• Title/Summary/Keyword: iso-beam

Search Result 61, Processing Time 0.032 seconds

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

Prediction of response of reinforced concrete frames exposed to fire

  • Balaji, Aneesha;Muhamed Luquman, K.;Nagarajanb, Praveen;Pillai, T.M. Madhavan
    • Advances in Computational Design
    • /
    • v.1 no.1
    • /
    • pp.105-117
    • /
    • 2016
  • The objective of this work is to study the restraining effect in fire resistance of framed structures and to evaluate the global response of reinforced concrete frames when exposed to fire based on advanced finite element method. To study the response a single portal frame is analyzed. The effect of floor slab on this frame is studied by modeling a beam-column-slab assembly. The evolution of temperature distribution, internal stresses and deformations of the frame subjected to ISO 834 standard fire curve for both the frames are studied. The thermal and structural responses are evaluated and a comparison of results of individual members and entire structure is done. From the study it can be seen that restraining forces has significant influence on both stresses and deflection and overall response of the structure when compared to individual structural member. Among the various structural elements, columns are the critical members in fire and failure of column causes the failure of entire structure. The fire rating of various structural elements of the frame is determined by various failure criteria and is compared with IS456 2000 tabulated fire rating.

STEP-Based CAE/CAO Information Exchange (STEP을 이용한 CAE/CAO 정보교환)

  • Baek, Ju-Hwan;Min, Seung-Jae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1234-1239
    • /
    • 2003
  • In the product design process computer-aided engineering and optimization tools are widely utilized in order to reduce the total development time and cost. Since several simulation tools are involved in the process, information losses, omissions, or errors are common and the importance of seamless information exchange among the tools has been increased. In this study ISO STEP standards are adopted to represent the neutral format for CAE/CAO information exchange. The schema of AP209 is used to define the information of finite element analysis and the new schema is proposed to describe the information of structural optimization based on the STEP methodology. The schema is implemented by EXPRESS, information modeling language, and ST-Developer is employed to generate C++ classes and STEP Rose Library by using the schema denoted. To substantiate the proposed approach, the information access interfaces of the finite element modeling software (FEMAP), structural optimization software (GENESIS) and in-house topology optimization program are developed. Examples of the size optimization of a three-bar truss and topology optimization of a MBB beam are shown to validate the information exchange of finite element analysis and structural optimization using STEP standards.

  • PDF

Effect of Trifunctional Monomers and Antioxidants on the Crosslinking Reaction of Polyethylene (폴리에틸렌의 가교반응에 미치는 삼관능성 단위체와 산화장지제의 영향)

  • Hyung Chick Pyun;Young Chul Lee;Kil Jeong Kim;Byung Mok Yoon
    • Nuclear Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.70-77
    • /
    • 1982
  • The crosslinking reaction and oxidative stability of low-density polyethylene were studied in the presence of trifunctional monomers and antioxidants with electron beam. The trifunctional monomers used in this study are Trimethylolpropane triacrylate(TMPTA), Trimethylolpropane trimethacrylate(TMPTM) and Triallyl cyanurate(TAC). And the antioxidants are Irganox 1010 (Pentaerythritoltetrakis[3-(3,5-di-t-butyl-4-hydroxyphenyl)-propionatel]), Santo-nox R(4,4'-Thio-bis(3-methyl-6-t-butylphenol)), Nocrac D(N-phenyl-$\beta$-naphthylamine) and Bis-phenol A(4,4'-Isopropylidene bisphenol). Among the monomers, TMPTA is the best crosslinking agent and prvides polyethylene with oxidative stability. Among the antioxidants, Nocrac D is the best antioxidant for polyethylene.

  • PDF

Experimental studies on the behaviour of headed shear studs for composite beams in fire

  • Lim, Ohk Kun;Choi, Sengkwan;Kang, Sungwook;Kwon, Minjae;Choi, J. Yoon
    • Steel and Composite Structures
    • /
    • v.32 no.6
    • /
    • pp.743-752
    • /
    • 2019
  • Steel and concrete composite structures are commonly applied in multi-story buildings as they maximise the material strength through composite action. Despite the popularity of employing a trapezoidal deck slab, limited experimental data are available under elevated temperatures. The behaviour of the headed shear stud embedded in a transverse trapezoidal deck and solid slab was investigated at both ambient and fire conditions. Twelve push-out tests were conducted according to the ISO 834 standard fire utilising a customised electric furnace. A stud shearing failure was observed in the solid slab specimen, whereas the failure mode was changed from a concrete-dominated failure to the stud shearing in the transverse deck specimen with an increase in temperature. Comparisons between the experimental observations and design requirements are presented. The Eurocode design guidance on the transverse deck slab gives a highly conservative estimate for shear resistance. A new design formula was proposed to determine the capacity of the shear connection regardless of the slab type when the stud shearing occurs at high temperatures.

