• Title/Summary/Keyword: lR Curve

Search Result 326, Processing Time 0.029 seconds

A Fast Determination of Globotriaosylsphingosine in Plasma for Screening Fabry Disease Using UPLC-ESI-MS/MS

  • Yoon, Hye-Ran
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.116-119
    • /
    • 2015
  • Globotriaosylsphingosine (lyso-Gb3) is considered as one of the biological marker for Fabry disease. To date, a reliable biomarker that reflects disease severity and progression has not been discovered to guide the management of Fabry disease. A new method included a simple protein precipitation with acetonitrile in 100 μL of plasma following analyte separation on an Phenomenex Kintex- C18 column using a gradient elution (0.1% formic acid in 5-90% acetonitrile). Total run time was within 12 min including sample preparation and MS/MS analysis. The limit of detection and limit of quantitation were 1 ng/mL and 2 ng/mL, respectively. The calibration curve was linear over the concentration range of 2.0-200.0 ng/mL (r2 = 0.9999). Inter-day accuracy and precision at 7 level were 93.4-100.7% with RSD of 0.55-5.97%. Absolute recovery was 97.6-98.6%. The method was applied to human and mice plasma, proved the suitability for quantification of lyso-Gb3 for screening, diagnosis and therapeutic monitoring of Fabry disease patients.

Aquatic Plants for Wastewater Treatment (수생식물을 이용한 수질정화에 관한 연구)

  • 나규환;권성환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.49-55
    • /
    • 1996
  • Water parsley(Oenanthe javanica(Blume) DC) was raised with varying population density(S) in the laboratory aquarium unit to determine the growth equation. The population density was measure after 7 days. The resultant growth curve was well fit to the equation 1/S = A+B (1/S0) with a high correlation coefficient ($R^2$ = 0.999). The maximum specific absorption rate was $9.011 \times 10^{-5}$ kg $NO_x-N/kg$ water parsley$\cdot$day and $1.31 \times 10^{-5}$ kg $PO_4-P/kg$ water parsley$\cdot$day when the average population density was $2.62 kg/m^2$. The relationship between population density and nutrient absorption rate, the absorption rate of $NO_x-N$ was 5.04~5.24 mg/l$\cdot$day when the population density was $7.51~10.0 $mg/m^2\cdot day$ and the absorption rate of $PO_4-P$ was 0.56~0.78 mg/l$\cdot$day when the population density was 5.02~10.0 $kg/m^2\cdot day$. Taking into account the nutrient absorption rate and growth rate, the population density between $7.0 kg/m^2\cdot day$ and $8.0 kg/m^2 \cdot day$ was selected. The removal rate of nutrient was investigated after 7 days culture. Removal rate of $NO_x-N$ was 95.6~99.95% with initial concentration of 35 mg $NO_x-N/l$, and the removal rate of $PO_4-P$ was also high, indicating 80.24~98.9% with initial concentration of 5.95 mg $PO_x-P/l$.

  • PDF

A new merging-zone flow injection system for the quantification of ferrous and ferric ions in aqueous solution and sludge of wastewater

  • Farhood, Ahmed Saleh;Taha, Dakhil Nassir
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.218-227
    • /
    • 2022
  • A simple and fast throughput flow injection (FI) system with a merging-zone technique was designed to determine ferrous and ferric in an aqueous solution. The method is based on the direct reaction of ferrous with a Bathophenanthroline reagent (Bphen) in acidic media. The forming red complex absorbs light at 533 nm. All conditions of the flow injection system were investigated. The analytical curve of ferrous was linear in the range of 0.07 to 4 mg/L with an r2 value of 0.9968. The detection and quantification limits were 0.02 and 0.04 mg/L, respectively. The molar absorptivity and Sandell's sensitivity were 4.0577 × 106 L/mol cm and 25 × 10-5 ㎍/cm2, respectively. The homemade valve was low-cost with high repeatability (n = 7) at an RSD of 1.26 % and zero dead volume. The values of the dispersion coefficient were 2.318, 2.022, and 1.636 for the concentrations of 0.2, 1, and 3 mg/L, respectively. The analysis throughput of the designed flow injection unit was 57 sample per hour.

