• Title/Summary/Keyword: joint power

Search Result 984, Processing Time 0.031 seconds

A proposal of new MOE to assess the combat power synergistic effect of warfare information system. (전장 정보체계의 전투력 상승효과 측정을 위한 새로운 MOE 제안)

  • Lee, Yong-Bok;Kim, Yong-Heup;Lee, Jae-Yeong
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2008.10a
    • /
    • pp.104-112
    • /
    • 2008
  • In modern war information system development makes battlefield materialize, and combat factors can maximize combat power exhibition as that apply synchronization. Information system is the core of combat power operation under NCW(Network centric Warfare). This paper proposed a new MOE(Measure of Effectiveness) that can assess the combat power synergistic effect of information system at the theater joint fire operation in NCW environment. This methodology applied the rule of Newton's second law $F=(m{\Delta}{\upsilon})/t{\Rightarrow}(M{\upsilon}I)/T$) Details factor in combat power evaluation is as following. (1) M : Network power; (2) v : Movement velocity; (3) I : Information superiority; (4) T : C2(command and control) time. We applied this methodology to the "JFOS-K(Joint Fire Operating System-Korea) in Joint Chief of Staff" in the real military affair section.

  • PDF

The effect of whole body vibration on lower joints in vertical jump (전신진동운동이 수직점프 시 하지관절에 미치는 영향)

  • Yi, Jae-Hoon
    • Journal of Digital Convergence
    • /
    • v.14 no.6
    • /
    • pp.513-518
    • /
    • 2016
  • The Mechanisms of whole body vibration on the human body is not clearly presented despite of the research result and there is not enough research that shows the effects of vibration on the kinetic changes of the lower joint. Therefore, this study focuses on finding out which lower joint is related with kinetic vertical jump ability. Five male and five female who didn't have orthopedic history were selected as the subjects. The subjects carried out three squat jumps before and after 5minutes of 30Hz whole body vibration. We have utilized a 3D motion analysis system to analyze the kinetic changes of the lower joint in the vertical jump. The height of subjects squat jump was improved after whole body vibration treatment. Also, the lower joint moment and power increased. However, there were no statistically significant changes in GRF, hip joint moment and power after the whole body vibration proved to have positive effect on the ankle and knee joints but showed negative effect on the hip joint.

Analysis of the Differences of the Shock Attenuation Strategy between Double-leg and Single-leg Landing on Sagittal Plane using Statistical Parametric Mapping (Statistical Parametric Mapping을 이용한 시상면에서의 양발 착지와 외발 착지의 전략 차이)

  • Ha, Sunghe;Park, Sang-Kyoon;Lee, Sae Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.4
    • /
    • pp.255-261
    • /
    • 2019
  • Objective: The purpose of this study was to investigate differences of shock attenuation strategies between double-leg and single-leg landing on sagittal plane using statistical parametric mapping. Method: Nine healthy female professional soccer players (age: 24.0±2.5 yrs, height: 164.9±3.3 cm, weight: 55.7±6.6 kg, career: 11.2±1.4 yrs) were participated in this study. The subjects performed 10 times of double-leg and single-leg landing from the box of 30 cm height onto force plates respectively. The ground reaction force, angle, moment, angular velocity, and power of the ankle, knee, and hip joint on sagittal plane was calculated from initial contact to maximum knee flexion during landing phase. Statistical parametric mapping was used to compare the biomechanical variables of double-leg and single-leg landing of the dominant leg throughout the landing phase. Each mean difference of variables was analyzed using a paired t-test and alpha level was set to 0.05. Results: For the biomechanical variables, significantly increased vertical ground reaction force, plantarflexion moment of the ankle joint, negative ankle joint power and extension moment of the hip joint were found in single-leg landing compared to double-leg landing (p<.05). In addition, the flexion angle and angular velocity of the knee and hip joint in double-leg landing were observed significantly greater than single-leg landing, respectively (p<.05). Conclusion: These findings suggested that negative joint power and plantarflexion moment of the ankle joint can contribute to shock absorption during single-leg landing and may be the factors for preventing the musculoskeletal injuries of the lower extremity by an external force.

