• Title/Summary/Keyword: lR Curve

Search Result 329, Processing Time 0.034 seconds

Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Lithospermic Acid B in Rat Serum

  • Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Kim, Youn-Chul;Sohn, Dong-Hwan;Lee , Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.27 no.12
    • /
    • pp.1202-1206
    • /
    • 2004
  • A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/ MS) method for the determination of lithospermic acid B (LSB) in rat serum was developed. LSB and internal standard, 7-hydroxy-3-phenyl-chromen-4-one (HPC) were extracted from rat serum with methyl-tert-butyl ether at acidic pH and analyzed on a Luna $C_8$ column with the mobile phase of acetonitrile-ammonium formate (10 mM, pH 6.5) (50:50, v/v). The analytes were detected using a negative electrospray ionization tandem mass spectrometry in the multiple- reaction-monitoring mode. The standard curve was linear $(r^2 = 0.997)$ over the concentration range of 10.0-500 ng/mL. The coefficient of variation and relative error for intra- and interassay at three QC levels were 1.1~6.2% and -10.3~-2.7%, respectively. The recovery of LSB from serum sample ranged from 73.2 to 79.5%, with that of HPC (internal standard) being 75.1 %. The lower limit of quantification for LSB was 10 ng/mL using 50 ${\mu}L$ of serum sample.

Liquid Chromatography-tandem Mass Spectrometry for Quantification of Dioscin in Rat Plasma

  • Kong, Tae Yeon;Ji, Hye Young;Choi, Sang-Zin;Son, Miwon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.55-58
    • /
    • 2013
  • Dioscin is a biologically active steroidal saponin with anticancer and hepatoprotective effects. A rapid, selective, and sensitive liquid chromatographic method with electrospray ionization tandem mass spectrometry was developed for the quantification of dioscin in rat plasma. Dioscin was extracted from rat plasma using ethyl acetate at acidic pH. The analytes were separated on a Halo C18 column using gradient elution of acetonitrile and 0.1% formic acid and detected by tandem mass spectrometry in selected reaction monitoring mode. The standard curve was linear ($r^2$ = 0.998) over the concentration range of 1-100 ng/mL. The lower limit of quantification was 1.0 ng/mL using 50 ${\mu}L$ of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.3 to 8.0% and -5.4 to 10.0%, respectively. This method was applied successfully to the pharmacokinetic study of dioscin after oral administration of dioscin at a dose of 29.2 mg/kg in male Sprague-Dawley rats.

Simultaneous Determination and Monitoring of Bisphenols in River Water using Gas Chromatography-Mass Spectrometry (GC-MS 를 이용한 하천수 중 Bisphenol계 화합물의 동시분석 및 모니터링)

  • Kim, Jihyun;Choi, Jeong-Heui;Kang, Tae-Woo;Kang, Taegu;Hwang, Soon-Hong;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.154-160
    • /
    • 2017
  • BACKGROUND:This study was carried out to establish an efficient sample preparation for the simultaneous determination of bisphenols (BPs) in river water samples using gas chromatography-mass spectrometry (GC-MS). Sample preparation was examined with conventional extraction methods, such as solid-phase extraction (SPE) and liquid-liquid extraction (LLE), and their efficiency was compared with validation results, including linearity of calibration curve, method detection limit (MDL), limit of quantification (LOQ), accuracy, and precision. METHODS AND RESULTS:The BPs (bisphenol A, BPA; bisphenol B, BPB; bisphenol C, BPC; bisphenol E, BPE; bisphenol F, BPF; bisphenol S, BPS) were analyzed using GC-MS. The range of MDLs by SPE and LLE methods was $0.0005{\sim}0.0234{\mu}g/L$ and $0.0037{\sim}0.2034{\mu}g/L$, and that of LOQs was $0.0015{\sim}0.0744{\mu}g/L$ and $0.0117{\sim}0.6477{\mu}g/L$, respectively. The calibration curve obtained from standard solution of $0.004{\sim}4.0{\mu}g/L$ (SPE) and $0.016{\sim}16{\mu}g/L$ (LLE) showed good linearity with $r^2$ value of 0.9969 over. Accuracy was 93.2~108% and 97.4~120%, and precision was 1.7~4.6% and 0.7~6.5%, respectively. The values of MDL and LOQ resulted from the SPE method were higher than those from the LLE method, particularly those values of BPA were highest among the BPs. Based on the results, the SPE method was applied to determine the BPs in river water samples. Water samples were collected from mainstream, tributary and sewage wastewater treatment plants (SWTPs) in the Yeongsan river basin. The concentration of BPB, BPC, BPE, BPF and BPS were not detected in all sites, whereas BPA was ranged $0.0095{\sim}0.2583{\mu}g/L$, which was $0.0166{\sim}0.0810{\mu}g/L$ for mainstreams, $0.0095{\sim}0.2583{\mu}g/L$ for tributaries, $0.0352{\sim}0.1217{\mu}g/L$ for SWTPs. CONCLUSION: From these results, the SPE method was very effective for the simultaneous determination of BPs in river water samples using GC-MS. We provided that it is a convenient, reliable and sensitive method enough to monitor and understand the fate of the BPs in aquatic ecosystems.

