High Quality Network and Device Aware Multimedia Content Delivery for Mobile Cloud

  • Saleem, Muhammad;Saleem, Yasir
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.10
    • /
    • pp.4886-4907
    • /
    • 2019
  • The use of mobile devices is increasing in multimedia applications. The multimedia contents are delivered to mobile users over heterogeneous networks. Due to fluctuation in bandwidth and user mobility, the service providers are facing difficulties in providing Quality of Service (QoS) guaranteed delivery for multimedia applications. Multimedia applications depend on QoS parameters such as delay, bandwidth, and jitter to offer better user experience. The existing schemes use the single source and multisource delivery but are unable to balance between stream quality and network congestion for mobile users. We proposed a Quality Oriented Multimedia Content Delivery Scheme (QOMCDS) for the mobile cloud to deliver better quality multimedia contents for the mobile user. The multimedia contents are delivered to the mobile device based on the device's parameters and network environment. The objective video quality assessment models like Peak Signal-to-Noise Ratio (PSNR), Structural Similarity (SSIM), and Video Quality Measurement (VQM) are used to measure the quality of the video. The client side Quality of Experience metric such as Startup delay, Rebuffering events, and Bitrate switch count was used for evaluation. The proposed scheme is evaluated using dash.js and is compared to existing schemes. The results show significant improvement over existing multimedia content delivery schemes.

One-Way Delay Estimation Using One-Way Delay Variation and Round-Trip Time (단방향 지연 변이와 일주 지연을 이용한 양단간의 단방향 지연 추정)

  • Kim, Dong-Keun;Lee, Jai-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.1
    • /
    • pp.175-183
    • /
    • 2008
  • QoS-support technology in networks is based on measuring QoS metrics which reflect a magnitude of stability and performance. The one-way delay measurement of the QoS metrics especially requires a guarantee of clock synchronization between end-to-end hosts. However, the hosts in networks have a relative or absolute difference in clock time by reason of clock offsets. flock skews and clock adjustments. In this paper, we present a theorem, methods and simulation results of one-way delay and clock offset estimations between end-to-end hosts. The proposed theorem is a relationship between one-way delay, one-way delay variation and round-trip time And we show that the estimation error is mathematically smaller than a quarter of round-trip time.

  • PDF

Effects of Abdominal Respiration and Self Voice Feedback Therapy on the Voice Improvement of Patients with Vocal Nodules (복식호흡 훈련과 Self Voice Feedback 프로그램이 성대결절 환자의 음성개선에 미치는 효과)

  • Kwon, Soon-Bok;Wang, Soo-Geun;Yang, Byung-Gon;Jeon, Gye-Rok
    • Speech Sciences
    • /
    • v.13 no.3
    • /
    • pp.133-149
    • /
    • 2006
  • This study attempted to compare acoustic parameters, physiological observation and perceptual evaluation values obtained from the treatment and control groups in order to find out which of the self voice feedback therapies was better and which methods to train them were more effective. The experimental group carried out various self voice feedback therapies while the control group did only vocal hygiene. The acoustic measurement and voice manipulation for providing the patients visual, auditory feedback were done by a speech analysis software, Praat. The authors designed vocal hygiene, abdominal respiration and Praat self voice feedback therapies and applied them to 15 patients while applying only one vocal hygiene to 15 of the control group. For the purpose of examining the degree of their voice improvement after the treatment, pre- mid- and final evaluations were made for the two groups at the beginning, the 6th week and immediately after the 8th treatment session. Results of this study were as follows: The treatment group showed much improvement after receiving the voice treatment. In particular, acoustical and physiological indices from the optical endoscopy, pitch variation(Jitter), amplitude variation (Shimmer), maximum phonation time(MPT), and psychoacoustic evaluation showed statistically significant improvements over the control groups.