A Study on Start·Stop System at Water Turbine-Generator for Tidal Power Plant (조력발전용 수차발전기의 기동·정지시스템에 관한 연구)

  • Oh, Min-Hwan;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.113-118
    • /
    • 2014
  • Tidal power is one of new and renewable energy sources. Tidal power is generated by using the gap in the water level between the water outside and inside the embankment. All tidal power plant in Korea were being operated by import of turn-key from abroad. The know-how and technology which are the most important to build predictive control system has become increasingly difficult to obtain from advanced countries because most of them avoid to transfer, which the domestic development of the control system is needed. In this paper, a study on start stop system at water turbine-generator for tidal power plant at the beginning of development was presented. For improvement the efficiency and develope of core technology of the start stop system, the technique and characteristics of tidal power, modeling, maximum generation calculation method, and optimal control of joint control system in Sihwa tidal power plant were studied.

Isokinetic Strength Capacity Between Elite Athletes and Taekwondo Player (엘리트 육상선수와 태권도 선수의 등속성 운동능력에 관한 비교 연구)

  • Kim, Hyun-Mi;Lee, So-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2691-2697
    • /
    • 2011
  • The purpose of the dissertation is to offer basic data available for being conducive to application of a training program by comparatively analyzing the players' physical strength, the knee joint, a hip joint, power of the trunk joint and muscle power in order to study isokinetic strength and muscle power between short distance athletes and Taekwondo players. This study measured peak power, %Body weight peak power, always power, and %Body weight peak power targeting 8 male athletes and 8 male Taekwondo players who warmed up 10 minutes before from the test to reduce repulsion and unfamiliarity at the instrument. The power of the knee joint($60^{\circ}$/sec), muscle power($180^{\circ}$/sec), were measured by using HUNOM(U.S.A). As a result of the physical strength, statistically, short distance athletes were indicated to be better in muscle strength, muscular endurance than Taekwondo players, and there was no significant difference between flexibility, power, and muscular endurance. Although the short distance athletes were indicated to be better in right and left muscle strength of knee joint than Taekwondo player, there was no significant difference and Taekwonde players were indicated to be higher at the right and left muscle power than short distance athletes.

Clinical Study on Effect of Rainbow Power Therapy on Osteoarthritis in Knee Joint (Rainbow Power 요법 시술이 퇴행성 슬관절염에 미치는 임상 효능연구)

  • Sung, Hyun-Jae;Kim, Ee-Hwa;Hwang, Jae-Wok;Ryu, Chungr-Yeul
    • Korean Journal of Acupuncture
    • /
    • v.20 no.4
    • /
    • pp.85-98
    • /
    • 2003
  • Objective : This study is designed to find out the effects of Rainbow Power therapy on knee joint with osteoarthritis. Methods : Patient with the osteoarthritis of knee joints are divided into Rainbow Power therapy group(20 people) and none-Rainbow Power therapy group(20 people). After treatment, we evaluated the effect per each group. Results : 1. Fifty and Sixty aged patients were the most in the Rainbow Power group(30% each) and sixty aged patients were the most in the None-Rainbow Power group(45%). 2. In the both groups, 1-3 years duration of disease was the most(40%, 45% each). 3. In the none-Rainbow Power group, patients improved (Lysholm score : $49.20{\pm}11.54{\rightarrow}63.90{\pm}9.54$, p<0.05), but, did not improved in the part of squatting and dystrophy. In the Rainbow Power group, patients improved(Lysholm score : $46.55{\pm}9.89{\rightarrow}80.90{\pm}13.78$, p<0.05), but, did not improved only in the part of dystrophy. 4. The effects of treatment by VNRS were follow : After treatment, $4.10{\pm}1.22$ in Rainbow Power Group and $4.55{\pm}1.15$ in none-Rainbow Power group. 5. The effects of treatment by nine points scale were follow : In the Rainbow Power group, the Excellent was 7 cases(35%), the Good was 9 cases(45%), the Fair was 4 cases(20%) and there was no Poor. The Excellent was 6 cases(30%), the Good was 8 cases(40%), the Fair was 6 cases(30%) and there was no Poor.