Validation of ICP-MS method for trace level analysis of Pb in plasma (혈장 중 극미량 납 분석을 위한 ICP-MS 분석법 검증)

  • Lee, Sung-Bae;Kim, Yong-Soon;Lee, Yong-Hoon;Ahn, Byung-Joon;Kim, Nam-Soo;Lee, Byung-Kook;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.309-316
    • /
    • 2015
  • The analytical method of lead in plasma by ICP-MS was validated after securing environment within class 1,000 classification. We tested specificity and accuracy of within-run and between-run. According to measurement of the amount of suspended particulates in a clean room, 0.3~62 particles were detected in 0.3 µm size while 0.0~28.3 particles were observed in 0.5 µm size. Total suspended particulates met required environment with up to 90.3 particles. The MDL (Method detection limit) of the sample which has been fabricated using fetal bovine serum (FBS) blank was 1.77 ng/L, and LOQ (Limit of quantification) was 5.55 ng/L. The slope, intercept and correlation coefficient of the calibration curve were y=1.09×10−3x+4.88×10−2 and r=0.9999, which showed good correlation. The specificity, within-run and between-run accuracy satisfied the standard at more than 50 ng/L. The average lead concentration in plasma of the general people, current workers and retired workers was 55.4 ng/L, 440 ng/L, and 132 ng/L.

Migration Measurement of Volatile Organic Compounds (VOCs) from Polystyrene-made Food Containers into Distilled Water (폴리스티렌 식품용기로부터 증류수로 용출되는 휘발성유기화합물의 분석)

  • Kim, Nam-Hoon;Kim, Ae-Kyeong;Cho, Tae-Hee;Park, Kyung-Ai;Kwak, Jae-Eun;Kim, Ji-Young;Kim, Il-Young;Chae, Young-Joo;Kim, Min-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.203-208
    • /
    • 2010
  • In this study, the level of migration of 5 kinds of volatile organic compounds (VOCs) (toluene, styrene, ethylbenzene, isopropylbenzene and n-propylbenzene) into distilled water from polystyrene-made food containers was measured using Purge&Trap combined with GC/FID. The contents of the VOCs which have regulatory limits in Korea food code only for material specification were determined under three exposure conditions which were 30 min at $60^{\circ}C$, 30 min at $95^{\circ}C$ and actual situation of instant noodle intake. The calibration curve of 5 compounds showed good linearity ($^r2$ = 0.9976~0.9995) within the concentration range of 1~50 ng/mL. The limit of detection (LOD) and limit of quantification (LOQ) were validated at range of 0.041~0.092 and 0.135~0.304 ng/mL, respectively. The average migration contents of 5 compounds were below 5 ng/mL except for styrene. The average contents of styrene were highly detected at $95^{\circ}C$ for 30 min exposure (52.71 ng/mL). Under actual condition at instant noodle intake, the average contents of styrene was 17.23 ng/mL. The results demonstrated that the migration rate of VOCs was related to storage temperature and time.

