• 제목/요약/키워드: joint measurement

검색결과 805건 처리시간 0.035초

실하중 이력에 의한 조인트의 동적강도해석 (Dynamic Stress Analysis of joint by Practical Dynamic Load History)

  • 송준혁;강희용;양성모
    • 한국공작기계학회논문집
    • /
    • 제10권5호
    • /
    • pp.118-123
    • /
    • 2001
  • Most structures of automobile are composed of many substructures connected to one another by various types of mechanical joints. In automotive engineering, it is important to study these connected structures under various dynamic farces for the evaluations of fatigue life and stress concentration exactly. It is rarely obtained the accurate load history of specified positions because of the errors such as modeling, measurement, and etc. In the beginning of design, exact load data are actually necessary for the fatigue strength and life analysis to minimize the cost and time of designing. In this paper, the procedure of practical dynamic load determination is developed by the combination of the principal stresses of F.E. analysis and experiment. Inverse problem and least square pseudo inverse matrix are adopted to obtain an inverse matrix of analyzed stresses matrix. Pseudo-Practical dynamic load was calculated for Lab. Test of sub-structure. GUI program(PLODAS) was developed for whole of above procedure. This proposed method could be extended to any geometric shape of structure.

  • PDF

매선 요법 3회 시술 후 안면 피부 변화에 대한 개선 효과 : 10례 증례연구 (Anti Wrinkle Effect of Needle-Embedding Therapy: a Case Series)

  • 강경원;박정용;김주희;최선미;정금용
    • 대한한방부인과학회지
    • /
    • 제31권1호
    • /
    • pp.147-154
    • /
    • 2018
  • Objectives: This study aims to examine the improvement against facial wrinkles after needle-embedding therapy. Methods: The study participants were 10 women treated with needle-embedding therapy in the Korean Medical Clinic from September, 2011 to August, 2014. The subjects were treated every ten days for twenty days, totally three times, and the result of treatment was evaluated five times, such as pre-treatment, after each treatments, one month and two months later of the last treatment with ARAMO-SG. Results: 1. Depth and range of facial wrinkles, facial skin pore test, and sensitivity test were visibly improved after needle-embedding therapy and follow-up compared pre-treatment (p<0.05). 2. The significant improvements in facial skin texture test was not observed and sustained until the follow-up measurement at 2 months. 3. Any adverse reaction related to needle-embedding therapy did not happen. Conclusions: This study suggests that needle-embedding therapy can improve facial wrinkles. The positive results of this study support the requirement for additional research investigating the efficacy of needle-embedding therapy in women.

원위 경비 인대 결합 고정 긴장도와 기간이 나사못 제거 후 이개 및 임상 증상에 미치는 영향 (The Impacts of Fixation Tightness and Duration on the Remnant Syndesmotic Widening and Clinical Symptom after Removal of Screws)

  • 배서영;손수인;성민규
    • 대한족부족관절학회지
    • /
    • 제17권4호
    • /
    • pp.264-271
    • /
    • 2013
  • Purpose: We aimed to analyze the effect of fixation tightness of the syndesmotic screw and its indwelling period on the recurrence of the syndesmosis widening after screw removal and the clinical outcomes. Materials and Methods: Forty consecutive patients with acute syndesmotic injury were retrospectively reviewed. The tibiofibular clear space is measured by digitalized measurement tool on serial radiographs. We analyzed the effect of time from trauma to fixation, syndesmotic screw indwelling duration, and fixation methods. Residual symptoms at the last follow up were evaluated. The student t-test, correlation test, and chi-square test were used for statistical analysis. Results: Eighteen ankles (45%) had recurrent syndesmosis widening (greater than 5% compared to the contralateral side). Seven patients had pain and five had limitation of motion in the ankle joint. Fixation tightness had significant effect on reducing the recurrence while the severity of the initial widening, time to fixation, and duration of fixation did not affect the outcome. Conclusion: Tight fixation of syndesmotic screw is essential for achieving final syndesmotic stability and reducing recurrence.

