• Title/Summary/Keyword: keeping temperature

Search Result 368, Processing Time 0.024 seconds

The cases report of postpartum hyperhidrosis caused by keeping overwarm (산욕기 과보온으로 야기된 산욕기 발한 과다에 대한 증례 보고)

  • Cho, Hyung-Lae
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.18 no.4
    • /
    • pp.203-210
    • /
    • 2005
  • Purpose : The keeping warm and avoidance of cold are one of important Korean traditional postpartum care, but sometimes overwarm for example over-bundling, an overheated room or a steam bath cause heavy sweats. I observed and treated three patients complained of heavy sweats, chills, fatigue, malaise, cold sensation and pain caused by keeping overwarm for postpartum care. Although the symptoms have aggravated, they have maintained keeping overwarm because of a belief of Korean traditional postpartum care. The purpose of these cases studies are to report postpartum hyperhidrosis caused by keeping overwarm and to make a point of keeping the appropriate room temperature and humidity during puerperium. Methods : I observed and treated three patients complained of heavy sweats, chills, fatigue, malaise, cold sensation and pain caused by keeping overwarm for postpartum care. I found that a cause of the symptoms was hyperhidrosis by keeping overwarm, and administered herbal medicine and was to keep the appropriate room temperature. Results : After medication of Herbal medicine(補中益氣湯加味方) and keeping the appropriate room temperature, they were improved. Conclusion : Postpartum care is not to keep overwarm but to keep the appropriate room temperature and humidity.

  • PDF

A Changes in Surface Temperature of Woodceramics Made from Pinus densiflora S. et. Z. - Effect of Heating Rate and Keeping Time at Maximum Temperature - (소나무로 제조된 우드세라믹의 표면온도변화 - 승온속도 및 최고온도에서 유지시간의 영향 -)

  • Oh, Seung Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.22-28
    • /
    • 2007
  • Using woodceramics made from sawdust board of pine thinning logs, changes in surface temperature were investigated, by the heating rate and keeping time at maximum temperature. The heating rate of $2^{\circ}C/min$ and keeping time at maximum temperature 1 hour, were the highest in surface temperature. Also, it was found that woodcermics maintained heat for a long time because the descending velocity of their surface temperature was slower than that of the heater.

Effect of Heating Rate and Keeping Time at Maximum Temperature on the Properties of Woodceramics Made from Thinned Logs (승온속도 및 최고온도 유지시간이 간벌재로 제조된 우드세라믹의 성질에 미치는 영향)

  • Oh, Seung-Won;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.3 s.131
    • /
    • pp.38-44
    • /
    • 2005
  • This research investigated the variation of density, the weight loss, dimensional shrinkage and heat conduction by the heating rate and keeping time at maximum temperature of woodceramics, when sawdust boards made from thinned logs of Pinus densiflora, Larix kaemferi and Pinus koraiensis were impregnated with phenol-formaldehyde resin, and then were formed by heating rate ($2^{\circ}C/min{\sim}6^{\circ}C/min$) and keeping time at maximum temperature (1~5 h). As the heating rate increased, the density and thickness shrinkage decreased, but weight loss and linear shrinkage increased. The more the keeping time at maximum temperature, the greater the linear shrinkage and thickness shrinkage. The heating conduction was superior at the heating rate is $2^{\circ}C/min$ and the keeping time at maximum temperature of 2 hs.

A Study on the Heat and Moisture Transport Properties of Vapor-Permeable Waterproof Finished Fabrics for Sports Wear (스포츠웨어용 투습방수직물의 열·수분이동 특성에 관한 연구)

  • Son, Bu Hun;Kim, Jin-A;Kwon, Oh Kyung
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.220-226
    • /
    • 2000
  • This study was to determine the characteristics of vapor-permeable waterproof finished fabric by the coating method. 4 different kinds of coating fabrics (A : wet, porous, polyurethane, B : dry, no porous, polyurethane, C : shape memory polyurethane and D : dry, porous polyurethane) were used, which were developed recently With this sample, moisture transport rate ($40^{\circ}C$, 45%RH & $40^{\circ}C$, 95%RH), changes of coating side's shape by washing times, water repellency rate, contracted length, qmax, heat conductivity, heat keeping rate, heat keeping rate with cotton, heat keeping rate on humidity temperature and humidity within clothing etc. were checked. And it was done in a climate chamber under $20{\pm}2^{\circ}C$, $65{\pm}5%RH$. The results of this study were as follow; In the moisture vapor transmission of sample B and C increased on high temperature and high humidity while sample A and D decreased, on this condition. Qmax rate had high relation with ground fabric's surface properties and the order was A>C>D>B. Heat conductivity had high relation with thickness and surface properties. Heat keeping rates on sweat condition showed around half percents of heat keeping rates on normal condition, but had no relation with moisture vapor transport rate. Changes of the fabric's properties by washing times were different in accordance with the construction of fabrics and the coating resin. Sample C had tow heat keeping rate on the high temperature and humidity and high heat keeping rate on the low temperature and humidity Moisture transport rate of vapor-permeable waterproof finished fabrics had high relation with the properties of ground fabrics on low humidity condition, but on the high humidity condition, it was highly related with the properties of coating resin.