Simultaneous Determination of Isoegomaketone and Perillaketone in Perilla frutescens (L.) Britton Leaves by HPLC-DAD (HPLC-DAD를 이용한 차조기 잎의 Isoegomaketone 및 Perillaketone의 동시분석법 확립)

  • Nam, Bo Mi;Lee, Seung Young;Kim, Jin-Baek;Kang, Si-Yong;Jin, Chang Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.1
    • /
    • pp.79-83
    • /
    • 2016
  • This study developed an HPLC analysis method for the determination of isoegomaketone (IK) and perillaketone (PK) in Perilla frutescens (L.) Britton leaves. P. frutescens ethanol extract was optimized through an HPLC analysis using a C18 column ($250{\times}4.6mml$, D, $S-5{\mu}m$, 12 nm) with gradient elution of water and acetonitrile as the mobile phase at a flow rate of 1 mL/min and a UV detection wavelength of 254 nm. The results of this method showed linearity in the calibration curve at a coefficient of correlation ($R^2$) of IK 0.9995, PK 0.9998. The limits of detection (LOD) for IK and PK were $0.234{\mu}g/mL$ and $0.952{\mu}g/mL$. The limits of quantification (LOQ) for IK and PK were $0.017{\mu}g/mL$ and $0.043{\mu}g/mL$. The inter-day precision RSDs of IK and PK in the P. frutescens were 1.25 to 2.69% and 0.36 to 1.10%, respectively, and the intra-day precision RSDs of IK and PK were 0.96 to 2.51% and 0.90 to 1.93%, respectively. The accuracies of IK and PK were 96.31 to 97.92% and 101.26 to 105.14%. In conclusion, this method was applied successfully to the detection of IK and PK in P. frutescens.

Analysis and Distribution of Esculetin in Plasma and Tissues of Rats after Oral Administration

  • Kim, Ji-Sun;Ha, Tae-Youl;Ahn, Jiyun;Kim, Suna
    • Preventive Nutrition and Food Science
    • /
    • v.19 no.4
    • /
    • pp.321-326
    • /
    • 2014
  • In this study, we developed a method to quantify esculetin (6,7-dihydroxycoumarin) in plasma and tissues using HPLC coupled with ultraviolet detection and measured the level of esculetin in rat plasma after oral administration. The calibration curve for esculetin was linear in the range of 4.8 ng/mL to 476.2 ng/mL, with a correlation coefficient ($r^2$) of 0.996, a limit of detection value of 33.2 ng/mL, and a limit of quantification value of 100.6 ng/mL. Recovery rates for the 95.2 ng/mL and 190.5 ng/mL samples were 95.2% and 100.3%, within-runs and 104.8% and 101.0% between-runs, respectively. The relative standard deviation was less than 7% for both runs. In the pharmacokinetic analysis, the peak plasma esculetin level was reached 5 min after administration ($C_{max}=173.3ng/mL$; $T_{1/2}=45min$; $AUC_{0{\sim}180min}=5,167.5ng{\cdot}min/mL$). At 180 min post-administration (i.e., after euthanasia), esculetin was only detectable in the liver ($30.87{\pm}11.33ng/g$) and the kidney ($20.29{\pm}7.02ng/g$).

Diffusion Tensor-Derived Properties of Benign Oligemia, True "at Risk" Penumbra, and Infarct Core during the First Three Hours of Stroke Onset: A Rat Model

  • Chiu, Fang-Ying;Kuo, Duen-Pang;Chen, Yung-Chieh;Kao, Yu-Chieh;Chung, Hsiao-Wen;Chen, Cheng-Yu
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1161-1171
    • /
    • 2018
  • Objective: The aim of this study was to investigate diffusion tensor (DT) imaging-derived properties of benign oligemia, true "at risk" penumbra (TP), and the infarct core (IC) during the first 3 hours of stroke onset. Materials and Methods: The study was approved by the local animal care and use committee. DT imaging data were obtained from 14 rats after permanent middle cerebral artery occlusion (pMCAO) using a 7T magnetic resonance scanner (Bruker) in room air. Relative cerebral blood flow and apparent diffusion coefficient (ADC) maps were generated to define oligemia, TP, IC, and normal tissue (NT) every 30 minutes up to 3 hours. Relative fractional anisotropy (rFA), pure anisotropy (rq), diffusion magnitude (rL), ADC (rADC), axial diffusivity (rAD), and radial diffusivity (rRD) values were derived by comparison with the contralateral normal brain. Results: The mean volume of oligemia was $24.7{\pm}14.1mm^3$, that of TP was $81.3{\pm}62.6mm^3$, and that of IC was $123.0{\pm}85.2mm^3$ at 30 minutes after pMCAO. rFA showed an initial paradoxical 10% increase in IC and TP, and declined afterward. The rq, rL, rADC, rAD, and rRD showed an initial discrepant decrease in IC (from -24% to -36%) as compared with TP (from -7% to -13%). Significant differences (p < 0.05) in metrics, except rFA, were found between tissue subtypes in the first 2.5 hours. The rq demonstrated the best overall performance in discriminating TP from IC (accuracy = 92.6%, area under curve = 0.93) and the optimal cutoff value was -33.90%. The metric values for oligemia and NT remained similar at all time points. Conclusion: Benign oligemia is small and remains microstructurally normal under pMCAO. TP and IC show a distinct evolution of DT-derived properties within the first 3 hours of stroke onset, and are thus potentially useful in predicting the fate of ischemic brain.