Stochastic Stability Analysis of the Power System Incorporating Wind Power using Measurement Wind Data

  • Parinya, Panom;Sangswang, Anawach;Kirtikara, Krissanapong;Chenvidhya, Dhirayut
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1110-1122
    • /
    • 2018
  • This paper proposes an alternative method to evaluate the effect of wind power to the power system stability with small disturbance. Alternatively, available techniques for stability analysis of a power system based on deterministic methods are less accurate for high penetration of wind power. Numerical simulations of random behaviors are computationally expensive. A stochastic stability index (SSI) is proposed for the power system stability evaluation based on the theory of stochastic stability and energy function, specifically the stochastic derivative of the relative well-defined energy function and the critical energy. The SSI is implemented on the modified nine-bus system including wind turbines under different conditions. A doubly-fed induction generator (DFIG) wind turbine is characterized and modeled using measured wind data from several sites in Thailand. Each of the obtained wind power data is analyzed. The wind power effect is modeled considering the aggregated effect of wind turbines. With the proposed method, the system behavior is properly predicted and the stability is quantitatively evaluated with less computational effort compared with conventional numerical simulation methods.

와이어 본더용 Horn-Holder Assembly의 접촉 해석 (Contact Analysis on a Born-Holder Assembly for Wire Bonding)

  • 장창수;안근식;김영준;곽동옥;부성운
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.2008-2017
    • /
    • 2002
  • Joint structure of a transducer horn-holder assembly fur a wire bonder was examined through FEM contact analysis. A three dimensional modeling and analysis was carried out to survey the internal physics of this structure and to prove the accuracy of a computation compared to a measurement. After validation, a simple two dimensional model was built fur various parametric study considering the efficiency and speed of the computation. Several factors such as boundary conditions, a modeling boundary, mesh density and so on, were considered to obtain consistency with three dimensional analysis. An arc angle and a position of each holder boss were chosen as design parameters. A design of experiment was applied to find out an optimized design of the holder geometry. As a result, a guideline for holder boss design was suggested and main factors and their influence on stress concentration in the transducer horn were surveyed.

Joint Spatial-Temporal Quality Improvement Scheme for H.264 Low Bit Rate Video Coding via Adaptive Frameskip

  • Cui, Ziguan;Gan, Zongliang;Zhu, Xiuchang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제6권1호
    • /
    • pp.426-445
    • /
    • 2012
  • Conventional rate control (RC) schemes for H.264 video coding usually regulate output bit rate to match channel bandwidth by adjusting quantization parameter (QP) at fixed full frame rate, and the passive frame skipping to avoid buffer overflow usually occurs when scene changes or high motions exist in video sequences especially at low bit rate, which degrades spatial-temporal quality and causes jerky effect. In this paper, an active content adaptive frame skipping scheme is proposed instead of passive methods, which skips subjectively trivial frames by structural similarity (SSIM) measurement between the original frame and the interpolated frame via motion vector (MV) copy scheme. The saved bits from skipped frames are allocated to coded key ones to enhance their spatial quality, and the skipped frames are well recovered based on MV copy scheme from adjacent key ones at the decoder side to maintain constant frame rate. Experimental results show that the proposed active SSIM-based frameskip scheme acquires better and more consistent spatial-temporal quality both in objective (PSNR) and subjective (SSIM) sense with low complexity compared to classic fixed frame rate control method JVT-G012 and prior objective metric based frameskip method.

하이브리드 방식 (CNC+Laser)을 이용한 폴리머용접공정 (Hybrid (CNC+Laser) Process for Polymer Welding)

  • 유종기;이춘우;최해운
    • Journal of Welding and Joining
    • /
    • 제28권3호
    • /
    • pp.42-48
    • /
    • 2010
  • Polycarbonate (PC) and Acrylonitrile Butadiene Styrene (ABS) were welded by a combination of a diode laser and a CNC machining center. Laser beam delivered through the transparent PC and was absorbed in an opaque ABS. Polymers were melted and joined by absorbed and conducted heat. Experiments were carried out by varying working distance from 44mm to 50mm for the focus spot diameter control, laser input power from 10W to 25W, and scanning speed from 100 to 400mm/min. The weld bead and cross-section were analyzed for weld quality, and tensile results were presented through the joint force measurement. With focus distance at 48mm, laser power with 20W, and welding speed at 300mm/min, experimental results showed the best welding quality which bead size was measured to be 3.75mm. The shear strength at the given condition was $22.8N/mm^2$. Considering tensile strength of ABS is $43N/mm^2$, shear strength was sufficient to hold two materials. A single process was possible in a CNC machining system, surface processing, hole machining and welding. As a result, the process cycle time was reduced to 25%. Compared to a typical process, specimens were fabricated in a single process, with high precision.