  • PDF

A Wide-range Tunable Wavelength-stabilization Technique for Semiconductor Lasers

  • Chen, Han;Qiao, Qinliang;Min, Jing;He, Cong;Zhang, Yuanyuan
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.384-390
    • /
    • 2021
  • This paper presents a wide-range tunable wavelength-locking technology based on optoelectronic oscillation (OEO) loops for optical fiber sensors and microwave photonics applications, explains the theoretical fundamentals of the design, and demonstrates a method for locking the relative wavelength differences between a leader semiconductor laser and its follower lasers. The input of the OEO loop in the proposed scheme (the relative wavelength difference) determines the radio-frequency (RF) signal frequency of the oscillation output, which is quantized into an injection current signal for feedback to control the wavelength drift of follower lasers so that they follow the wavelength change of the leader laser. The results from a 10-hour continuous experiment in a field environment show that the wavelength-locking accuracy reached ±0.38 GHz with an Allan deviation of 6.1 pm over 2 hours, and the wavelength jitter between the leader and follower lasers was suppressed within 0.01 nm, even though the test equipment was not isolated from vibrations and the temperature was not controlled. Moreover, the tunable range of wavelength locking was maintained from 10 to 17 nm for nonideal electrical devices with limited bandwidth.

Guidance to the Praat, a Software for Speech and Acoustic Analysis (음성 및 음향분석 프로그램 Praat의 임상적 활용법)

  • Seong, Cheol Jae
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.2
    • /
    • pp.64-76
    • /
    • 2022
  • Praat is a useful analysis tool for linguists, engineers, doctors, speech-language pathologits, music majors, and natural scientists. Basic parameters including duration, pitch, energy and perturbation parameters such as jitter and shimmer can be easily measured and manipulated in the sound editor. When a more in-depth analysis is needed, it is recommended to understand the advanced menus of the object window and learn how to use them. Among the object window menus, vowel formant analysis, spectrum analysis, and cepstrum analysis can be cited as useful ones in the clinical field. The spectrum object can be usefully used for voice quality measurement and diagnosis of patients with voice disorders by showing the energy distribution according to frequency axis (domain). A cepstrum object is useful for speech analysis when periodicity of the sound object is not measurable. The low to high ratio obtained from the spectral object and the CPPs measured from the cepstrum object have attracted many researchers, and it has been proven that the CPPs measured in Praat are relatively excellent.

A Study on QoS Measurement & Evaluation for MPEG Transmission in Network (통신망에서 MPEG 영상 전송을 위한 QoS 측정 및 평가에 관한 연구)

  • Suh Jae-Chul
    • Journal of Digital Contents Society
    • /
    • v.3 no.1
    • /
    • pp.101-111
    • /
    • 2002
  • Lately development of network around Internet expands range of data traffic to multimedia information, and so for the guarantee of multimedia services end-to-end QoS(Quality of Service) must service because comparing with existing Internet service can not support For satisfying those QoS requirements, network have to guarantee not only network on parameter, such as delay, jitter, throughput but also system resources like CPU utilization, memory usage. Therefore it is urgent to develop QoS based middleware to distribute multimedia data and maximize network utilization in the limited resource environment. And it must be necessary of network to provide end-to-end QoS(Quality of Service) for multimedia applications. Multimedia applications want that QoS which satisfy their own service properties be guaranteed Then, We must analyze those necessary QoS requirements md define QoS parameter which specify as two viewpoint, user's and network's perspective. Therefore network provider supplying network for usual user and university, enterprise must want to find about their own network performance and problem. It is essential for network manager to want to use a tool like this. On the basis of technique about QoS test-bed in the AIM network, We studied on the method of QoS measurement and management about end-to-end connection in the Internet. We measured network status about end-to-end connection and analyze the result of performance.

  • PDF

Conversational Quality Measurement System for Mobile VoIP Speech Communication (모바일 VoIP 음성통신을 위한 대화음질 측정 시스템)

  • Cho, Jae-Man;Kim, Hyoung-Gook
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.71-77
    • /
    • 2011
  • In this paper, we propose a conversational quality measurement (CQM) system for providing the objective QoS of high quality mobile VoIP voice telecommunication. For measuring the conversational quality, the VoIP telecommunication system is implemented in two smart phones connected with VoIP. The VoIP telecommunication system consists of echo cancellation, noise reduction, speech encoding/decoding, packet generation with RTP (Real-Time Protocol), jitter buffer control and POS (Play-out Schedule) with LC (loss Concealment). The CQM system is connected to a microphone and a speaker of each smart phone. The voice signal of each speaker is recorded and used to measure CE (Conversational Efficiency), CS (Conversational Symmetry), PESQ (Perceptual Evaluation of Speech Quality) and CE-CS-PESQ correlation. We prove the CQM system by measuring CE, CS and PESQ under various SNR, delay and loss due to IP network environment.

