• Title/Summary/Keyword: jig

Search Result 683, Processing Time 0.022 seconds

The Characteristics of a Superposed Discharge Type Ozonizer with Variation of Mesh in Internal Electrode (내부전극 조밀도 변화에 따른 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.87-93
    • /
    • 2005
  • In order to develope high concentration$\cdot$yield ozonizer, superposed discharge type ozonizer using overlap of silent discharge and internal electrode of mesh type has been designed and manufactured. It consists of three electrodes(central electrode, internal electrode and external electrode) and double gaps(gap between central electrode and internal electrode, gap between internal electrode and external electrode). Therefore, ozone is generated by overlapping silent discharges generated between the gaps respectively for which the AC high voltages applied to the internal electrode and the external electrode has a $180{[^\circ]}$ phase difference and for which the central electrode is a ground Ozone generation characteristics proportional to mesh of internal electrode by increasing of discharge electrode and controlling of discharge power density. As a result, the in maximum ozone concentration, generation, and yield can be obtained 17,720[ppm], 5.4[g/h], and 205[g/kwh] respectively.

The Characteristics of Ozone Generation Synergy Effect for 3 Electrode-1 Discharge Gap Silent Discharge Type Ozonizer using Frequency-Vacuum (주파수-진공도를 이용한 3전극-1방전간극 무성방전형 오존발생기의 오존생성 상승 효과 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.94-101
    • /
    • 2005
  • The silent discharge type ozonizer with three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode) has been designed and manufactured. It is a silent discharge type ozonizer for which the AC high frequency voltages applied to the central electrode within vacuum discharge tube and the internal electrode for which the external electrode is a ground Ozone is generated by silent discharge in discharge gap. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, frequency of AC power source, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, ozone characteristics proportional to vacuum of discharge tube and frequency of AC power source. The maximum value of ozone can be obtained 7,700[ppm], 460[mg/h] and 70[g/kwh].

The Surface Energy Change of TAC Film Treated by an Atmospheric Pressure Plasma (대기압 플라즈마 처리에 의한 TAC 필름의 표면에너지 변화)

  • Lee, Chang-Ho;Jung, Do-Young;Park, Young-Jik;Song, Hyun-Jig;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.184-190
    • /
    • 2009
  • Tri-acetyl-cellulose(TAC) film surface was modified by atmospheric-pressure plasma technique to obtain the hydrophilic functional groups and improve the contact angle. TAC film was modified with N2 plasma ionized in dielectric barrier discharge(DBD) reactor under atmospheric pressure. We measured the change of the contact angle and the surface energy with respect to the plasma treatment conditions such as plasma treatment power, discharge gap and N2 gas flow rate. As the plasma treatment speed of 100[mm/sec], the plasma treatment power of 1.5[kW], discharge gap 2[mm] and the $N_2$ gas flow rate 140[LPM], the best contact angle and the highest surface energy were obtained. The degree of hydrophilization depended strongly on the plasma-treating time and discharge power.

The Design cnd Manufacture on the Trial Manufacture of an Automatic Escalator System for the Maintenance Conservative Technology Advancement of the Solar Cell and Street Light (태양집광판과 가로등의 유지보순 기술 향상을 위한 자동 승하강장치 시작품 설계 제작)

  • Lee, Jae-Yong;Byun, Chang-Soo;Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.61-69
    • /
    • 2008
  • In this paper, an automatic escalator system is manufactured for concentrate lighting efficiency and maintenance improvement technology of street light used a solar condenser. It can be linked with street light used a solar condenser, improved concentrate lighting efficiency by regulating concentrate light angle of a solar condenser. It can be remove and attach to solar condenser and street light. By developing street light used a solar condenser with an automatic escalator system, the lighting efficiency of street light and the concentrate lighting efficiency of solar condenser are High. The maintenance fee of street light significantly reduce and traffic congestion during working hours of street light is prevent.