The Effect of Thoracic Joint Mobilization on the Changes of the Thoracic Kyphosis Angle and Static and Dynamic Balance

  • Jeong, Hae-Jin;Kim, Byeong-Jo
    • 대한의생명과학회지
    • /
    • 제25권2호
    • /
    • pp.149-158
    • /
    • 2019
  • The objective of this study was to evaluate the effects of thoracic mobilization (TM) on the angle of thoracic kyphosis, and static and dynamic balances by application period. The subjects of this study were 18 adult males and females (${\geq}20years\; old$) who had the angle of thoracic kyphosis equal to or higher than $40^{\circ}$. A pre-test was conducted for all subjects and TM was carried out. Data were collected before the intervention, 3 weeks after the intervention, and 6 weeks after the intervention. It was measured three times per measurement and mean values were used for the analysis. The results of this study showed that the angle of thoracic kyphosis significantly (P<.05) decreased after applying TM. However, the migration area ($mm^2$) of the center of pressure (COP) in the static balance did not vary significantly. In the case of the dynamic balance, when eyes were open, the migration area ($mm^2$) of the COP significantly (P<.05) decreased after 3 weeks. When eyes were open, the migration area ($mm^2$) of the COP significantly (P<.05) decreased after 3 weeks and 6 weeks. Therefore, an intervention for improving the human body alignment and balance should be applied for a long-term, rather than a short-term, in order to be effective.

다양한 웨어러블 디바이스를 활용한 크로스컨트리스키 실시간 위치 추적: 사례 연구 (Real-time Location Tracking Analysis of Cross-country Skiing using Various Wearable Devices: A Case Study)

  • Hwang, Jinny;Kim, Jinhae;Kim, Hyeyoung;Moon, Jeheon;Lee, Jusung;Kim, Jinhyeok
    • 한국운동역학회지
    • /
    • 제29권1호
    • /
    • pp.1-8
    • /
    • 2019
  • Objective: The purpose of this study was to confirm that the cross-country ski sprint course in PyeongChang, where the 2018 Winter Olympics course was to utilize wearable devices equipped with inertial measurement unit (IMU), global positioning system (GPS) and heart rates sensor. Method: For the data collection, two national level cross-country (XC) skiers performed classic technique on the entire sprint course. We analyzed cycle characteristics, range of motion on double poling (DP) technique, average velocity, and displacement of 3 points according to the terrain. Results: The absolute cycle time gradually decreased during starting, middle and finish sections. While the length of the DP increased and the heart rates tended to increase for men skier. In addition, the results indicated that range of motion of knee joint during starting and finish section decreased more than middle section. The errors of latitude and longitude data collected through GPS were within 3 m from 3 points. Conclusion: Through the first case study in Korea, which analyzed the location and condition of XC skiers in the entire sprint course in real time, confirmed that feedback was available in the field using various wearable sensors.

The Joint analysis of galaxy clustering and weak lensing from the Deep Lens Survey to constrain cosmology and baryonic feedback

  • 윤미진;지명국
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.79.2-79.2
    • /
    • 2019
  • Based on three types of 2-point statistics (galaxy clustering, galaxy-galaxy lensing, and cosmic shear power spectra) from the Deep Lens Survey (DLS), we constrain cosmology and baryonic feedback. The DLS is a deep survey, so-called a precursor to LSST, reaching down to ~27th magnitude in BVRz' over 20 deg2. To measure the three power spectra, we choose two lens galaxy populations centered at z ~0.27 and 0.54 and two source galaxy populations centered at z ~0.64 and 1.1, with more than 1 million galaxies. We perform a number of consistency tests to confirm the reliability of the measurements. We calibrated photo-z estimation of the lens galaxies and validated the result with galaxy cross-correlation measurement. The B-mode signals, indicative of potential systematics, are found to be consistent with zero. The two cosmological results independently obtained from the cosmic shear and the galaxy clustering + galaxy-galaxy lensing measurements agree well with each other. Also, we verify that cosmological results between bright and faint sources are consistent. While there exist some weak lensing surveys showing a tension with Planck, the DLS constraint on S8 agrees nicely with the Planck result. Using the HMcode approach derived from the OWLS simulation, we constrain the strength of baryonic feedback. The DLS results hint at the possibility that the actual AGN feedback may be stronger than the one implemented in the current state-of-the-art simulations.

  • PDF