Performance Test for Automatic Exposure Control by Zone System (Zone System을 이용한 자동노출장치의 성능 측정에 관한 실험)

  • Kang, Hee-Doo;Pyo, Chang-Gi;Cha, Jung-Hee;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.57-63
    • /
    • 1998
  • AEC was designed to assist in the production of radiographs of equal density and to aid in the production f consistently high quality radiographs. Many improvements have been made in the AEC and these have helped to increase it's acceptance. Newer system (Falling load) control kVp and mA as well as exposure time. Authors have had experiments about the characteristics of AEC by Zone System. Zone System is the method to detection of photographic image qualify by control the photo print from Fred Archer and Ansel Adams. With the Zone System theory the experiments of density control, characteristics of phantom thickness and reproducibility of occupation rate of contrast media could make quality control of X-ray photography effectively in falling load system.

  • PDF

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

A Study of X-ray Output for Diagnostic X-ray Equipment (진단용 X선 발생 장치의 X선 출력에 관한 연구)

  • Ko, Shin-Gwan;Ahn, Bong-Seon;Jang, Sang-Sup;Choi, Jong-Woon;Shin, Young-Soon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Analysis of CT Image Quality Change according to Clinical Application Shielding Materials (임상 적용 차폐물질에 따른 선량 및 CT 화질 변화 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Among brain CT scan conditions including the lens, the tube voltage was changed to 80, 100, and 120 kVp and applied. The change in dose was analyzed using lead, lead goggles and barium sulfate silicon shielding materials, and the degree of influence of the shielding materials on image quality was compared and analyzed by applying the SNR, CNR, and SSIM index analysis methods. As a result, it was analyzed that although the dose was reduced by applying all shielding materials, the difference in dose reduction was not large (P > 0.05). In addition, as for the change in image quality due to the application of the shielding material, SNR and CNR were the highest when lead goggles were applied, and the structural similarity was measured to be the best as it was closest to the reference value of 1 in SSIM analysis. Therefore, based on the results of this study, it is thought that if more diverse shielding materials and clinical test results are derived and applied, it will be helpful for the clinical application criteria in the case of shielding utilization inspection.

Radiation Dose and Image Evaluation for Position Change in Low Extremity Teleography (하지전신계측검사에 자세의 변화에 따른 방사선량 및 영상평가)

  • Kim, Yeongcheon;Song, Jongnam;Choi, Namgil;Han, Jaebok
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.233-234
    • /
    • 2014
  • 하지전신계측검사(low extremity teleography)에서 자세 변화에 따른 중요장기의 방사선량을 측정하고 영상을 비교 분석하여 검사방법에 따른 유용성을 알아보고자 하였다. 대상은 하지전신계측검사를 시행한 성인남자 10명을 대상하였고 촬영조건은 관전압 73 kVp, 관전류량 32 mAs, SID 180 cm로 설정하였다. 방사선량 측정은 란도 팬텀을 이용하여 수정체, 갑상선, 생식선 부위에 유리선량계(ion chamber)를 부착한 후 전후방향자세와 후전방향자세를 각각 5번씩 시행하여 부위별로 방사선량을 측정한 후 Paired T-test로 비교 분석 하였다. 영상평가는 전후방향자세와 후전방향자세를 시행한 영상을 blind test를 실시하여 5점 척도로 평가하였다. 결과적으로 전후방향자세검사에 비해 후전방향자세검사가 수정체 약 6%, 갑상선 약 6%, 생식선에 미치는 방사선량을 약 27% 감소시킬 수 있으며 영상평가에서도 두 그룹 간에 큰 차이가 없어, 하지전신계측검사에서 전후방향자세검사보다 후전방향자세검사가 유용할 것으로 사료된다.

  • PDF

Bacillus cereus Clinical Isolates : Characteristics, Enterotoxin Production and Antimicrobial Susceptibility (임상 검체에서 분리된 Bacillus cereus의 성상, 장독소 생성 및 항균제 감수성)

  • Kim, Shin-Moo;Kim, Eun-Cheol;So, Hyang-Ah;Lee, Gyu-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.27-34
    • /
    • 2005
  • Biochemical characteristics, enterotoxin production and antimicrobial susceptibility were determined for 30 strains of Bacillus cereus isolated from stool specimens of diarrhea patients at an university hospital in Chulabuk-do province. Positive rate for VP reaction and citrate utilization were lower, (33 % and 40 % respectively) while the rates of acid production from mannitol, arabinose, and xylose were higher (17 %, 13 % and 3 % respectively) than those obtained by other investigators. The enterotoxin gene was detected in 18 of 30 isolates (60 %) by PCR, and the toxin was detected from all of the toxin gene-positive isolates by RPLA test. The agar dilution test showed that all isolates were resistant to penicillin G and 73 % were to cephalothin, but all were susceptible to ciprofloxacin, clindamycin, erythromycin, fusidic acid, gentamicin, rifampin, teracycline and vancomycin. We conclude that B. cereus isolates producing acid from mannitol, arabinose and xylose exist, that PCR can be used to detect enterotoxin genes rapidly and accurately, and that this organism is susceptible to various antimicrobial agents though not penicillin G and cephalothin.

  • PDF

Adhesion Properties of Rubber and Kevlar modified with Resorcinol-formaldehyde resin and Rubber Latex (Resorcinol-formaldehyde resin와 고무 latex에 의해 표면 개질된 Kevlar 섬유의 고무 접착 특성)

  • Lee, Soo;Ko, Young-Duk
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • Kevlar was chemically surface modified with resorcinol-formaldehyde(RF) prepolymer and VP rubber latex for application to high strength tirecords. RF prepolymer was easily obtained by polymerization at room temperature in the presence of a base catalyst. The mechanical and thermal properties of Kevlar were not significantly changed during surface treated under various conditions. The change of adhesion with rubber were investigated through H-test method. Maximum increase of adhesion force between rubber and Kevlar was obtained up to 40% than that of untreated one when the fiber was soaked in RFL dipping solution and thermally treated at $170^{\circ}C$ for 3 - 5min.

A Design of Piezo Driver IC for Auto Focus Camera System (디지털카메라의 자동초점제어를 위한 피에조 구동회로의 설계)

  • Lee, Jun-Sung
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.190-198
    • /
    • 2010
  • This paper describes a auto focus piezo actuator driver IC for portable digital camera. The 80[V] DC voltage is generated by a DC-DC converter and supplied to power of piezo moving control circuit. The voltage of piezo actuator needs range -20[V] to 80[V] proportional to 1[Vp-p] input control voltages. The dimensions and number of external parts are minimized in order to get a smaller hardware size. IIC(Inter-IC) interface logic is designed for data interface and it makes debugging easy, test for mass productions. The power consumption is around 40[mW] with supply voltage of 3.6[V]. This device has been fabricated in a 0.6[um] double poly, triple metal 100[V] BCD MOS process and whole chip size is 1600*1500 [$um^2$].

Isolation and Identification of Antagonistic Bacteria for Biological Control of Ginger Rhizome Rot Caused by Pythium zingiberum

  • Lee, Du-Ku;Shim, Jai-Sung;Shim, Hyeong-Kwon;Lee, Yong-Hoon;Lee, Wang-Hyu
    • Plant Resources
    • /
    • v.2 no.2
    • /
    • pp.81-87
    • /
    • 1999
  • Sixteen isolates showing relatively strong antagonicity against the ginger rhizome rot pathogen, Pythium zingiberum, were selected among the 155 isolates from ginger rhizome surfaces and rhizospheres of ginger cultivation fields in Wanju, Chonbuk. The isolate, 'HB 26-5'showing the strongest antagonicity was finally selected by testing duration of inhibition effect and pathogenicity to ginger. The isolated antagonistic microorganism, 'HB 26-5' was rod shape, gram positive and formed endospore. The isolate produced acids utilizing glucose, arabinose, xylose and mannitol, and acetoin at VP test, and grew anaerobically. Temperature range for growth was from 10 to 4$0^{\circ}C$ . Reaction to catalase and gelatin, hydrolysis were positive, and casein hydrolysis and indol production were negative. Based on the mycological characters and the fatty acid composition, it was identified as Bacillus polymyxa. The pathogenicity test of isolated Bacillus polymyxa 'HB 26-5'on 22 crop cultivars resulted that only the lettuce was influenced in germination, and the others were not affected.

  • PDF