• Title/Summary/Keyword: isolation device

Search Result 299, Processing Time 0.025 seconds

Suprahilar Control of Glissonean Pedicle in the Open Anatomic Liver Resections: A Single Centre Experience

  • Aleksandar Karamarkovic;Milos Bracanovic;Bojan Jovanovic;Sanja Tomanovic Vujadinovic
    • Journal of Digestive Cancer Research
    • /
    • v.4 no.2
    • /
    • pp.113-121
    • /
    • 2016
  • Background: We evaluated technique of hepatic resections using suprahilar-extrafascial dissection of Glissonean pedicle with vascular stapling device for pedicle transection with intent to minimize operative time and blood loss. Methods: We analyzed the clinical records of 326 patients who underwent anatomic liver resection by suprahilar-extrafascial pedicle isolation with vascular stapling division technique. Results: The minor liver resections were associated with significantly shorter surgery duration (105.1±21.1 vs. 225.6±75.6) and transection time (40.1±14.5 vs. 96.3±55.2) than major hepatectomies (p<0.0001 for all). The mean blood loss was 350.8±100.5 mL in minor resection and 485.4±250.2 mL in major resection (p=0.001). The mean blood transfusion requirement was 400.8±109.5 mL for minor resections and 550.9±100.0 mL for major hepatectomy (p=0.072). There was no significant difference in morbidity and mortality between groups (p=0.980; p=0.945). Major as well as minor liver resection were oncology superior with no significant difference in the 5-year overall survival rates. Conclusion: Suprahilar-extrafascial dissection of Glissonean pedicle represents an effective and safe technique of liver resection. Presented approach allows early and easy ischemic delineation of appropriate liver territory to be removed with selective inflow vascular control. It is not time consuming and it is very useful in re-resection, as well as oncological reasonable.

  • PDF

A Study on 8 × 4 Dual-Polarized Array Antenna for X-Band Using LTCC-Based ME Dipole Antenna Structure (LTCC 기반 ME Dipole 안테나 구조를 활용한 X-Band 용 8 × 4 이중편파 배열안테나에 관한 연구)

  • Jung, Jae-Woong;Seo, Deokjin;Ryu, Jong-In
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.25-32
    • /
    • 2021
  • In this paper, the Magneto-Electric(ME) dipole array antenna with dual-polarization in the X-Band is proposed and it is implemented and measured. The proposed array antenna is composed of 32 single ME dipole antenna and a Teflon PCB. 1 × 1 ME dipole antenna is implemented dual-polarization by radiating vertical polarization and horizontal polarization from two pairs of radiators. 2-port feeding structures are realized by lamination process using LTCC. And, each port independently feeds the radiator through a Γ-shaped feeding strip with isolation between ports. The Teflon PCB used in the antenna array has a 4-layer structure, and 2-port is fed through the top and bottom layers. The λg/4 transformer is applied to the transmission line of the Teflon PCB for impedance matching of the arrayed antenna and the Teflon PCB, and the optimal parameters are obtained through simulation. The measured maximum antenna gains of port 1 was 18.2 dBi, Cross-pol was 1.0 dBi. And the measured maximum antenna gains of port 1 was 18.1 dBi, Cross-pol was 3.2 dBi.

Development of RF Stimulating Protocol for Effective Heat-Stimulus in Subcutaneous Tissue (피하에 효과적인 열 자극을 위한 고주파 자극 프로토콜 개발)

  • Myoung, Hyoun Seok;Lee, Dae Won;Kim, Han Sung;Lee, Kyoung Joung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.194-201
    • /
    • 2012
  • Moxibustion is utilized not only to cure disease but also to increase immunity. However, it may lead to undesired effects including severe pains(blisters and burns) because of the difficulty of controlling heat intensity. To overcome these problems we developed the RF heat stimulation system which can control stimulus. Also, we developed the RF stimulation protocol for effective heat transfer in subcutaneous tissue of rabbit. RF stimulator consists of a medical RF capacitive heating device, isolation probe, isolation plate, negative pressure control part and temperature measurement part. For the designed stimulus protocol, we measured the temperature distribution on epidermis and in subcutaneous(5mm, 10mm) area of rabbit during moxibustion. A stimulation protocol was designed by controlling the ON/OFF duty ratio, repeating number, and energy of applied pulse to get the temperature distribution similar with that by moxibustion. In results, the correlation coefficients between temperature distribution by moxibustion and that of stimulator were 95% and 91% from 5mm and 10mm thick respectively. However, temperature distribution on epidermis by stimulator was remarkably lower than that of the moxibustion. Finally, the RF stimulation system showed that it can not only transfer effectively heat similar with moxibustion to the subcutaneous area, but also the influence by unwanted side effects can be minimized.

