• 제목/요약/키워드: isolators

검색결과 205건 처리시간 0.029초

Passive seismic protection systems with mechanical metamaterials: A current review

  • Guevara-Corzo, Jeffrey J.;Begambre-Carrillo, Oscar J.;Garcia-Sanchez, Jesus A.;Sanchez-Acevedo, Heller G.
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.417-434
    • /
    • 2022
  • In this work, a review of mechanical metamaterials and seismic protection systems that use them is carried out, focusing on passive protection systems. During the last years, a wide variety of classical systems of seismic protection have demonstrated to be an effective and practical way of reducing the seismic vulnerability of buildings, maintaining their health and structural integrity. However, with the emergence of metamaterials, which allow obtaining uncommon mechanical properties, new procedures and devices with high performance have been developed, reducing the seismic risk through novel approaches such as: seismic shields and the redirection of seismic waves; the use of stop band gaps and the construction of buried mass resonators; the design of pentamodal base isolators. These ideas are impacting traditional areas of structural engineering such as the design and building of highly efficient base isolation systems. In this work, recent advances in new seismic protection technologies and researches that integrate mechanical metamaterials are presented. A complete bibliometric analysis was carried out to identify and classify relevant authors and works related with passive seismic protection system based on mechanical metamaterial (pSPSmMMs). Finally, possible future scenarios for study and development of seismic isolators based on mechanical metamaterials are shown, identifying the relevant topics that have not yet been explored, as well as those with the greatest potential for future application.

적층(積層)고무받침의 정적(靜的) 및 동적(動的) 특성실험(特性實驗) (Static and Dynamic Tests on Laminated Rubber Bearings)

  • 김남식;이동근
    • 대한토목학회논문집
    • /
    • 제13권2호
    • /
    • pp.85-93
    • /
    • 1993
  • 구조물의 진동을 제어하기 위하여 널리 활용되고 있는 기초분리시스템(base isolation system)는 대상구조물에 경제적이며 효율적으로 적용할 수 있는 장점을 가지고 있다. 본 연구에서는 가장 널리 쓰이고 있는 적층(積層)고무받침(laminated rubber bearing) 방식의 기초분리장치(base isolator)를 제작하여 이에 대한 정적 및 동적 특성실험을 수행하였다. 실험으로부터 얻어진 결과를 통하여 제작된 기초분리 장치의 정적 및 동적특성을 분석하였으며 실제 구조물에 대한 기초분리장치로서의 적용가능성을 고찰하였다. 최종적으로 기초분리장치에서 나타나는 비선형 힘-변위 이력곡선을 수치적으로 이상화하여 실험결과와 비교하였다.

  • PDF

플로팅 슬래브궤도용 방진재의 성능에 관한 연구 (The study for performance of isolators supported floating slab track)

  • 김진호;차효정
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.569-574
    • /
    • 2007
  • The paper presents an application of the model to a practical problem of train-induced vibrations. The aim of this study is to vertify for performance of isolators which was developed in KRRI supported floating slab track. Laboratory tests on developed isolations show that the energy dissipation, under cyclic loading of constant amplitude, can be suitably represented by a combination of a viscous and a hysteretic damping. Also, other tests for structural performance are carried out, such as elastic material test, compression test and so on. The specimen, $400{\times}400{\times}300mm$, is placed between two stiff steel plates designed to uniformly distribute the compression stress on the surface.

  • PDF

정밀 가공 장비를 위한 방진 시스템 설계 사례 (A Vibration Isolation System Design for a Vibration-sensitive Equipment)

  • 홍석인;김호상;이대희;이경돈;장한기
    • 한국소음진동공학회논문집
    • /
    • 제16권3호
    • /
    • pp.307-312
    • /
    • 2006
  • In this study a vibration isolation system with the cradle-type support was designed so as to reduce the transient vibration due to positioning motion of the moving mass on worktable as well as to achieve the desired isolation efficiency on the floor vibration. The design procedure was performed in the two steps. The first step to select appropriate isolators to meet the isolation efficiency, and the second step is to reduce the transient vibration of the worktable by adopting the cradle-type support. After the application of the selected isolators with the cradle-type support to the system it was shown that the required vibration criterion(VC-D) was easily satisfied and that the undesirable transient vibration was reduced remarkably.

Relationship between Magnetic Properties of YIG Ferrites and Intermodulation Characteristics of Microwave Isolators

  • Nukaga, Masako;Henmi, Sakae
    • The Korean Journal of Ceramics
    • /
    • 제6권3호
    • /
    • pp.300-303
    • /
    • 2000
  • The generation of the intermodulation noises in microwave isolators has been studied in relation to the characteristics of YIG ferrites designed for this application. We have investigated the influences of porosity and crystalline anisotropy related to the magnetic loss, which causes the generation of intermodulation signals. The power dependence of the intermodulation power level is stressed as the crystalline anisotropy decreases. These results are consistent with the nonlinear effects of a single normal mode before the excitation of the spin-waves. It also appears that this power level is proportional to the magnitude of dc bias magnetic field.