Development of Shaft Analysis Model for Power Transmission System Optimization (동력전달 시스템의 최적화를 위한 축 해석 모델 개발)

  • Lee, Ju-Yeon;Kim, Su-Chul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.5
    • /
    • pp.8-16
    • /
    • 2021
  • This study develops a shaft analysis model for the optimization of the power transmission system. The finite element method was used for the shaft analysis model. The shaft and gear were assumed Timoshenko beams. Strength was evaluated according to DIN 743, and gear misalignment was calculated through ISO 6336 and the coordinate system rotation. The analysis software for a power transmission system was developed using Visual Studio 2019. The analysis results of the developed program were compared with those of commercial software (MASTA, KISSsoft, and Romax). We confirmed that the force, deformation, and safety factors at each node were the same as those of the commercial software. The absolute value of the gear misalignment of the developed program and commercial software was different. However, the gear misalignment tended to increase with increasing the displacement in the tooth width direction.

Evaluation of Characteristics in the Reference Gamma Radiation Fields for testing of Personnel Dosimetry Performance (개인선량 평가의 성능검증을 위한 기준급 감마선장의 특성 평가)

  • Oh, Jang-Jin;Cho, Dae-Hyung;Han, Seung-Jae;Na, Seong-Ho;Lee, Dew-Hey;Lee, Byung-Soo;Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 1998
  • In order to establish a testing system for personnel dosimetry performance, the radiation fields from photons, beta particles and neutrons are required, in recent, Korea Institute of Nuclear Safety(KINS) established the reference radation fields except neutrons and tested a variety of their properties. As a result of the test, the reference beams were shown to meet satisfactorily not only the standards of the International Organization for Standardization(ISO), but also the standard levels of the developed countries which are intercomparable with the international traceability. This paper describes the reference beam of gamma radiation. The self-designed and established reference radiation fields were investigated and analyzed by ISO and other international standards. The secondary photon contribution and the beam uniformity of the gamma radiation field were measured and evaluated to fulfill those requirements suggested by the ISO-4037. The measured air kerma rate for the $^{137}$Cs and $^{60}$Co gamma fields was 0.1891 $\sim$ 23.4967 $\mu$Gy/s sand 0.5844 $\sim$ 15.9954 $\mu$Gy/s respectively. The uncertainty with 95 % confidence level of the measured air kerma rate was determined to be less than 2.5 % which is comparable to the international reference gamma radiation fields. It was found that the evaluated air kerma calibration factors of Exradin ionization chamber were in good agreement within 0.9 % and 0.03 % with those given by PTB and NIST, respectively. The gamma radiation fields installed at KINS can maintain traceability systems in Korea, Germany and United State.

  • PDF

A Study of the Adjustment and Treatment Depending on the Change of Prostate Location Using DIPS in Proton Beam Therapy for Prostate Gland in which a Fiducial Gold Marker was Inserted (Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 Digital Image Positioning System (DIPS)을 이용한 전립선의 위치변화에 따른 보정에 관한 연구)