Design and Fabrication of Dual Linear Polarization Stack Antenna for 4.7GHz Frequency Band (4.7 GHz 대역에서 동작하는 이중 선형편파 적층 안테나의 설계 및 제작)

  • Joong-Han Yoon;Chan-Se Yu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.2
    • /
    • pp.251-258
    • /
    • 2023
  • In this paper, we propose DLP(Dual Linear Polarization) stack antenna for private network. The proposed antenna has general stack structure and design airgap between two substrate to obtain the maximum gain. Also, to improve cross polarization isolation, two feeding port is designed to separate for each substrate. The size of each patch antenna is 17.80 mm(W1)×16.70 mm(L1) for lower patch and 18.56 mm(W2)×18.73 mm(L2) for upper patch, which is designed on the FR-4 substrate which thickness (h) is 1.6 mm, and the dielectric constant is 4.3, and which is 40.0 mm(W)×40.0 mm(L) for total size of substrate. From the fabrication and measurement results, bandwidths of 100 MHz (4.74 to 4.84 GHz) for feeding port 1, and 150 MHz (4.67 to 4.82 GHz) for feeding port 2 are obtained on the basis of -10 dB return loss and transmission coefficient S21 is got under the -20 dB. Also, cross polarization isolation between each feeding port obtained

Implementation of Gray-to-Gray 3D Crosstalk Reduction using Look-Up Table and Sub-Field Mapping (룩업 테이블 및 서브필드 맵핑을 이용한 계조 레벨 간 3D 크로스토크 저감 기술 구현)

  • Hong, Jae-Geun;Chung, Hae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.10
    • /
    • pp.928-936
    • /
    • 2013
  • 3D crosstalk is one of the disturbing things to recognize 3D images. This is caused by the phenomenon that input image for left eye is transferred at the right eye and right eye is transferred at the left eye because of the imperfect isolation by the device characteristics. In this paper, we review the 3D PDP (Plasma Display Panel) operation using active shutter glasses and crosstalk measurement method and investigate the major cause of 3D crosstalk and extend conventional 3D crosstalk using full white and full black image input to Gray-to-Gray (GtoG) 3D crosstalk. We suggest a specific method to reduce Gray-to-Gray 3D crosstalk by using Look up Table (LUT) and sub-field mapping in PDP. And then, we verify the method by measuring GtoG 3D crosstalk rate through specific test images and numerical results.

Design of Two-Step Open System for Personalized Health Data Access (개인화된 건강 데이터 처리를 위한 2-Step 개방형 시스템의 설계)

  • Jeon, Young-Jun;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.177-183
    • /
    • 2015
  • The purpose of ICT Healing platform is the prevention of chronic disease. It is intended to early warning of the disease through the information such as the bio-signals and lifestyle. In this paper, we provide a 2-Step open system(TOS) for personalized health data access. TOS is connected between the personal health related data providers and service providers of individuals ICT Healing platform, a software engine for relaying personalized health data. The proposed system, to operate in isolation to 2 step in personal health document repository Inbound module and Outbound module to provide an inquiry service to external organizations. Therefore, we propose a personalized editable Manifest concept for defining data exchange between Step. This can be used as a reference model to collect the personal health information is scattered in many health related service institutions (Hospitals, Fitness Centers, Health Examination Centers, Personal Health Device, etc.) and under private-led liberalization.

Design and Implementation of a Internal Mobile Antenna for TDMB and KPCS (TDMB와 KPCS 대역을 지원하는 내장형 휴대폰 안테나의 설계 및 구현)

  • Park, Jun-Han;Lee, Chi-Woo;Yang, Myo-Geun;Seong, Won-Mo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.2
    • /
    • pp.161-166
    • /
    • 2009
  • In this paper, we propose the internal mobile antenna for TDMB and KPCS. The proposed antenna is made of different dielectric substrate and it has small size ($45{\times}8{\times}8\;mm$, about 2.8 cc) for mobile device. TDMB antenna is designed spiral structure that makes maximum current for each cell and KPCS antenna is PIFA that is usually used for internal antenna. In order to compensate length of resonance TDMB antenna has a large inductor above 100 nH. In this case, the inductor isolate KPCS signal at TDMB by cutting high frequency. Also the antenna has good isolation because TDMB radiator is parasitic element in KPCS band. We simulated the antenna by using CST microwave studio and measured performance of the antenna in anechoic chamber Proposed antenna has $-6{\sim}-14\;dBi$ gain for TDMB and $-3.5{\sim}-5\;dBi$ gain for KPCS.

