = .001). Pc and Uc groups presented higher bond strength after recementation compared to the initial bond strength. However, it was significant only in Pc group (P = .034). CONCLUSION. The specimens recemented with Panavia F2.0 provided higher bond strength than RelyX Ultimate cement. Moreover, a tungsten carbide bur was a more efficient method in removing the residual resin cement and increased the bond strength of Panavia F2.0 cement after recementation.

Study on a Single-Dose Toxicity Test of D-Amino Acid Oxidase (DAAO) Extracts Injected into the Tail Vein of Rats

  • Kang, Jungue;Lee, Eun-Yong;Song, Bong-Keun;Lee, Seung-Deok;Yook, Tae-Han;Ahn, Seong-Hun;Son, Il-Hong;Kim, Sungchul
    • 대한약침학회지
    • /
    • 제16권2호
    • /
    • pp.28-32
    • /
    • 2013
  • Objective: This study was performed to analyze the single-dose toxicity of D-amino acid oxidase (DAAO) extracts. Methods: All experiments were conducted at the Korea Testing & Research Institute (KTR), an institution authorized to perform non-clinical studies, under the regulations of Good Laboratory Practice (GLP). Sprague-Dawley rats were chosen for the pilot study. Doses of DAAO extracts, 0.1 to 0.3 cc, were administered to the experimental group, and the same doses of normal saline solution were administered to the control group. This study was conducted under the approval of the Institutional Animal Ethics Committee. Results: In all 4 groups, no deaths occurred, and the $LD_{50}$ of DAAO extracts administered by IV was over 0.3 ml/kg. No significant changes in the weight between the control group and the experimental group were observed. To check for abnormalities in organs and tissues, we used microscopy to examine representative histological sections of each specified organ, the results showed no significant differences in any organs or tissues. Conclusion: The above findings suggest that treatment with D-amino acid oxidase extracts is relatively safe. Further studies on this subject should be conducted to yield more concrete evidence.

혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석 (Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test)

  • 박미숙;박경순;김경아;차영주;전명희;김태임;;차은종
    • 한국간호교육학회지
    • /
    • 제12권2호
    • /
    • pp.265-271
    • /
    • 2006
  • Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.

  • PDF

최근 5년간 국내 소아청소년에서 분리된 Haemophilus influenzae의 항생제 감수성 분석 (Trend of Antibiotic Susceptibility of Haemophilus influenzae Isolated from Children, 2014-2019)

  • 이은택;박세라;김미나;이진아
    • Pediatric Infection and Vaccine
    • /
    • 제27권3호
    • /
    • pp.147-157
    • /
    • 2020
  • 목적: 최근 β-lactam 계 항생제에 대한 내성을 보이는 Haemophilus influenzae가 증가하고 있다. 본 연구는 최근 5년간 서울아산병원 어린이 병원에서 분리된 H. influenzae 균주의 항생제 내성 양상을 분석하고자 한다. 방법: 2014년 3월부터 2019년 4월까지 서울아산병원 어린이병원을 내원한 18세 미만의 소아청소년 환자의 임상 검체에서 분리된 H. influenzae 균주를 대상으로 항생제 내성 양상을 분석하였다. 결과: 최근 5년간 총 69례의 H. influenzae가 분리되었으며 이들 환자의 연령 중앙값은 5.0 (2.8-8.6)세였다. 총 69례 중 3례(4.3%)가 혈액 배양에서 분리되었으며, 66례(95.7%)가 비침습성 균주로서 대부분 호흡기 검체(59례)에서 분리되었다. 항생제 감수성 분포는 ampicillin (AMP) 감수성/amoxicillin-clavulanate (AMC) 감수성 균주 15례(21.7%), AMP 내성/AMC 감수성 21례(30.4%), AMP 내성/AMC 내성 33례(47.8%)였으며, 최근 5년에 걸쳐 AMP 내성/AMC 내성 균주는 지속적으로 증가하는 경향을 보였다 (2014-2015: 42.1% [8/19], 2016-2017: 46.4% [13/28], 2018-2019: 54.5% [12/22], P for trend=0.342). 2014-2015년에 비해 2018-2019년 기간에는 cefuroxime과 ceftriaxone에 대한 내성률은 각각 31.6%에서 77.3% 및 0.0% 에서 59.1% 로 유의하게 증가하였다(P for trend 0.003 및 <0.001). 결론: 최근 국내의 3차 의료기관에 입원한 소아에서 분리되는 H. influenzae 균주는 AMP및 AMC에 대해 모두 내성인 경우가 흔하며, cefuroxime 및 ceftriaxone 에 대한 내성률이 유의하게 증가하였다. 이러한 균주의 내성 기전 분석과 함께 이의 출현과 확산을 최소화하기 위한 노력이 필수적이다.