Scanning Rayleigh Doppler Lidar for Wind Profiling Based on Non-polarized Beam Splitter Cube Optically Contacted FPI

  • Zheng, Jun;Sun, Dongsong;Chen, Tingdi;Zhao, Ruocan;Han, Yuli;Li, Zimu;Zhou, Anran;Zhang, Nannan
    • Current Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.195-202
    • /
    • 2018
  • A Scanning Rayleigh Doppler lidar for wind profiling based on a non-polarized beam splitter cube optically contacted FPI is developed for wind measurement from high troposphere to low stratosphere in 5-35 km. Non-polarized beam splitter cube optically contacted to the FPI are used for a stable optical receiver. Zero Doppler shift correction is used to correct for laser or FPI frequency jitter and drift and the timing sequence is designed. Stability of the receiver for Doppler shift discrimination is validated by measuring the transmissions of FPI in different days and analyzed the response functions. The maximal relative wind deviation due to the stability of the optical receiver is about 4.1% and the standard deviation of wind velocity is 1.6% due to the stability. Wind measurement comparison experiments were carried out in Jiuquan ($39.741^{\circ}N$, $98.495^{\circ}E$), Gansu province of China in 2015, showing good agreement with radiosonde result data. Continuous wind field observation was performed from October 16th to November 12th and semi-continuous wind field of 19 nights are presented.

Distance Measurement of Small Moving Object using Infrared Stereo Camera (적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정)

  • Oh, Jun-Ho;Lee, Sang-Hwa;Lee, Boo-Hwan;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • This paper proposes a real-time distance measurement system of high temperature and high speed target using infrared stereo camera. We construct an infrared stereo camera system that measure the difference between target and background temperatures for automatic target measurement. First, the proposed method detects target region based on target motion and intensity variation of local region using difference between target and background temperatures. Second, stereo matching by left and right target information is used to estimate disparity about real-time distance of target. In the proposed method using infrared stereo camera system, we compare distances in three dimension trajectory measuring instrument and in infrared stereo camera measurement. In this experiment from three video data, the result shows an average 9.68% distance error rate. The proposed method is suitable for distance and position measurement of varied targets using infrared stereo system.

Analysis of Eye-safe LIDAR Signal under Various Measurement Environments and Reflection Conditions (다양한 측정 환경 및 반사 조건에 대한 시각안전 LIDAR 신호 분석)

  • Han, Mun Hyun;Choi, Gyu Dong;Seo, Hong Seok;Mheen, Bong Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.5
    • /
    • pp.204-214
    • /
    • 2018
  • Since LIDAR is advantageous for accurate information acquisition and realization of a high-resolution 3D image based on characteristics that can be precisely measured, it is essential to autonomous navigation systems that require acquisition and judgment of accurate peripheral information without user intervention. Recently, as an autonomous navigation system applying LIDAR has been utilized in human living space, it is necessary to solve the eye-safety problem, and to make reliable judgment through accurate obstacle recognition in various environments. In this paper, we construct a single-shot LIDAR system (SSLs) using a 1550-nm eye-safe light source, and report the analysis method and results of LIDAR signals for various measurement environments, reflective materials, and material angles. We analyze the signals of materials with different reflectance in each measurement environment by using a 5% Al reflector and a building wall located at a distance of 25 m, under indoor, daytime, and nighttime conditions. In addition, signal analysis of the angle change of the material is carried out, considering actual obstacles at various angles. This signal analysis has the merit of possibly confirming the correlation between measurement environment, reflection conditions, and LIDAR signal, by using the SNR to determine the reliability of the received information, and the timing jitter, which is an index of the accuracy of the distance information.