Functional Role of $^{60}RR^{61}$ in 23S rRNA Methylation, Which is in N-Terminal End Region of ErmSF (ErmSF의 N-Terminal End Region에 존재하는 $^{60}RR^{61}$의 23S rRNA Methylation에서의 역할)

  • Jin, Hyung-Jong
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.193-198
    • /
    • 2008
  • ErmSF is one of the proteins which are produced by Streptomyces fradiae to avoid suicide by its autogenous macrolide antibiotic, tylosin and one of ERM proteins which are responsible for transferring the methyl group to $A_{2058}$ (Escherichia coli coordinate) in 23S rRNA, which reduces the affinity of MLS (macrolide-lincosamide-streptogramin B) antibiotics to 23S rRNA, thereby confers the antibiotic resistance on microorganisms ranging from antibiotic producers to pathogens. ErmSF contains an extra N-terminal end region (NTER), which is unique to ErmSF and 25% of amino acids of which is arginine known well to interact with RNA. Noticeably, arginine is concentrated in $^{58}RARR^{61}$ and functional role of each arginine in this motif was investigated through deletion and site-directed mutagenesis and the activity of mutant proteins in cell R60 and R61 was found to play an important role in enzyme activity through the study with deletion mutant up to R60 and R61. With the site-directed mutagenesis using deletion mutant of 1 to 59 (R60A, R61A, and RR60, 61AA), R60 was found more important than R61 but R61 was necessary for the proper activity of R60 and vice versa. And these amino acids were presumed to assume a secondary structure of $\alpha$-helix.

Some Statistical Considerations for the Estimation of Urinary Mercury Excretion in Normal Individuals (정상인의 요중 수은배설량 추정의 통계학적 연구)

  • Park, Hee-Sook;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 1980
  • Purpose of this study is to find out proper means of estimating the urinary mercury excretion in the normal individuals. Whole void volume was collected every 2 hours beginning from 6 o'clock in the morning until 6 o'clock next morning. Mercury excretion in each urine specimen was measured by NIOSH recommended dithizone colorimetric method (Method No.: P & CAM 145). Urinary concentration of mercury was adjusted by two means: specific gravity of 1.024 and a gram of creatinine excretion per liter of urine comparing the data with the unadjusted ones. Mercury excretion in 24-hour urine specimen was calculated by adding the amounts measured with the hourly collected specimens of each individual. Statistical analysis of the urinary mercury excretion revealed the following results: 1. Frequency distribution curve of mercury excreted in urine of hourly specimens was best fitted to power function expressed in the form of $y=ax^b$. Adjustment of the urinary mercury concentration by creatinine excretion was shown to be superior($y=1674x^{-1.52},\;r^2=0.95$) over nonadjustment($y=2702x^{-1.57},\;r^2=0.92$) and adjustment by specific gravity of 1.024($y=4535x^{-1.66},\;r^2=0.93$). 2. Both log-transformed mercury excretion in hourly voided specimens and mercury excretion itself in 24 hour specimens showed the normal distributions. 3. The frequency distribution of mercury adjusting the urinary concentration of mercury by creatinine excretion was best fitted to a theoretical normal distribution with the sample means and standard deviation than those unadjusted or adjusted with specific gravity of 1.024. 4. Average urinary mercury excretions in 24-hour urine specimen in an individual were as follows: a) Unadjusted mercury excretion mean and standard deviation : $$18.6{\pm}13.68{\mu}gHg/l$$. median : $$16.0\;{\mu}gHg/l$$. range : $$0.0-55.10\;{\mu}gHg/l$$. b) Adjusted with specific gravity mean : $$20.7{\pm}11.76\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ median : $$20.7\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ range : $$0.0-52.9\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ c) Adjusted with creatinine excretion mean and standard deviation : $$10.5{\pm}6.98\;{\mu}gHg/g$$ creatinine/l median : $$9.4\;{\mu}gHg/g$$ creatinine/l range : $$0.0-26.7\;{\mu}gHg/g$$ creatinine/l 5. No statistically significant differences were found between means calculated from 24-hour urine specimens and those from hourly specimens transformed into logarithmic values. (P<0.05).

  • PDF

Evaluation of Mechanical Properties and Fatigue Behavior of STS 304L due to Plastic Working (소성가공에 따른 STS 304L 재료의 기계적 특성 및 피로평가)

  • Shim, Hyun-Bo;Kim, Young-Kyun;Suh, Chang-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.635-643
    • /
    • 2017
  • The purpose of this study is to investigate the influence of the cold reduction rate and an ultrasonic fatigue test (UFT) on the fatigue behaviors of STS 304L. The tensile strength, yield strength, hardness value and fatigue limit in the UFT fatigue test linearly increased as thickness decreased from 1.5 mm to 1.1 mm, as the cold reduction rate of STS 304L increased. As a result of the UFT fatigue test (R = -1) of four specimens, the fatigue limit of the S-N curve formed a knee point in the region of $10^6$, and the 2nd fatigue limit caused by giga cycle fatigue did not appeared. In the case of t = 1.1 mm, the highest fatigue limit was 345 MPa, which was 64.3% higher than the original material (t = 1.5 mm). As a result of the UFT fatigue test of STS 304L, many small surface cracks occurred, grown, coalesced while tearing.