선별 검사를 위한 탁상용 폐활량기 (HI-801)의 임상적 유용성에 관한 고찰 (Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening)

  • 최혜숙;최천웅;박명재;강홍모;유지홍
    • Tuberculosis and Respiratory Diseases
    • /
    • 제62권4호
    • /
    • pp.276-283
    • /
    • 2007
  • 연구배경: 폐활량 검사는 간단하고 저렴한 폐질환의 선별 검사방법으로 흡연자나 호흡기 증상이 있는 환자에게 폐질환의 조기 발견을 위한 선별검사로 권고되고 있으며, 이에 따라 간단하고 저렴한 탁상용 폐활량 기기들이 공급되고 있다. 본 연구의 목적은 환기장애 소견을 보인 환자를 대상으로 탁상용 폐활량기와 병원 폐기능 검사실의 폐활량기의 폐활량 측정값을 비교 분석하여 그 일치도를 알아보고 이를 통해 탁상용 폐활량기의 임상환경에서의 정확성과 두 기기간의 임상적 상호 대체 허용성을 알아보고자 하였다. 방법: 2006년 4월부터 2006년 9월까지 경희의료원 건강검진 센터에서 HI-801기로 폐활량검사를 시행한 사람들 중 환기장애 소견을 보인 환자를 대상으로 폐기능 검사실에서 Vmax spectra 22d 폐활량기로 재검사를 시행하였다. 결과: 총 109명의 환자가 참여하였으며, 이 중 남자가 70명(64.2%)이었다. HI-801 기와 Vmax spectra 22d기로 측정한 폐활량 값들은 각각 FVC($3.03{\pm}0.62$ vs. $3.38{\pm}0.67L$), $FEV_1$($2.44{\pm}0.57$ vs. $2.61{\pm}0.58L$), PEFR($5.83{\pm}2.01$ vs. $7.70{\pm}2.11L/s$), FET($5.12{\pm}1.71$ vs. $6.68{\pm}1.11sec$), $FEF_{25%-75%}$($2.61{\pm}1.09$ vs. $2.48{\pm}1.08L/s$)였다. 두 기기간의 FVC, $FEV_1$, PEFR, $FEF_{25%-75%}$ 측정값의 상관 계수는 각각 r= 0.93, 0.94, 0.81, 0.84였으며, FVC, $FEV_1$은 Bland and Altman plot에서 95% 신뢰구간의 일치도 제한에서 각각 4%, 5% 만이 ${\pm}1.96SD$ 밖에 위치하였다. 결론: 탁상용 폐활량기인 HI-801 기는 병원 폐기능 검사실 Vmax spectra 22d 기와의 비교에서 높은 상관관계와 좋은 일치도를 보여, 탁상용 HI-801 기의 정확성을 알 수 있었으며, HI-801로 측정한 FVC, $FEV_1$ 값은 Vmax spectra 22d 기의 측정값을 임상적으로 대체할 수 있음을 보여주었다.

치아 외과적 발거 전 혈액검사의 필요성과 이의 정책적 제시 (Needs of Preoperative Blood Sample Test in Surgical Extraction: Suggestion of New Policy)

  • 서미현;김성민;오진실;명훈;이종호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권5호
    • /
    • pp.332-336
    • /
    • 2012
  • Purpose: The third molar extraction is one of the mostly performed procedures in the department of oral and maxillofacial surgery. In most of dental clinic or hospital, the third molar extraction used to be frequently performed in an office-based surgery, and most patients did not have specific medical history with young ages. Medical history taking are dependent on the only way by asking to the patients about their individual conditions. Therefore, as the specialists of the oral and maxillofacial surgery in the field of dentistry, we suggest a new policy that the preoperative lab must be performed routinely before extraction of the third molar. Methods: This study is based on 1,096 patients who have been managed with third molar extractions, from March 2008 to September 2011 by a single surgeon. The preoperative lab, including complete blood count, coagulation panel, chemistry and serology, was performed before any surgical procedures. The results were informed to the patients regardless of their abnormalities, and any abnormalities related to the surgical procedures, such as platelet count and coagulation factors, were checked and corrected safely. Results: Through the preoperative blood test, systemic diseases that the patients had not recognized before, such as anemia, leukopenia, fatty liver and chronic renal disease, were identified. Patients with acute or chronic leukemia, Hepatitis B, and HIV positive, were also detected as a small number. Also, the possibilities of the cross-infection between dentists and patients or between patients and patients, and any other emergency situations can be prevented; as well as the public health condition can be improved, too. The patients were satisfied with low cost preventive blood test and high quality of medical services. Conclusion: Therefore, routine medical lab testing, including history taking are needed before an office-based minor surgery, such as third molar extractions, and these results were suggested as a new policy in the field of dentistry.