• Title/Summary/Keyword: jar-test

Search Result 154, Processing Time 0.025 seconds

Reuse of Rice-Hull and Application Technology Development in Waste Water Treatment (왕겨의 재활용 및 하수처리 활용기술 개발)

  • Shin, Ho-Sang;Ahn, Hye-Sil;Jung, Dong-Gyun
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2003.10a
    • /
    • pp.170-173
    • /
    • 2003
  • Activated Rice-Hull carbon was developed to remove ammonia compounds in water matrix. Isotherm adsorption tests of ammonia were conducted using a bottle-point technique and column test. Residual ammonia after Jar-Test or passing through the column was determined by Indophenol method, and assessed the removal efficiency for ammonia of the adsorbent. As a result, the adsorption capacity for ammonia of activated racehull carbon was very larger than that of coconut shell carbon, because the rice hull carbon had the higher BET surface area of silicate. The activated racehull carbon is under the development as adsorbent to remove ammonia in drinking water and waste water.

  • PDF

The Stomach's Communication with Its Related Acupoints, and the "Intelligent Tissue" Hypothesis

  • Kovich, Fletcher
    • Journal of Acupuncture Research
    • /
    • v.36 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Background: The intelligent tissue hypothesis holds that an organ's states (be it normal function or stressed states) are reflected in real time at its related acupuncture points (acupoints), causing physical, real-time changes in the local tissue. The experiment was devised to test this. Methods: The patient drank chilled water while the impedance at 6 stomach-related acupoints was monitored in real time (sample rate of 1 kHz). Any changes in the local tissue at the acupoints ought to be reflected in changes in the impedance. Results: The impedance at every test acupoint showed a response to the chilled water being ingested. Also, the duodenal pacesetter and the stomach's slow waves were clearly visible in the impedance pattern at all the acupoints. Conclusion: Hence, many separate details of the stomach's function were reflected at these acupoints. The duodenal features were consistent with the traditional indications for these acupoints, which are noted to be able to treat intestinal conditions. Therefore, the results were consistent with the hypothesis and also provided a possible explanation for how the use of these acupoints is able to treat intestinal conditions.

A Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent (하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구)

  • Choi, Choongho;Maeng, Sungkyu;Sim, Jaehwi;Choi, Jinho;Song, Kyungguen;Lee, Byungha;Cha, Hoyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.729-742
    • /
    • 2012
  • Recently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.

The Effects of Acupotomy Therapy on Carpal Tunnel Syndrome: A Report of 4 Cases

  • Lee, Seongjin;Cha, Eunhye;Yang, Muhak;Lee, Jongdeok;Lee, Jiyoung;Lee, Sojin;Kim, Deokho;Kim, Sungchul
    • Journal of Acupuncture Research
    • /
    • v.35 no.1
    • /
    • pp.4-10
    • /
    • 2018
  • The aim of this report was to show the effects of acupotomy in patients with carpal tunnel syndrome. Four patients were treated with acupotomy twice. Visual analogue scale (VAS), Tinel's sign, Phalen's test, Boston carpal tunnel syndrome questionnaire (BCTQ), muscular strength test, and a cross-sectional area of median nerve was measured using ultrasound before and after treatment. In all 4 cases, the VAS score, BCTQ score and cross-sectional area of median nerve, all decreased and muscular strength test score increased. Tinel's sign and the Phalen's test changed from a positive to a negative in most cases. This report shows that acupotomy is an effective treatment for carpal tunnel syndrome. Further larger are needed to fully evaluate the beneficial effects of this treatment.

The Analgesic Effect of Aconitum Sinomontanum Nakai Pharmacopuncture in Sprague-Dawley Rats

  • Lee, Jung Hee;Lee, Yun Kyu;Lee, Hyun-Jong;Kim, Jae Soo
    • Journal of Acupuncture Research
    • /
    • v.38 no.2
    • /
    • pp.140-145
    • /
    • 2021
  • Background: Aconitum sinomontanum Nakai (ASN) has been reported to have analgesic effects. In this study an animal model of pharmacopuncture using ASN (100-500 mg/kg) was examined. Methods: Sprague-Dawley (SD) rats (n = 40) were randomly assigned to ASN-Low (1 mg/mL, 1.8 mL, ASN-L), ASN-Intermediate (5 mg/mL, 1.8 mL, ASN-M), ASN-High (10 mg/mL, 1.8 mL, ASN-H), negative control (0.2 mL normal saline), and positive control (0.2 mL 0.5% lidocaine) groups. All experiments were administered to the rats' left hind leg. The analgesic response was assessed by monitoring the physical (hot plate, and von Frey test) and chemical (formalin) responses to pain. Results: All ASN pharmacopuncture groups demonstrated significant differences in pain response to the hot plate test, von Frey test, and formalin test, compared to the control group (p < 0.05). The response of the ASN-M group and ASN-H groups to the hot plate, the formalin, and the von Frey tests were significantly different, compared to the lidocaine group (p < 0.05). Conclusion: ASN pharmacopuncture had a significant analgesic effect on SD rats in response to physical and chemical models of pain.