  • Park, June-Ki;Kim, Sun-Young;Kim, Tae-Yoon;Choi, Kye-Sook;Yeom, Doo-Suk;Kang, Dong-Yoon;Choi, Seung-O;Park, Ji-Youn
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.25-29
    • /
    • 2008
  • Purpose: To monitor the changes of location of prostate gland using DIPS and to examine the adjustment and proton beam therapy depending on the movement of prostate gland in proton beam therapy for prostate gland in which a fiducial gold marker was inserted. Materials and Methods: This study was conducted in ten patients with prostate cancer who received proton beam therapy since April of 2008. To monitor the change of prostate location, three fiducial gold markers were inserted prior to the treatment. To minimize the movement of prostate gland, patients were recommended to urinate prior to the treatment, to intake a certain amount of water and to concomitantly undergo rectal balloon. In these patients, the set-up position was identical to that for a CT-simulation. The PA (posterior-anterior) and lateral images were obtained using both DIPS (digital image positioning system) and a plain radiography, and they were compared between the two imaging modalities. Thus, the changes of the location of fiducial gold marker were assessed based on three coordinates (x, y, z) and then adjusted. This was followed by proton beam therapy. Results: Images which were taken using a plain radiography were compared with those which were taken using DIPS. In ten patients, according to a reference bony marker, the mean changes of the location of fiducial gold marker based on an iso-center were X-axis: $\pm$0.116 cm, Y-axis: $\pm$0.19 cm and Z-axis: $\pm$0.176 cm. These ten patients showed a difference in the changes of location of prostate gland and it ranged between RT: 0.04 cm and RT: 0.24 cm on the X-axis; between Inf: 0.03 cm and Sup: 0.42 cm on the Y-axis; and Post: 0.05 cm and Ant: 0.35 cm on the Z-axis. Conclusion: To minimize the movement of prostate gland, as the pre-treatment prior to the treatment. In all the patients, however, three fiducial gold markers showed a daily variation which were inserted in the prostate gland. Based on the above data, Thus, the requirement of gold marker matching system depending on the daily variation in the proton beam therapy for which more accurate establishment of target was confirmed. It is assumed that an accurate effect of proton beam therapy would be enhanced by adjusting the target-center depending on the location change of prostate gland using DIPS which was used in the current study.

  • PDF

Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations (전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, Jong-Hak;Lee, Ki-Yeol;Kim, Hyung-Cheol;Kim, Jang-Seob;Shin, Dong-Chul;Lee, Sung-Hyun;Lee, Jun-Hyub;Shin, Gwi-Soon
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.453-460
    • /
    • 2009
  • The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of $2{\times}0.5\;mm$, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

  • PDF

Lower the Detection Limits of Accelerator Mass Spectrometry

  • John A., Eliades;Song, Jong-Han;Kim, Jun-Gon;Kim, Jae-Yeol;O, Jong-Ju;Kim, Jong-Chan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.243-244
    • /
    • 2013
  • Over the past 15 years, several groups have incorporated radio-frequency quadrupole (RFQ) based instruments before the accelerator in accelerator mass spectrometry (AMS) systems for ion-gas interactions at low kinetic energy (<40 eV). Most AMS systems arebased on a tandem accelerator, which requires negative ions at injection. Typically, AMS sensitivity abundance ratios for radioactive-to-stable isotope are limited to Xr/Xs >10^-15, and the range of isotopes that can be analyzed is limited because of theneed to produce rather large negative ion beams and the presence of atomic isobaric interferences after stripping. The potential of using low-kinetic energy ion-gas interactions for isobar suppression before the accelerator has been demonstrated for several negative ion isobar systems with a prototype RFQ system incorporated into the AMS system at IsoTrace Laboratory, Canada (Ontario, Toronto). Requisite for any such RFQ system applied to very rare isotope analysis is large transmission of the analyte ion. This requires proper phase-space matching between the RFQ acceptance and the ion beam phase space (e.g. 35 keV, ${\varphi}3mm$, +-35 mrad), and the ability to control the average ion energy during interactions with the gas. A segmented RFQ instrument is currently being designed at Korea Institute for Science and Technology (한국과학기술연구원, KIST). It will consist of: a) an initial static voltage electrode deceleration region, to lower the ion energy from 35 keV down to <40 eV at injection into the first RFQ segment; b) the segmented quadrupole ion-gas interaction region; c) a static voltage electrode re-acceleration region for ion injection into a tandem accelerator. Design considerations and modeling will be discussed. This system should greatly lower the detection limits of the 6 MV AMS system currently being commissioned at KIST. As an example, current detection sensitivity of 41Ca/Ca is limited to the order of 10^-15 while the 41Ca/Ca abundance in modern samples is typically 41Ca/Ca~10^-14 - 10^-15. The major atomic isobaric interference in AMS is 41K. Proof-of-principal work at IsoTrace Lab. has demonstrated that a properly designed system can achieve a relative suppression of KF3-/41CaF3- >4 orders of magnitude while maintaining very high transmission of the 41CaF3- ion. This would lower the 41Ca detection limits of the KIST AMS system to at least 41Ca/Ca~10^-19. As Ca is found in bones and shells, this would potentially allow direct dating of valuable anthropological archives and archives relevant to our understanding of the most pronounced climate change events over the past million years that cannot be directly dated with the presently accessible isotopes.

  • PDF