• Title/Summary/Keyword: isolation device

Search Result 299, Processing Time 0.029 seconds

Oxide Planarization of Trench Structure using Chemical Mechanical Polishing(CMP) (기계화학적 연마를 이용한 트렌치 구조의 산화막 평탄화)

  • 김철복;김상용;서용진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.838-843
    • /
    • 2002
  • Chemical mechanical polishing(CMP) process has been widely used to planarize dielectric layers, which can be applied to the integrated circuits for deep sub-micron technology. The reverse moat etch process has been used for the shallow trench isolation(STI)-chemical mechanical polishing(CMP) process with conventional low selectivity slurries. Thus, the process became more complex, and the defects were seriously increased. In this paper, we studied the direct STI-CMP process without reverse moat etch step using high selectivity slurry(HSS). As our experimental results show, it was possible to achieve a global planarization without the complicated reverse moat process, the STI-CMP process could be dramatically simplified, and the defect level was reduced. Therefore the throughput, yield, and stability in the ULSI semiconductor device fabrication could be greatly improved.

The Fabrication and Electrical Characteristics of Planar Multi-Quantum well (MQW) Avalanche, MQW-pn, and p-i-n Photodiode Implantd with Oxygen for Electrical Isolation (Oxygen 이온 주입의 전기적 고립을 통한 평면형 다중 양자 우물 구조의 애벌런치 & pn 및 p - i- n광 다이오드의 제작 및 전기적 특성)

  • ;;D.Sivco;D.L.Jacobsen;A.Y.cho
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.9
    • /
    • pp.43-49
    • /
    • 1997
  • The dependence of the electrical properties in planar MQW - APD & pn, and p - i - n photodiode implanted with oxygen on the annealing emperatures and ion dose has been investigated. The oxygen implantation was performed for inter-device isolation. The leakage current of as-impanted p-i-n photodiode obtained was less than 50 nA. An annelaing temperature dependence study shows an abrupt increase of leakge current at 600.deg.C for all devices under study. This indicates that donor complex centers introduced by the chemical activity of oxygen increase with increasing annelaing temperatures. Furthermore, leakage current was highly correlated with oxygen dose due to th eimplanted related defects.

  • PDF

A Study on Using Infilled Trenches for Vibration Reduction of Underground Structures by Train Loading (열차하중에 의한 지중구조물의 소음진동감소를 위한 차단벽사용에 관한 연구)

  • 권기준;정대열;고철수;김용길;황성호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.724-729
    • /
    • 2003
  • Installing vibration isolation in structures, such as structures adjacent to subways, may be delicatebecause of the proximity with the vibration source or because of the wave propagation path. This paper discusses on method that install isolation Pads on underground walls as a part of the vibration mitigation system, and also on its efficiency, The proposed method is proven to affect significantly the distribution of acceleration in the neighborhood of the structure and to reduce efficiently the maximum amplitude of the vibration. It is also seen that installing isolating pads until the depth of the foundations and deeper is more efficient than installing such device separately from the structure. This Study being limited to the comparison of installation methods, further Studies considering the thickness, stiffness and other parameters should be required.

  • PDF

Optimization of Double Polishing Pad for STI-CMP Applications (STI-CMP 적용을 위한 이중 연마 패드의 최적화)

  • Park, Seong-U;Seo, Yong-Jin;Kim, Sang-Yong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.311-315
    • /
    • 2002
  • Chemical mechanical polishing (CMP) process was required for the global planarization of inter-metal dielectric(IMD), inter-level dielectric (ILD) layers of multi-layer interconnections. In this paper, we studied the characteristics of polishing pad, which can apply shallow trench isolation (STI)-CMP process for global planarization of multi-level interconnection structure. Also, we investigated the effects of different sets of polishing pad, such as soft and hard pad. As an experimental result, hard pad showed center-fast type, and soft pad showed edge-fast type. Totally, the defect level has shown little difference, however, the counts of scratch was detected less than 2 on JR111 pad. Through the above results, we can select optimum polishing pad, so we can expect the improvements of throughput and device yield.