The Emotional Sensibility Estimation System for Front-load Washer (드럼세탁기의 감성품질 측정 시스템)

  • Suh, Sang-Won;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.821-826
    • /
    • 2010
  • The door-lock switch is one of the most important part in the front-load washer. As an safety system, it keeps the door locked while the front-load washer or the dish washer is working and generating heat and spin. The door of front-load washer needs the emotionality as well as the safety because the consumers always get feels when using it. In this paper, We study about emotional factors in the door of front-load washer and analyze the difference of emotionality as the structure of the door-lock switch changed. For this, we analyze the force graph by using the software and the jig which can measure the force while the door is opened or closed.

Development of Thermocouple Sensor for Thermal Boundary Layer Measurement (온도 경계층 측정용 열전대 센서 개발)

  • Seo, Jongbeom;Han, S.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.983-990
    • /
    • 2014
  • This research focused on designing an appropriate thermocouple sensor for a thermal boundary layer with a large temperature gradient. It was designed to minimize the conduction error from a constant temperature wall in a boundary layer. A $79.9-{\mu}m$ thermocouple was chosen, and a five-axis device jig was developed to fabricate a butt-welded thermocouple, which is different from arc-welded junction thermocouples. This was used to minimize the size of the thermocouple junction. In addition to fabricating butt-welded thermocouples, a thorough calibration was conducted to decrease the internal error of a multimeter to ensure that the data from the butt-welded and regular thermocouples were almost the same. Based on this method, a butt-welded thermocouple with a small junction was found to be suitable for measuring the temperature in a thermal boundary layer with very large thermal gradients. Using this thermal boundary layer probe, the thermal boundary layers in a turbine cascade were measured, and the Nusselt numbers were obtained for the turbine endwall.

EFFECTS OF SURFACE TREATMENT AND BONDING AGENTS ON SHEAR BOND STRENGTH OF THE COMPOSITE RESION TO IPS-EMPRESS CERAMIC (IPS-Empress 도재에 대한 콤포짓트 레진의 전단결합강도)

  • Yoon, Byeung-Sik;Im, Mi-Kyung;Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.413-423
    • /
    • 1998
  • Dental ceramics exhibit excellent esthetic property, compressive strength, chemical durability, biocompatibility and translucency. This study evaluated the shear bond strength of composite resin to the new heat-pressed ceramic material (IPS-Empress System) depending on the surface treatments and bonding agents. The surface treatments were etching with 4.0% hydrofluoric acid, application of silane, and the combination of the two methods. Composite resin was bonded to ceramic with four kinds of dentin bonding agents(All-Bond 2, Heliobond, Scotch bond Multi-purpose and Tenure bonding agents). The ceramic specimen bonded with composite resin was mounted in the testing jig, and the universal testing machine(Zwick 020, Germany) was used to measure the shear bond strength with the cross head speed of 0.5 mm/min. The results obtained were as follows 1. The mean shear bond strength of the specimens of which the ceramic surface was treated with the combination of hydrofluoric acid and silane before bonding composite resin was significantly higher than those of the other surface treatment groups(p<0.05). 2. In the case of All-Bond 2 and Scotchbond Multi-purpose bonding agent group, the surface treatment methods did not influenced significantly on the shear bond(p>0.05). 3. Of the four bonding agents tested, the shear bond strength of Heliobond was significantly lower than those of other bonding agents regardless of the surface treatment methods(p<0.05). 4. The highest shear bond strength($12.55{\pm}1.92$ MPa) was obtained with Scotchbond Multipurpose preceded by the ceramic surface treatment with the combination of 4% hydrofluoric acid and silane.

  • PDF

Postoperative Contralateral Blepharoptosis in Patients with Unilateral Blepharoptosis and Negative Hering's Law Dependence Test (헤링씨 법칙 비의존성 단안성 윗눈꺼풀처짐증 환자에서 수술 후 생긴 건측의 눈꺼풀처짐증)