  • PDF

Effect of Storage Temperature and Keeping Materials on Storability and Quality of Chinese Yam (貯藏溫度와 充塡材料가 마의 貯藏과 品質에 미치는 影響)

  • 김영광
    • Korean Journal of Plant Resources
    • /
    • v.10 no.1
    • /
    • pp.58-63
    • /
    • 1997
  • The experiment was done to clarify the effect of keeping material and storage temperature on weight and quality of Chinese yam (Dioscorea opposita) tuber. After the yam tubers were placed into the plastic boxes filled with different keeping materials [polyethylene (PE) film, hull, soil, sand, vermiculite], they were stored under different storage temperature(room, cold) from Oct. 15 to Mar. 15 when all the characters related to the tubers were measured. Soil or PE film as keeping materials was the lowest sound tuber rate when stored at room or cold temperature, respectively, while vermiculite was the highest in both storage temperature. When PE film and vermiculite in both storage temperatures were used as keeping materials, tuber weight were less reduced than the others. Brightness of chromaticity and moisture content were lower in room temperature storage than in cold temperature storage although the characteristics related to marketability were not affected by storage temperature. PE film had greater brightness and value 'a' of chromaticity but lower its 'b' value in the latter temperature than in the former temperature. Vermiculite, however, did the reverse result in comparison with PE film.

  • PDF

A Numerical Study on the Flow and Heat Transfer Characteristics in a Kimchi Refrigerator (김치냉장고 내의 유동 및 열전달 특성에 관한 수치해석)

  • 윤준원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1078-1087
    • /
    • 2003
  • Kimchi refrigerator is a household electric appliance developed with the wholly domestic technology for maturing and keeping kimchi. However, the principle of keeping is not yet revealed obviously. This numerical study has been conducted to investigate the flow and heat transfer characteristics in a kimchi refrigerator. The effects of arrangement variation of a evaporation tube are examined. Also, the heat transfer characteristics through the insulation material are discussed in detail. The flow and temperature field was simulated using the commercial code of CFX-5.3. A natural convection flow is formed through about 5/6 region from the bottom within the keeping space and accordingly, the 90% region of kimchi containers satisfies the temperature requirement with 0$\pm$0.5$^{\circ}C$. The stagnant flow exists in the upper 1/6 region of the keeping space and accordingly, the stratified high temperature distributions appear in the upper region of kimchi containers. The upward shift of the start location of a evaporation tube improves the temperature concentration toward $0^{\circ}C$ but the pitch variation is of no effect. The heat fluxes on the insulation surfaces show two-dimensional distributions with being higher toward the center. Through the variation of insulation thickness, 3.5% saving of insulation material is obtained under the same heat transfer rate.

A Study on the Optimum Design Parameters of the Thermostat for Coolant Temperature Control of an Automotive Engine (자동차용 기관의 냉각수 온도조절을 위한 서머스탯의 최적설계 변수설정에 관한 연구)

  • 박경석;신진식;원종필
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.1-16
    • /
    • 1993
  • It is widely recognized that exhaust emissions, fuel economy and engine torque are affected by engine temperature, and logic would suggest that a cooling system offering a better compromise of engine temperature would improve both overall engine performance and economy. Author measured coolant temperature of some parts and flow rate which are necessary to heat transfer in a engine. And Author determined parameters necessary for the optimum design of a thermostat to keep the best engine performance ; determined the optimum operating temperature of electric cooling fan. A summary of this study is followed. 1. Study of the effects of cooling condition to combustion character in a engine. 2. Analyze of heat transfer surrounding engine cylinders. 3. Study of the effects of cooling character to engine heat rejection, determination of the optimum collant temperature for keeping the optimum engine performance and determination of the optimum design of a thermostat for keeping that temperature.

  • PDF

Research on warmth-keeping, anti-bacteria and deodorant treatment for feet, the active organ of human body (행동기관으로서 발의 보온 및 항균방취에 대한 연구)

  • 한상덕;이상도;정중희
    • Journal of the Ergonomics Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.41-44
    • /
    • 1987
  • Researches were made on foot-warming, anti-bacteria and deodorant treatment. Feet, the very important organ to human body, perspire much and their temperature is lower than those of other parts. Hence, keeping feet warm, sanitary and deodorant is the area of this study. Latex sponge of activated carbon, impregnated open cell foam, treated with Vikol DZ-anti-bacteria finishing agent, was developed and tested for warmth-keeping by KSK 0560 test method and for sanitization by AATCC 90 HALO test method and for deodorization by wearing tests. The results show that the new developed latex spongee has warmth-keeping ratio of 2.5 times higher than that of the conventional spong and it has an excellent anti-bacteria effect. Actual wearing function tests also show that it improves significantly the performance of deodorization, sanitization, warmth-keeping and bulkiness.

  • PDF

Experimental Study for Keeping a Melting Pool in a Waste Pyrolysis Melting Incinerator (폐기물 열분해 용융소각로의 용탕 유지를 위한 실험적 연구)

  • Kim, Bong-Keun;Park, Ju-Won;Yu, Tae-U;Yang, Won;Jeun, Keum-Ha
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.151-155
    • /
    • 2006
  • The large amount of energy is consumed in a process for keeping the high temperature melting pool. For this reason, in addition to the wastes input to keep the high temperature melting pool, it is necessary for an auxiliary fuel and LOx to throw into the melting pool. So in this study, using a new melting furnace system, the experiments to keep the melting pool with minimal energy without throwing an auxiliary fuel and LOx was carried out. Also it is hoped that the results of the experiment will be available to analyze keeping a melting pool and behavior in a melting furnace.

  • PDF

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF