• 제목/요약/키워드: junior college

검색결과 3,333건 처리시간 0.024초

사지(四肢) 단순촬영조건(單純撮影條件)의 관전압(管電壓)에 대(對)한 연구(硏究) (A Study on Kilovoltage in Radiographic Technique Factors of the Extremities)

  • 최종학;전만진;김영일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제3권1호
    • /
    • pp.29-35
    • /
    • 1980
  • The tube voltage in radiographic technique factors of the extremities was studied to use the acryl phantom and aluminum step wedge. It was the proper tube voltage that was over 55-60kV in the finger, over 65kV in the forearm and over 75kV in the knee joint.

  • PDF

분위기가스에 따른 YBaCuO 박막의 특성에 관한 연구 (A Study on the Properties of YBaCuO Thin films with Ambient Gas)

  • 최충석;신태현;조기선;박구범;김영조;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1193-1195
    • /
    • 1995
  • The superconducting properties of YBaCuO thin films prepared by pulsed laser deposition(PLD) have been investigated. The x-ray diffraction patterns of the films are substantially different from one another. The YBaCuO thin films manufactured at the 20% of Argon mixture ratio were indicated $T_c$(zero)=88.2 K, $T_c$(onset)=92.1 K, and $J_c=9.0{\times}10^4A/cm^2$(at 77.3K).

  • PDF

X선촬영에 있어서 관전압과 피사체가 선질 및 선량에 미치는 영향의 실험 (Influence of X-ray Tube Voltage and Object on X-ray Quality and Dose)

  • 허준;김창균;강홍석;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.41-46
    • /
    • 1984
  • Authors investigated an influence of x-ray tube voltage on x-ray quality and dose with using objects of various thickness, and obtained the results as follows: 1. Radiographic effects were influenced by tube voltages and objects. 2. Dose decrement rates hade more influence upon primary-rays than total x-rays at lower tube voltages. 3. The quality of transmitted x-rays was affected by tube voltages and thickness of objects. 4. Scattered-ray contents were proportional to tube voltages with using grid.

  • PDF

촬영조건의 교정에 관한 실험 (A Experimental Study on the Correction Methods of X-ray Exposure Factors)

  • 허준;김창균;이선숙;김학성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.67-70
    • /
    • 1984
  • Radiographic units have changeable factors in x-ray outputs, Therefore, an exposure factor by basic experimental study must be made out about each x-ray installation, but this is very intricate methods and not a practical business. Authors tried out a new method to make simple exposure factors. The first, we had a experimental object radiograph taken to find the output of each radiographic unit. The second, by obtained x-ray density we found the difference in x-ray output. and lastly, we made a new and simple correction method to use the obtained output and x-ray density.

  • PDF

응급환자(應急患者)의 흉부촬영(胸部撮影)에 관(關)한 고찰(考察) (An Experimental Study on the Chest Examination in Emergency Cases)

  • 박영선;신영순;고신관;김화곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.51-54
    • /
    • 1979
  • Research and Analisis for the qualities of chest films of emergency cases were completed in order to produce a valuable one of diagnostic necessity. It is resulted as follows; 1. Among the 3,505 cases of chest films, 47% of them was poor conditioned the reason was fowned as of unsuitable exposure. 2. It become the same condition when we increased 11.4% of KVp in full exhalation compare with the full inhalation of erect position and 20% after full exhalation and 4.3% after full inhalation in supine position. The result was that no difference between prone position and supine position was fowned. 3. When respiration volume is different, proper control of KVp is extremely needed.

  • PDF

알루미늄계단을 이용한 X선필름의 감도측정법에 관한 새로운 시도 (A New Approach in Sensitometry of X-ray Film to Use Aluminium Stepwedge)

  • 허준;김창균;강홍석;이선숙
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제6권1호
    • /
    • pp.35-41
    • /
    • 1983
  • Boot-Strap method is used to measure the sensitivity of X-ray film, but it is too complicated to design the plot and this method is generally a falling-off in the accuracy and the reproducibility. Authors made an attempt a new method to obtain the stable H-D curve, that is to say; Boot-Strap method used in combination with distance-change method, and the accuracy and the reproducibility.

  • PDF

증감지에 따른 피사체 대조도의 변화 (Effect of Intensifying Screens to Subject Contrast)

  • 이인자;허준;강홍석;윤철호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제13권2호
    • /
    • pp.27-30
    • /
    • 1990
  • It is an experimental report about object contrast according to the Kinds of screen and obtained results as follows : 1. In the same object radiography, use acquired the difference of the object contrast between LT-II ($CaWO_{4}\;system$) and G4 (Gd system) screens. 2. object contrast more decreased in Gd system screen than $CaWO_{4}$, and object contrast controlled by X-ray tube voltage. 3. The difference of object contrast seen clearly in 80 kVp.

  • PDF

증감지의 발광스펙트럼에 따른 특성곡선의 변화 (Change of Characteristic Curves using Light Emission Spectrum of the Intensifying Screens)

  • 윤철호;강홍석;이인자;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제13권2호
    • /
    • pp.21-25
    • /
    • 1990
  • This report is study about difference of H-D curve in regular film and ortho type film, and obtained results as follows : 1. In the blue-color emission intensifying screen, ortho type films and in the green-color emission intensifying screens, regular type are decreased in their gradient. 2. When joint use of regular type film and ortho type film, the gradient difference not seen in blue color screen. 3. The gradient difference seen clearly in G4, KM screens(green color emission intensifying). Especially, in part of high film density, the gradient difference are great. So we have to right use of screen and film because not matched used of theare the sensitivity and gradient are decrease.

  • PDF