Application of Water Treatment with Membrane in Seomjin River (섬진강 수계에서 막여과 정수처리 공정 적용성 평가)

  • Kim, Jongdoo;Park, Kyungwook;Park, Chulhwi
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.12-23
    • /
    • 2013
  • On the subject of river bed water in Seomjin river, it had accomplished the verifying experiment of membrane filtration pilot plant for evaluating the applicability of its process throughout the prediction of membrane fouling as a function of the pore size of membrane and the determination of optimum coagulant dosage. On the result of the experiment for the evaluation of the membrane fouling as a function of the pore size, a increasing rate of irreversible resistance of membrane pore size $0.1{\mu}m$ and $0.01{\mu}m$ was measured each $0.44{\times}10^{12}/m^2$ and $0.42{\times}10^{12}/m^2$, respectively. And on the result of Flux-test, it showed that the optimum coagulant dosage was measured lower than the it of the Jar-test. The result to be operated in a condition of a permeate flux $1.0{\sim}1.5m^3/m^2{\cdot}day$ without coagulation and a permeate flux $1.0{\sim}2.0m^3/m^2{\cdot}day$ with coagulation was maintained at stable trans-membrane pressure (TMP) value for 6 months up to. Therefore it showed that the stable operation without the coagulation was possible on permeate flux $1.0{\sim}1.5m^3/m^2{\cdot}day$ in the operation of membrane filtration process.

Determination of the Coagulant Injection Methods for Efficient Treatment of Industrial Wastewater (산업폐수의 효율적 처리를 위한 응집제의 주입방법 결정)

  • Park, Se-Jin;Jung, Byung-Gil
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.570-575
    • /
    • 2018
  • The various of raw wastewater inflows to the industrial wastewater treatment plants everyday. This makes it difficult to operate the coagulation and flocculation efficiently as a pretreatment process for the industrial wastewater treatment. Additionally, it causes loads on evaporation and membrane facilities which are the posttreatment and alternative processes. For this reason, this study sampled raw wastewater before and after the NaOH injection. An experiment was conducted to compare the coagulation characteristics according to the methods of coagulant injection (single injection, simultaneous injection, consecutive injection, and inverse injection) aiming at efficient treatment of industrial wastewater. The coagulation experiment was conducted using a jar tester. The TDS removal efficiency by the coagulant injection methods increased in the order of consecutive injection (2.8 %) < single injection (3.9 %) < simultaneous injection(8.1 %) < inverse injection(9.6 %); the TOC removal efficiency grew in the order of single injection (84.3 %) < inverse injection (86.2 %) < consecutive injection (88.6 %) < simultaneous injection (89.1 %); the turbidity removal efficiency grew from single injection (99.7 %) < consecutive injection (99.8 %) ${\fallingdotseq}$ inverse injection (99.8 %) < simultaneous injection (99.9 %). These results show that the simultaneous inorganic coagulant-polymer coagulant injection method was more efficient than the consecutive injection method (inorganic coagulant ${\rightarrow}$ polymer coagulant).

Optimization for Production of Phellinus linteus Mycelia with Anti-Complement Activity (항보체 활성을 갖는 Phellinus linteus 균사체 생산의 최적화)

  • Seo, Ho-Chan
    • Journal of Applied Biological Chemistry
    • /
    • v.53 no.3
    • /
    • pp.179-183
    • /
    • 2010
  • To produce the functional food materials from edible mushrooms, hot-water extracts from 70 kinds of mushroom mycelia were examined for anti-complementary activity and Phellinus linteus showed the highest activity through the complement fIxation test. The maximum production of Phellinus linteus mycelia with anti-complementary activity was observed in culture medium containing soluble starch 3.0%, peptone 0.3%, yeast extract 0.4%, $MgSO_4{\cdot}7H_2O$ 0.1%, $K_2HPO_4$ 0.2% and in the culture conditions controlled at initial pH 7.0, $30^{\circ}C$ and 150 rpm by the rotary shaker. In addition, the maximum production of mycelial dry weight was 15 mg/mL after 18 days under the optimal conditions, and anti-complementary activity was reached to 88% in 5 L-jar fermenter.

Phosphorus Removal from Municipal Wastewater Using Ti-based Coagulants (티타늄계열응집제를 이용한 하수 내 인 제거)

  • Shin, So-Yeon;Kim, Jong-Ho;Ahn, Johng-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.428-434
    • /
    • 2016
  • This study evaluated the efficacy of Ti-based coagulants on phosphorus (P) removal from municipal wastewater and compared them with Al-based coagulants. Jar test experiments were performed at various chemical doses and OH/Ti molar ratio (B value). The higher the intial phosphate ($PO_4-P$) concentration, the lower the [Ti]/[P] to reach a residual concentration below 0.2 mg P/L. Removal efficiencies of total phosphorus increased with an increased coagulant dose but decreased after the efficiencies reached their maximum value regardless of coagulant or B value. On the other hand, $PO_4-P$ removal showed an increasing trend with an increased coagulant dose, reaching the plateau value under large coagulant dose conditions for both Ti- and Al-based coagulants regardless of B value. The chemical dose of Ti-based coagulants was approximately twice higher than that of Al-based coagulants with the same P-removal efficiency. The coagulation efficiency was influenced by different B values.

Optimization of Anticoagulant Production from Phellinus linteus Mycelia (상황버섯(Phellinus linteus) 균사체로부터 항혈전 생산의 최적화)

  • Seo, Ho-Chan
    • The Korean Journal of Mycology
    • /
    • v.39 no.2
    • /
    • pp.117-121
    • /
    • 2011
  • To produce the functional food materials, 50 kinds of the mycelial extracts from edible mushroom were examined for anticoagulant activity and Phellinus linteus showed the highest activity through the activated partial thromboplastin test (aPTT). The maximum production of anticoagulant activity and the mycelial growth was observed in culture medium containing soluble starch 3.0%, peptone 0.1%, $MgSO_4{\cdot}7H_2O^{\circ}C$ 0.1%, $K_2HPO_4$ 0.1% and in the culture conditions controlled at initial pH 7.0, $30^{\circ}C$ and 150 rpm by the rotary shaker. In addition, the maximum production of mycelial dry weight was 7.5 mg/mL after 10 days under the optimal conditions, and anticoagulant activity was reached to 390 sec in 5 L-jar fermentor.