  • PDF

DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination (HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가)

  • Kwon, Ik-Soo;Hwang, Jae-Sang;Koo, Jae-Hong;Sakamoto, Kuniaki;Lee, Bang-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • A outdoor termination installed at the outdoor substation is required to connect undergroud cables and overhead transmission lines. The joint box for AC transmission system is already developed and widely used to interconnect overhead and undergroud systems. But the development of the joint box for DC transmission system was only introduced from China and Japan, but theire developemnt staus and core technologies were not fully reported. In order to implement HVDC systems connecting ovehead transmission lines and undergroud cables, a outdoor termination should be developed, but the detailed specifications and information of this device were not reported. It is estimated that the development of the joint box for DC environment has some technical obstacles including insulating materials, electric field mitigation, thermal temperature rise, and space charge accumuations. Among this, the most important one is the DC elctrical insualtion design. Therefore, in order to investigate the DC elctrical insualton design of outdoor termination, the design of AC slip-on type outdoor termination is reffered, and DC electric field analysis performed to verify the possiblity of application of AC joint box into DC joint box. Especially for DC electric field analysis, temperature rise of insualting materials of a joint box was considered, because the conductivity of materials could be changed due to temperature rise. Furthermore, DC electric field analysis considering transinet state, and polarity reversal state were also investigated to verify which state is the most severe condition for the DC joint box. From the simualtion resulsts, it was shown that the value and the position of maximum electric field was obtained comparing AC state, DC state without temperaure rise, and DC state with temperaure rise. And it was confimred that severe DC electric field was observed considing temperaure rise. Finally, in order to reduce DC eletric field intensifation, different configuration of the joint box was applied and it was not possible to obtain satisfactory results. It means that the slight change of configuration of AC joint box was not the suitable soluton for DC joint box. It is essential to establish novel DC insulaton design skills and method for DC joint box to commercialze this product in the near future.

A Genetic Approach for Joint Link Scheduling and Power Control in SIC-enable Wireless Networks

  • Wang, Xiaodong;Shen, Hu;Lv, Shaohe;Zhou, Xingming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1679-1691
    • /
    • 2016
  • Successive interference cancellation (SIC) is an effective means of multi-packet reception to combat interference at the physical layer. We investigate the joint optimization issue of channel access and power control for capacity maximization in SIC-enabled wireless networks. We propose a new interference model to characterize the sequential detection nature of SIC. Afterward, we formulize the joint optimization problem, prove it to be a nondeterministic polynomial-time-hard problem, and propose a novel approximation approach based on the genetic algorithm (GA). Finally, we discuss the design and parameter setting of the GA approach and validate its performance through extensive simulations.

A Study on Fault Prediction Algorithm and Failure Instance Analysis of Electric Power Relay (전력릴레이 고장사고 사례분석 및 고장예측 알고리즘 연구)

  • Kim, Yong-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.15-16
    • /
    • 2015
  • According to 2014 fire statistical yearbook in the National Fire Data System, a main cause of fire is electrical fire except carelessness fire. Joint/contact badness is the one of the main cause of electrical fire. Furthermore, power relays which are used in electric panel board, motor control center and automation controller, are main element of automation system in the industry field. Overload, voltage unbalance and open-phase due to joint/contact badness of terminal make electric accidents or electrical fires. In order to prevent joint/contact badness of terminal, this paper proposes a sensing circuit of chattering, tracking, arc current, voltage unbalance and open-phase etc. Some experimental tests of the proposed apparatus confirm practicality and validity of the theoretical results.

  • PDF