  • Ha, Won Ho;Lee, Yong Jig;Park, David Dae Hwan;Han, Dong Gil;Shim, Jeong Su
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.36-40
    • /
    • 2013
  • Background: Correction of unilateral blepharoptosis is unexpectedly difficult because healthy eye is often affected by Hering's law. Methods: We measured changes of marginal reflex distance (MRD1) on the unaffected eyelids between preoperative and 3-month postoperative photographs after ptosis correction. This study analyzed 134 unilateral blepharoptosis patients with ptosis correction from February 2002 to February 2011. Fifty patients among them were negative in Hering's law dependence test. From the preoperative and postoperative photographs the MRD1 of unaffected upper eyelids were measured and adjusted with the average pupil diameter of Koreans. Mean age was 34.4 and male was 30 and female was 20. Average follow-up periods were 14 months. Results: Thirteenth unaffected eyes (26%) showed decreased MRD1, and 3 patients (6%) showed decreased MRD1 value over 1.0 mm. Then 3 patients needed additional operations for correction of preoperatively unaffected but ptotic eyelids. Conclusion: There were no meaningful data statistically in the value of MRD1 in every unaffected eye of the patients and in the difference between preoperative and postoperative MRD1 of groups divided according to severity, causes, and types of operation.

Evaluation of the Effects of Feedback and Remediation after Formative Assessment in the Introduction to Clinical Medicine (임상실습 입문교육에서 형성평가 후 되먹임 및 재시험의 효과)

  • Lee, Yong Jig;Choi, Son Hwan
    • Korean Medical Education Review
    • /
    • v.18 no.1
    • /
    • pp.38-43
    • /
    • 2016
  • The authors investigated the effect of feedback and remediation after formative assessment (FRFA) by comparing the FRFA score and that of summative assessment (SA) in a course on clinical skills. In March 2015, 33 subjects underwent evaluation of their ability to perform a complex clinical skill using a real-time ready-made mobile assessment form tool, and through e-mail they were supplied with their feedback and final score (the pass group earned 2 points; the intermediate group earned 1 point; the nonpass group earned 0 points) followed by their self-reflection. The nonpass group underwent a re-test and e-mail feedback again until they passed the test, given the ease of performance. In December 2015, the 33 subjects took a 10-item SA, and one of the 10 items addressed a similar clinical skill. The difference between the first score on the FRFA and the score on the SA was evaluated statistically (p=0.05) through data analysis, variance distribution, correlation analysis, and linear regression analysis using SPSS software ver. 16. The increase from the score on the SA to that on the FRFA was statistically significant ($4.5{\pm}9.29$) in the pass group and the intermediate group, and was $29.7{\pm}11.49$ in the nonpass group of the formative evaluation (p<0.001). Using an FRFA could decrease the range in the standard deviation of the score and increase the minimum score among the subjects.

Radiosensitivity of the in vitro Cultured Young Plants for Sport Mutation Induction of Stevia rebaudiana Bert (스테비아(Stevia rebaudiana Bert)의 아조돌연변이유기를 위한 기내유식물체의 방사선감수성)

  • Yoon, Tai-Young;Kim, Ee-Youb;Hyun, Kyung-Sup;Jo, Han-Jig;Lee, Young-Il;Ju, Sun-Ah;Oh, Seung-Cheol;Kim, Dong Sub;Kang, Si-Yong;Ko, Jeong-Ae
    • Journal of Radiation Industry
    • /
    • v.4 no.4
    • /
    • pp.297-306
    • /
    • 2010
  • Due to the increasing incidence of diabetes, obesity and hypertensive, stevia has been placed great attentions as the sweetener to substitute sucrose in the world. Stevia was introduced to Korea in 1970's, but it has not been an attractive crop in that time. However, recently it has more attention for the natural food sweet additives. Because stevia have many problems for cultivation especially cultivar, seed germination, fertility, uniformity and glycoside quality, the sport mutation was attempted to in vitro plants for the improvement of some characteristics. The young in vitro plants was nursed on MS medium supplemented with $1mg\;l^{-1}\;GA_3$. Shoots of 10 cm height were irradiated with 0~200 Gy of gamma ray and the every node was separated and inoculated on MS basic medium. The lethality, number and length of shoot, numbers of node and branch were investigated for the evaluation of radiosensitivity. The optimum dose of gamma ray seemed to be around 80 Gy for the sport mutation induction in stevia. The lower node was more sensitive than higher node to radiation.