A study on the separation and determination of the rare earth Elements by the AG® 50W-X8 cation exchange resin (AG® 50W-X8 양이온교환수지를 이용한 희토류원소의 분리와 분석에 관한 연구)

  • Lee, Jung Sook;Choi, Beom Suk
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.272-278
    • /
    • 2008
  • Methods to separate 14 rare earth elements (REEs) and yttrium by the $AG^{(R)}$ 50W-X8 cation exchange resin, and to determine REEs by inductively coupled plasma atomic emission spectrophotometry (ICP-AES) were described. Ion exchange capacities of REEs on the resin were so high that the REEs were quantitatively ion exchanged under the flow rate of 0.3~1.0 mL/min at pH 1~6. The breakthrough capacity curve of the REEs showed that ion exchange capacities of light REEs (Cerium group) were greater than that of the heavy REEs (Yttrium group). When $200{\mu}g$ of each REEs was ion exchanged on 100 mg of resin, most of the heavy REEs were quantitatively desorbed with 10 mL of 2.0 M of $HNO_3$, while most of the light REEs with 30 mL. The method was applied to the monazite sample. The REEs could be separated from matrix, since ion exchange capacities of matrix ions of Ca, Ti, Mg, Mn were much lower than that of the REEs. However the relative standard deviations of the analytical results by the present method were not improved, as high as 1~5%.

Pharmacokinetic and Pharmacodynamic Characterization of Gliclazide in Healthy Volunteers

  • Kim, Ho-Soon;Yun, Min-Hyuk;Kwon, Kwang-Il
    • Archives of Pharmacal Research
    • /
    • v.26 no.7
    • /
    • pp.564-568
    • /
    • 2003
  • Pharmacokinetic and pharmacodynamic properties of gliclazide were studied after an oral administration of gliclazide tablets in healthy volunteers. After an overnight fasting, gliclazide tablet was orally administered to 11 volunteers; Additional 10 volunteers were used as a control group (i.e., no gliclazide administration). Blood samples were collected, and the concentration determined for gliclazide and glucose up to 24 after the administration. Standard pharmacokinetic analysis was carried out for gliclazide. Pharmacodynamic activity of the drug was expressed by increase of glucose concentration ($\Delta$PG), by area under the increase of glucose concentration-time curve ($AUC_{$\Delta$PG}$) or by the difference in increase of glucose concentration ($D_{$\Delta$PG}$) at each time between groups with and without gliclazide administration. Pharmacokinetic analysis revealed that $C_{max}, T_{max}$, CL/F (apparent clearance), V/F (apparent volume of distribution) and half-life of gliclazide were $4.69\pm1.38 mg/L, 3.45\pm1.11 h, 1.26\pm0.35 L/h, 17.78\pm5.27 L, and 9.99\pm2.15 h$, respectively. When compared with the no drug administration group, gliclazide decreased significantly the $AUC_{$\Delta$PG}$ s at 1, 1.5, 2, 2.5, 3 and 4 h (p<0.05). The $\Delta$PGs were positively correlated with $AUC_{gliclazide}$ at 1 and 1.5 h (p<0.05), and the correlation coefficient was maximum at 1 h (r = 0.642) and gradually decreased at 4 h after the administration. The $AUC_{$\Delta$PG}$s were positively correlated with $AUC_{gliclazide}$ at 1, 2, 3 and 4 h (p<0.05), and the maximum correlation coefficient was obtained at 2 h (r=0.642) after the administration. The $D_{$\Delta$PG}$ reached the maximum at 1 h, remained constant from 1 h to 3 h, and decreased afterwards. Therefore, these observations indicated that maximum hypoglycemic effect of gliclazide was reached at approximately at 1.5 h after the administration and the effect decreased, probably because of the homeostasis mechanism, in health volunteers.