Effects of High Damping Rubber Bearing on Horizontal and Vertical Seismic Responses of a Pressurized Water Reactor

  • Bong Yoo;Lee, Jae-Han;Koo, Gyeong-Hoi
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.1021-1026
    • /
    • 1995
  • The seismic responses of a base isolated Pressurized Water Reactor (PWR) are investigated using a mathematical model which expresses the superstructure as lumped mass-spring model and the seismic isolator as an equivalent spring-damper. Time history analyses are performed for the 1940 E1 Centre earthquakes in both horizontal and vertical directions. In the analysis, structural damping of 5% is used for the superstructure. The isolator damping ratios of 12% for horizontal and 5% for vertical directions are used. The acceleration responses in base isolated PWR superstructure with high damping rubber bearings are much smaller than those in fixed base structure in horizontal direction. However, the vertical acceleration responses at the superstructure in the base isolation system are amplified to some extent. It is suggested that the vertical seismic responses at the superstructure should be reduced by introducing a soft vertical isolation device.

  • PDF

Serviceability Evaluation of Sky Bridge With Isolation Device (면진장치 장착 스카이 브릿지의 사용성 평가)

  • Kim, Gee-Cheol;Kim, Hyun-Su;Kim, Su-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.71-77
    • /
    • 2017
  • In this study, the boundary non-linear analysis of the sky bridge subjected to walking load and running load is performed. The sky bridge is installed in the mid-story between two buildings and the walking load and running load induced by pedestrians are measured by load cell. LRB is modeled as a non-linear hysteresis model to accurately represent the behavior of LRB. For the serviceability evaluation of sky bridge, the acceleration responses of sky bridge are analyzed based on ISO 2631-2 and the velocity response are analyzed based on standards Bachmann &Amann. In serviceability evaluation of this sky bridge, the pedestrian can not perceive the vibration except for resonance running loads consequently. Therefore, it is concluded that this sky bridge haven't problem in the serviceability.

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

The MOSFET Hump Characteristics Occurring at STI Channel Edge (STI 채널 모서리에서 발생하는 MOSFET의 험프 특성)

  • 김현호;이천희
    • Journal of the Korea Society for Simulation
    • /
    • v.11 no.1
    • /
    • pp.23-30
    • /
    • 2002
  • An STI(Shallow Trench Isolation) by using a CMP(Chemical Mechanical Polishing) process has been one of the key issues in the device isolation[1] In this paper we fabricated N, P-MOSFEET tall analyse hump characteristics in various rounding oxdation thickness(ex : Skip, 500, 800, 1000$\AA$). As a result we found that hump occurred at STI channel edge region by field oxide recess. and boron segregation(early turn on due to boron segregatiorn at channel edge). Therefore we improved that hump occurrence by increased oxidation thickness, and control field oxide recess( 20nm), wet oxidation etch time(19HF,30sec), STI nitride wet cleaning time(99HF, 60sec+P 90min) and fate pre-oxidation cleaning time (U10min+19HF, 60sec) to prevent hump occurring at STI channel edge.

  • PDF

Dynamic Response Analysis of 200m Honeycomb Lattice Domes by Rise Span Ratio (라이즈 스팬 비에 의한 200m 허니컴 래티스 돔의 동적 응답 분석)

  • Park, Kang-Geun;Chung, Mi-Ja
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.2
    • /
    • pp.51-61
    • /
    • 2019
  • The objective of this study is to analysis the seismic response of 200m spanned honeycomb lattice domes under horizontal and up-down ground motion of El Centro earthquake. For the analysis of seismic response of the honeycomb lattice domes by rise/span ratio, the time history analysis is used for the estimation of the dynamic response. The low rise lattice dome is less deformed and less stressed than the high rise lattice dome for the earthquake ground motion. The 3-dimensional earthquake response is not significantly different the dynamic response of one directional ground motion. The earthquake response of domes with LRB isolation system is significantly reduced for the asymmetric vertical deformation and the horizontal and vertical accelerations.

Characteristics of Isolator for material parameter (페라이트 소재변수에 따른 아이솔레이터 특성 연구)

  • Jun, Dong-Suk;Lee, Hong-Yeol;Kim, Dong-Young;Lee, Sang-Seak
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.119-122
    • /
    • 2003
  • This paper describes characteristics for insertion losses of Isolator have an effect on material parameter. One purpose of the paper is to present insertion loss on this resonator for magnetic loss, dielectric loss, magnetic field and saturation magnetization. Another is to study the effect of propeller resonator on response characteristics. In this paper, the analysis and measurement of the response characteristics were carried out for the isolator prototype. The measurement results agreed on the simulation results and acquire insertion loss $0.18\;{\sim}\;0.24dB$, return loss 27dB, isolation 27dB and bandwidth 500MHz on this condition saturation magnetization 550G, dielectric loss 0.0004, magnetic loss 20 and dielectric constant 14.

  • PDF