• Title/Summary/Keyword: isolator tests

Search Result 43, Processing Time 0.029 seconds

Pyroshock Isolation Performance Test using Wiremesh Isolators (와이어메쉬 절연계의 파이로 충격 절연 성능 시험)

  • Youn, Se-Hyun;Jang, Young-Soon;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.9
    • /
    • pp.923-928
    • /
    • 2008
  • Pyrotechnic shock or pyroshock is characterized as a transient vibration phenomenon which shows large acceleration and high frequency range up to 10kHz during the operation of separation devices where explosives are used. During the flight of a launch vehicle, pyroshock is mainly generated at several events such as satellite separation, fairing separation and stage separation. In this paper, wiremesh isolators are introduced and several types of isolators are manufactured for the performance tests. For the investigation of typical characteristics of wiremesh isolators, compressive loading tests are basically performed and pyroshock tests are accomplished to confirm pyroshock isolation ability of each wiremesh isolator by using 4Kg dummy mass.

Centrifuge shaking table tests on a friction pendulum bearing isolated structure with a pile foundation in soft soil

  • Shu-Sheng, Qu;Yu, Chen;Yang, Lv
    • Earthquakes and Structures
    • /
    • v.23 no.6
    • /
    • pp.517-526
    • /
    • 2022
  • Previous studies have shown that pile-soil interactions have significant influences on the isolation efficiency of an isolated structure. However, most of the existing tests were carried out using a 1-g shaking table, which cannot reproduce the soil stresses resulting in distortion of the simulated pile-soil interactions. In this study, a centrifuge shaking table modelling of the seismic responses of a friction pendulum bearing isolated structure with a pile foundation under earthquakes were conducted. The pile foundation structure was designed and constructed with a scale factor of 1:100. Two layers of the foundation soil, i.e., the bottom layer was made of plaster and the upper layer was normal soil, were carefully prepared to meet the similitude requirement. Seismic responses, including strains, displacement, acceleration, and soil pressure were collected. The settlement of the soil, sliding of the isolator, dynamic amplification factor and bending moment of the piles were analysed to reveal the influence of the soil structure interaction on the seismic performance of the structure. It is found that the soil rotates significantly under earthquake motions and the peak rotation is about 0.021 degree under 24.0 g motions. The isolator cannot return to the initial position after the tests because of the unrecoverable deformation of the soil and the friction between the curved surface of the slider and the concave plate.

Development and Shaking Table Tests of a Base Isolator for Controling Subway Train-Induced Vibration of a Steel Building (지하철 진동에 대한 철골건물 기초진동 절연장치의 개발 및 진동대 실험)

  • Kim, Jin-Koo;Song, Young-Hoon;Kwun, Hyong-Oh;Huh, Young
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.789-796
    • /
    • 1997
  • In this study a conventional rubber mount and a new form of base isolator made of steel spring coated with natural and articial rubber were manufactured and tested on a shaking table to investigate the capacity of reducing the vertical vibration of a building induced by subway train. The model structure used in the test is a 1/4 scaled steel structure, and a white noise input and train vibration records were used to check the effectiveness of the isolators. According to the results all three types of isolators turned out to perform effectively in reducing the acceleration and the natural rubber-coated one is ranked best among the isolators. However the vertical displacement of the model is increased due to the instolation of the bearings, and the safty against the lateral load induced by earthquake ground motion should be provided to be able to apply the system to the real buildings.

  • PDF

Study for Dynamic Response of EDF System (EDF 시스템의 동적거동 특성에 관한 연구)

  • 한규승;박선규;김남식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.399-402
    • /
    • 1999
  • This study is about seismic performance of the EDF(Electricite De France) system, that is among various base isolator. We get solutions of equation of motion of this system for displacement, velocity, acceleration and compared with solutions using finite element program. And, through shaking table tests we will prove seismic performance

  • PDF

Comparisons of Isolation Performances for the SMA Mesh Washer Isolator with the Variation of Pre-compressed Displacement (초기압축변위에 따른 형상기억합금 메쉬 와셔 절연계의 절연 성능 비교)

  • Youn, Se-Hyun;Jeong, Ho-Kyeong;Han, Jae-Hung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.162-168
    • /
    • 2011
  • Launch vehicles and satellites experience severe vibration and pyroshock during the flight phase. These severe dynamic loading could result in the malfunction of electric devices which equipped in the launch vehicle and satellite. In this paper, mesh washer isolators are applied to attenuate these severe shock and vibration and isolation performances are enhanced by applying pseudoelasitic SMA wire material. Through random vibration and ground pyroshock tests, outstanding isolation performances are studied. Especially, comparison of isolation performances due to the change of pre-compressive displacement of mesh washer itself are suggested and applicablity to the adaptive vibration control are confirmed.