Alignment of Microbeads Using Spinning Helical Minichannel Cartridge (회전하는 나선형 미니채널 카트리지를 이용한 미세입자 정렬)

  • Kim, Subin;Prasad, Bibin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • Separation of particles based on different sizes, detection of pathogenic bacteria and isolation of leukocytes from whole blood are typical applications of spiral or helical microchannels. The present study focuses on developing a CD4+ T-cell counting device for monitoring HIV/AIDS patients with the aid of a helical minichannel used for a sample cartridge. For the experiment, $10{\mu}m$ sized microbeads were used for visualization with a fluorescence imaging system. Alignment of microbeads was investigated in a stationary and spinning sample cartridge filled with glycerol-water mixtures of different densities. The helical minichannel was spun using a DC motor controlled by an Arduino board with a Bluetooth shield. It was found that when the sample cartridge was made stationary, no bead alignment was achieved for a medium with density (0% and 20% glycerol) lower than that of the beads, but when it was spun at 2000-3000 rpm for 1-4 min, an alignment was obtained at the top of the channel facilitating optical detection and enumeration of those microbeads. Since an alignment of microbeads was achieved for a medium with density as that of blood plasma, the same approach can be applied for aligning and counting CD4+ T-lymphocytes in whole blood samples collected from patients.

Disinfection Efficiency of Medium Pressure UV Lamp on Major Bacteria in Sand Filtered Water (사여과수에 존재하는 우점세균의 중압 자외선 램프 소독능)

  • Ahn, Seoung-Koo;Yang, Yoon-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1141-1146
    • /
    • 2010
  • Isolated the heterotrophic aerobic bacteria in sandfiltered water on NA and TSBA solid medium, selected 8 dominant species and identified by Sherlock System. Each samples are irradiated 0, 5, 16, 40 and $60\;mJ/cm^2$ using on CBD (Collimated Beam Device) Medium Pressure UV lamp after these identified bacterium did liquid culture how to make $10^6{\sim}10^7\;cells/mL$ suspended in dilution water. Then cultured bacteria are estimated inactivation rate on plate media. Identified Gram positive group are Bacillus Subtilus, Bacillus megaterium, Rhodococcus erythropolis and Microbacterium laevaniformans; Gram negative group are Pseudomonas vesicularis, Pseudomonas pseudoflava, Alcaligenes paradoxus and Zooglea ramigera. These isolation of bacterium are more stronger reference strain and high resistance of MP UV irradiation, Besides Gram negative bacterium are more sensitive Gram positive bacterium on MP UV dose. Now we are estimating to $60{\sim}100\;mJ/cm^2$ MP UV dose for efficient disinfection in water treatment plant.

Numerical Study on a Reaction Wheel and Wheel-Disturbance Modeling (반작용휠 및 휠 교란 모델링에 관한 해석적 연구)

  • Kim, Dae-Kwan;Oh, Shi-Hwan;Yong, Ki-Lyuk;Yang, Koon-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.7
    • /
    • pp.702-708
    • /
    • 2010
  • Reaction wheel assemblies(RWA) are expected to be one of the largest high frequency disturbance sources to the optical payload of satellites. To ensure the tight pointing-stability budget and high image quality of satellites, a vibration isolation device should be applied to the main disturbances. For developing the isolating system, the disturbances need to be identified and modeled accurately. In the present study, a modeling technique of RWA and its disturbance was described. The micro-vibration disturbances were generated numerically by using an analytical wheel and disturbance model. The parameter estimation scheme of the model was suggested, and the RWA and disturbance modeling technique was verified through the numerical example analysis. The analytical results show that the wheel and disturbance model can be accurately established by using the modeling technique proposed in the present study. The wheel and disturbance model is expected to be useful for development of the RWA isolator system.