Study on the Variation of Energy Dissipation Factor of Reinforced Concrete Beam under Cyclic Loading (반복하중을 받는 철근콘크리트 보의 에너지소산계수 변화 특성 고찰)

  • Suk-Hyeong Yoo;Dae-Young Kang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.86-93
    • /
    • 2023
  • As the hysteretic behavior of reinforced concrete members under cyclic loading progresses, the energy dissipation ability decreases due to a decrease in stiffness and strength and pinching effects. However, the guideline "Nonlinear Analysis Model for Performance-Based Seismic Design of Reinforced Concrete Building Structures, 2021" requires calculating a single energy dissipation factor for each member and all histeric step, so the decrease in energy dissipation capacity according to histeric step cannot be considered. It is judged that Therefore, in this study, the energy dissipation factor according to the histeric step was examined by comparing the existing experimental results and the nonlinear time history analysis results for a general beam under cyclic loading. The energy dissipation factor was calculated as the ratio of the energy dissipation amount of the actual specimen to the energy dissipation amount of the idealized elastoplastic behavior obtained as a result of nonlinear time history analysis. In the existing experiment results, the energy dissipation factor was derived by calculating one cycle for each histeric step, and the energy dissipation factor was derived based on the nonlinear modeling process in the guidelines. In the existing experimental study, the energy dissipation factor was calculated by setting each histeric step (Y-L-R), and the energy dissipation factor was found to be 0.36 in the Y-L step and 0.28 in the L-R step, and the energy dissipation factor in the guideline was found to be 0.31. This shows that the energy dissipation factor calculation formula in the guidelines does not indicate a decrease in the energy dissipation capacity of reinforced concrete members.

Development of Nozzleless Booster casted to Solid Propellant with Al as a Metal Fuel (알루미늄(Al) 금속연료 조성의 추진제를 이용한 무노즐 부스터 개발)

  • Khil, Taeock;Jung, Eunhee;Lee, Kiyeon;Ryu, Taeha;Lee, Hyoungjin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.52-62
    • /
    • 2017
  • The study for the performance characteristics of the nozzleless booster used in ramjet booster was carried out. Performances related to pressure and thrust for nozzleless booster are lower than classical motor those because of absence of convergent and divergent sections of nozzle. To solve this problem, it developed a high-performance propellant with maximum impulse density included Al as metal fuel. Using the nozzleless booster casted the propellant, ground test of it was carried out by varying the length-to-diameter ratio (L/D ratio) of the propellant. Specific impulse of nozzleless booster was limited to about 75 percents of its value compared with that of classical motor adapted nozzle in the same propellant and propellant length and will be estimated approximately 85 percents of its value compared with that of classical motor at same average pressure in terms of the curve fitting by our test results.

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

Toxicokinetics of paraquat in Korean patients with acute poisoning

  • Kim, Hak-Jae;Kim, Hyung-Ki;Lee, Hwayoung;Bae, Jun-Seok;Kown, Jun-Tack;Gil, Hyo-Wook;Hong, Sae-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.1
    • /
    • pp.35-39
    • /
    • 2016
  • To conduct a kinetic study of paraquat (PQ), we investigated 9 patients with acute PQ intoxication. All of them ingested more than 20 ml of undiluted PQ herbicide to commit suicide and arrived at our hospital early, not later than 7 h after PQ ingestion. The urine dithionite test for PQ in all of the nine patients was strongly positive at emergency room. Blood samples were obtained every 30 min for the first 2~3 h and then every 1 or 2 h, as long as the clinical progression was stable among the patients for 30 h after PQ ingestion. The area under the plasma concentration-time curve ($AUC_{inf}$), which was extrapolated to infinity, was calculated using the trapezoidal rule. Toxicokinetic parameters, such as the terminal elimination half-life, apparent oral clearance, and apparent volume of distribution ($V_d/F$) were calculated. The maximum PQ concentration ($C_{max}$) and the time to reach maximum PQ concentration ($T_{max}$) were also obtained. Plasma PQ concentrations in nine patients were well described by a bi-exponential curve with a mean terminal elimination half-life of $13.1{\pm}6.8h$. $C_{max}$ and $AUC_{inf}$ were $20.8{\pm}25.7mg/l$ and $172.5{\pm}160.3h{\cdot}mg/l$, respectively. Apparent volume of distribution and apparent oral clearance were $50.9{\pm}61.3l/kg$ and $173.4{\pm}111.2l/h$, respectively. There were a significant correlation (r=0.84; p<0.05) between the PQ amount ingested and $C_{max}$. $AUC_{inf}$ also showed a significant correlation (r=0.83; p<0.05) with the PQ amount ingested. These correlations provide evidence that PQ has dose-linear toxicokinetic characteristics.