  • PDF

면진주파수가 원통형탱크의 구조응답에 미치는 영향 (Effects of Seismic Isolated Frequency in Structural Responses of Cylindrical Tanks)

  • 구경회;이재한;유봉
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.258-265
    • /
    • 1995
  • For design of seismic isolated system the determination of isolated frequency is very important. In this paper the effects of seismic isolated frequency for cylindrical tank are investigated using the 1940 EL Centre earthquake(NS). From the results of analysis the seismic isolated frequencies significantly depend on input acceleration and displacement components in lower frequency regions. Therefore, the seismic isolated frequency should be determined by consideration of input ground motion characteristics. For the seismic analysis the modified hysteretic hi-linear model of seismic isolators which can consider the yield load variation, shape of hysterisis loop variation and hardening effects of isolators is proposed. The analyses using the proposed model give similar displacement responses but higher maximum acceleration responses than those using the simple hysteretic hi-linear model.

  • PDF

Seismic mitigation of an existing building by connecting to a base-isolated building with visco-elastic dampers

  • Yang, Zhidong;Lam, Eddie S.S.
    • Structural Engineering and Mechanics
    • /
    • 제53권1호
    • /
    • pp.57-71
    • /
    • 2015
  • This study investigates the feasibility of retrofitting an existing building by connecting the existing building to a new building using connecting dampers. The new building is base-isolated and viscoelastic dampers are assigned as connecting dampers. Scaled models are tested under three different earthquake records using a shaking table. The existing building and the new building are 9 and 8 stories respectively. The existing building model shows more than 3% increase in damping ratio. The maximum dynamic responses and the root mean square responses of the existing building model to earthquakes are substantially reduced by at least 20% and 59% respectively. Further, numerical models are developed by conducting time-history analysis to predict the performance of the proposed seismic mitigation system. The predictions agree well with the test results. Numerical simulations are carried out to optimize the properties of connecting dampers and base isolators. It is demonstrated that more than 50% of the peak responses can be reduced by properly adjusting the properties of connecting dampers and base isolators.

면진시험구조물의 수평가진응답을 활용한 면진장치 비선형 해석모델개발 (Nonlinear Analysis Model Development of Seismic Isolator Using Horizontal Seismic Excitation Responses of Isolated Test Structure)

  • 이재한;구경희;유봉
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.157-165
    • /
    • 2002
  • The seismic excitation test results of an isolated test structure for artificial time history excitation are summarized for structural modeling of the isolated structure and isolation bearing. Based on the actual dynamic behaviors and the seismic responses of the test model, linear and bilinear models for isolators are suggested. Seismic analyses are performed and compared with those of the seismic tests. The developed bilinear model is well applicable only to large shear strain area of isolators.

  • PDF

Damage identification of isolators in base-isolated torsionally coupled buildings

  • Wang, Jer-Fu;Huang, Ming-Chih;Lin, Chi-Chang;Lin, Tzu-Kang
    • Smart Structures and Systems
    • /
    • 제11권4호
    • /
    • pp.387-410
    • /
    • 2013
  • This paper deals with the damage assessment for isolators of base-isolated building systems considering the torsion-coupling (TC) effect by establishing damage indices. The damage indices can indicate the reduction in lateral stiffness of the isolator story as explicit formulas in terms of modal parameters. In addition, the damage location, expressed in terms of the estimated damage index and eccentricities before and after damage, is also presented. Numerical analysis shows that the proposed algorithms are applicable for general base-isolated multi-story TC buildings. A procedure from the analysis of seismic response to the implementation of damage indices is demonstrated by using a numerical case. A system identification technique is employed to extract modal parameters from seismic responses of a building. Results show that the proposed indices are capable of detecting the occurrence of damage and preliminarily estimating the location of damaged isolator.

이력 감진장치를 설치한 교량의 지진에 의한 동적 거동 (Dynamic Behaviour of Bridges with Hysteric Isolator under Seismic Acceleration)

  • 임정순;조재병;안영기;이희목;홍순진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.149-156
    • /
    • 1999
  • Numerical studies were carried out to investigate the mechanical properties of competent hysteric isolators for seismic design of bridge. For dynamic analysis, bridges with isolator were simplified to a model with single degree of freedom. The initial stiffness and the yielding forces of hysteric isolators were varied. Seismic responses obtained by time history analysis show that about 4% of the weight acting as the inertia force is appropriate for the yielding force of isolator. And also better results could be achieved with the values about two times the weight per unit displacement for the initial stiffness of isolator.

  • PDF