Full-scale Shaking Table Test of Uninterruptible Power Supply Installed in 2-stories Steel Structure (2층 철골 구조물에 설치된 무정전전원장치의 실규모 진동대 실험연구)

  • Lee, Ji-Eon;Park, Won-Il;Choi, Kyoung-Kyu;Oh, Sang-Hoon;Park, Hoon-Yang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.29-38
    • /
    • 2022
  • In this study, the shaking table tests were carried out on six types of non-structural elements installed on a full-scale two-story steel structure. The shaking table tests were performed for non-structural elements with and without seismic isolators. In this study, the seismic performance of Uninterruptible Power Supply (UPS) specimens was tested and investigated. Non-seismic details were composed of conventional channel section steel beams, and the seismic isolators were composed of high damping rubber bearing (HDRB) and wire isolator. The input acceleration time histories were artificially generated to satisfy the requirements proposed by the ICC-ES AC156 code. Based on the test results, the damage and dynamic characteristics of the UPS with the seismic isolator were investigated in terms of the natural frequency, damping ratio, acceleration time history responses, dynamic amplification factors, and relative displacements. The results from the shaking table showed that the dynamic characteristics of the UPS including the acceleration response were significantly improved when using the seismic isolator.

Prediction of Structure-Borne Noise for Floating Floor Using SEA (SEA 기법을 이용한 부유상구조의 구조기인 소음 예측)

  • Park, Hee-Jun;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.258-264
    • /
    • 2007
  • Floating floors, which are mainly used for reducing interior noise levels of railway vehicle, are known to be superior to single structure in respect to sound transmission loss and vibration reduction performances. The stiffness of isolator is one of the important design variables in floating floors. From modal tests, modal properties of underframe, top floor and isolators are derived. They are used as input parameters for predicting structure-borne noise using AUTOSEA.

  • PDF

Investigation of Micro-vibration Isolation Performance of SMA Mesh Washer Isolator for Vibration Isolation of X-band Antenna (SMA 메쉬 와셔 진동 절연기를 적용한 X-band 안테나의 미소진동 절연성능 검토)

  • Jeon, Su-Hyeon;Kwon, Sung-Choel;Kim, Dae-Kwan;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.988-995
    • /
    • 2014
  • Two axis gimbal type X-band antenna system has been widely used to effectively transmit the real time image data from the observation satellite to the ground station. The micro-vibration generated by stepping motor actuation and imperfect intermeshed gear configuration of the antenna is one of the sources to degrade the image quality. To guarantee a high quality image of high resolution observation satellite, micro-vibration isolation of X-band antenna is required. In this paper, the X-band antenna vibration isolation system using pseudoelastic SMA(Shape Memory Alloy) mesh washer has been newly suggested. The basic characteristics of the SMA mesh washer isolator proposed in this study has been measured through static load tests and its effectiveness has been demonstrated by the micro-vibration isolation test of the X-band antenna.

Multi-support excitation shaking table test of a base-isolated steel cable-stayed bridge (지진격리 강재 케이블 교량의 다지점 진동대 실험)

  • Kim, Seong-Do;Ahn, Jin-Hee;Kong, Young-Ee;Choi, Hyoung-Suk;Cheung, Jin-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.161-171
    • /
    • 2015
  • A series of tests was conducted for full-scale single-pylon asymmetric cable-stayed bridges using a system of multiple shaking tables. The 2-span bridge length was 28 m, and the pylon height was 10.2 m. 4 different base conditions were considered: the fixed condition, RB (rubber bearings), LRB (lead rubber bearings), and HDRB (high damping rubber bearings). Based on investigation of the seismic response, the accelerations and displacements in the axial direction of the isolated bridge were increased compared to non-isolated case. However, the strain of the pylon was decreased, because the major mode of the structure was changed to translation for the axial direction due to the dynamic mass. The response of the cable bridge could differ from the desired response according to the locations and characteristics of the seismic isolator. Therefore, caution is required in the design and prediction in regard to the location and behavior of the seismic isolator.

Static and Dynamic Tests on Laminated Rubber Bearings (적층(積層)고무받침의 정적(靜的) 및 동적(動的) 특성실험(特性實驗))

  • Kim, Nam Sik;Lee, Dong Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.85-93
    • /
    • 1993
  • Base isolation systems are economic and efficient for the control of structural vibration. In this study, the base isolators of LRB(laminated rubber bearing) type which have been generally used are fabricated and tested. From the static and dynamic tests, the characteristics of the base isolators, considering strain-hardening, hysteretic damping and horizontal stiffnesses, etc., are verified and particularly the feasibility as base isolation devices is discussed. Consequently, the test results are compared with the analytical ones that are derived from idealization as a bilinear model.

  • PDF