• 제목/요약/키워드: label-free immunosensor

검색결과 6건 처리시간 0.022초

Amperometric Immunosensor for Myeloperoxidase in Human Serum Based on a Multi-wall Carbon Nanotubes-Ionic Liquid-Cerium Dioxide Film-modified Electrode

  • Lu, Lingsong;Liu, Bei;Liu, Chenggui;Xie, Guoming
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3259-3264
    • /
    • 2010
  • A label-free amperometric immunosensor has been proposed for the detection of myeloperoxidase (MPO) in human serum. To fabricate such an immunosensor, a composite film consisting of N,N-dimethylformamide (DMF), multiwall carbon nanotubes (MWCNTs) and 1-ethyl-3-methyl imidazolium tetrafluoroborate ($EMIMBF_4$) suspension was initially formed on a glassy carbon electrode (GCE). Then cerium dioxide ($CeO_2$) dispersed by chitosan was coated on the GCE. After that, MPO antibodies (anti-MPO) were attached onto the nano$CeO_2$ surface. With a noncompetitive immunoassay format, the antibody-antigen complex formed between the immobilized anti-MPO and MPO in sample solution. The immunosensor was characterized by cyclic voltammetry, transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The factors influencing the performance of the immunosensor were studied in detail. Under optimal conditions, the current change before and after the immunoreaction was proportional to MPO concentration in the range of 5 to $300\;ng\;mL^{-1}$ with a detection limit of $0.2\;ng\;mL^{-1}$.

Immunosensor for Detection of Escherichia coli O157:H7 Using Imaging Ellipsometry

  • Bae Young-Min;Park Kwang-Won;Oh Byung-Keun;Choi Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권8호
    • /
    • pp.1169-1173
    • /
    • 2006
  • Imaging ellipsometry (IE) for detection of binding of Escherichia coli O157:H7 (E. coli O157:H7) to an immunosensor is reported. A protein G layer, chemically bound to a self-assembled layer of 11-mercaptoundecanoic acid (11-MUA), was adopted for immobilization of monoclonal antibody against E. coli O157:H7 (Mab). The immobilization of antibody was investigated using surface plasmon resonance. To fabricate antibody spots on a gold surface, protein G solution was spotted onto the gold surface modified with an 11-MUA layer, followed by immobilizing Mab on the protein G spot. Ellipsometric images of the protein G spot, the Mab spot, and Mab spots with binding of E. coli O157:H7 in various concentrations were acquired using the IE system. The change of mean optical intensity of the Mab spots in the ellipsometric images indicated that the lowest detection limit was $10^3$CFU/ml for E. coli O157:H7. Thus, IE can be applied to an immunosensor for detection of E. coli O157:H7 as a detection method with the advantages of allowing label-free detection, high sensitivity, and operational simplicity.

비표지 면역센서에 의한 냉장유통 식품 중 Pseudomonas aeruhinosa의 간이검출 (Detection of Pseudomonas aeruginosa with a Label-free Immunosensor from Various Cold Storage Foods)

  • 김남수;박인선;김동경
    • 한국식품위생안전성학회지
    • /
    • 제18권3호
    • /
    • pp.101-106
    • /
    • 2003
  • 냉장식품의 주요한 변패원일균으로서 저온세균인 Pseudomonas aeruhinosa를 최소 전처리한 후 신속히 검출할 수 있는 비표지 면역센서 시스템을 개발하였다. 수정결정전극상으로의 생물요소인 항체의 고정화는 이형이기능성 가교화제인 sulfosuccinimidyl 6-[3-(2-pyridyldithio)propionamido] hexanoate를 사용하여 항체를 티올화시킨 후 티올화된 항체를 화학흡착하여 행하였고, P. aeruginosa flagella에 대한 단클론항체를 사용하였을 때 다클론항체를 사용한 경우보다 센서감응이 우수한 것으로 나타났다. 항체가 고정화된 센서 chip과 flow형 quart crystal microbalance 계측 시스템을 이용하여 균 첨가 및 증균을 행한 10종의 모델시료에 대한 계측을 행하였다. 이 때, 시료자체에 의한 진동수변화가 52~89 Hz 범위인 반면 균 첨가 시에 나타난 진동수변화는 108~200 Hz이었고 증균시료에 의한 진동수변화는 162~222 Hz 범위로 나타났다. 시스템 안정화, 시료주입 및 정상상태이 센서반응 획득, 시스템 세척으로 이루어지는 한 주기의 센서계측에 소요된 시간은 모든 시료에 있어 30분 이내였다.

Protein G를 포함하는 수정미소저울 센서 칩과 정제되지 않은 항혈청을 이용한 헵토글로빈과 트랜스페린의 면역분석 (Immunoassay of haptoglobin and transferrin with proteinG-containing QCM sensor chip and unpurified antiserum)

  • 하인영;최석정
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.380-386
    • /
    • 2008
  • Quartz crystal microbalance immunosensor has a capacity to perform a label-free and real time detection of a trace amount of analyte through the specific interaction between antibody and antigen. However, immobilization of antibody molecules on the sensor surface is a troublesome procedure for researchers who are not experienced in chemistry. Protein G has a specific affinity to antibody and would serve as a capturing agent for antibody when immobilized on the sensor surface. In this work, we prepared a protein G sensor chip by immobilizing protein G on the surface of quartz crystal microbalance and examined its capability to detect human haptoglobin or human transferrin with unpurified corresponding antiserum. Specific and dose dependent response was observed when the protein G chip was used for detection of antigens after saturated with antiserum. We also verified several advantageous aspects of the protein G chip such as improved flexibility and sensitivity.

면역센서의 원리와 의학적 응용 (The Principles and Metrical Applications of Immunocsensors)

  • 김의락;백세환
    • KSBB Journal
    • /
    • 제17권2호
    • /
    • pp.121-136
    • /
    • 2002
  • Immunosensors are of great interest because of their potential utility as specific, simple, label-free, direct detection means and provision of reduction in size, cost and time of analysis comparing with conventional immunoassay. In the last two decades, many reports have been published on the use of immunosensors for a wide range of applications to clinical diagnostics, pharmaceutical chemistry, environmental monitoring, biotechnology and food industries. There are also numerous transduction techniques developed such as electrochemical techniques, piezoelectric crystal, and surface plasmon resonance receiving much attention for the direct monitoring of immune reactions at solid surfaces. In this article, the principles, characteristics, structures, fonctions and clinical applications of immunosensors were reviewed

Reduced graphene oxide field-effect transistor for biomolecule detection and study of sensing mechanism

  • Kim, D.J.;Sohn, I.Y.;Kim, D.I.;Yoon, O.J.;Yang, C.W.;Lee, N.E.;Park, J.S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.431-431
    • /
    • 2011
  • Graphene, two dimensional sheet of sp2-hybridized carbon, has attracted an enormous amount of interest due to excellent electrical, chemical and mechanical properties for the application of transparent conducting films, clean energy devices, field-effect transistors, optoelectronic devices and chemical sensors. Especially, graphene is promising candidate to detect the gas molecules and biomolecules due to the large specific surface area and signal-to-noise ratios. Despite of importance to the disease diagnosis, there are a few reports to demonstrate the graphene- and rGO-FET for biological sensors and the sensing mechanism are not fully understood. Here we describe scalable and facile fabrication of rGO-FET with the capability of label-free, ultrasensitive electrical detection of a cancer biomarker, prostate specific antigen/${\alpha}1$-antichymotrypsin (PSA-ACT) complex, in which the ultrathin rGO sensing channel was simply formed by a uniform self-assembly of two-dimensional rGO nanosheets on aminated pattern generated by inkjet printing. Sensing characteristics of rGO-FET immunosensor showed the highly precise, reliable, and linear shift in the Dirac point with the analyte concentration of PSA-ACT complex and extremely low detection limit as low as 1 fg/ml. We further analyzed the charge doping mechanism, which is the change in the charge carrier in the rGO channel varying by the concentration of biomolecules. Amenability of solution-based scalable fabrication and extremely high performance may enable rGO-FET device as a versatile multiplexed diagnostic biosensor for disease biomarkers.

  • PDF