• Title/Summary/Keyword: ion-electrode

Search Result 1,164, Processing Time 0.025 seconds

Electrochemical Properties of Sub-micron Size Si Anode Materials Distributed by Wet Sedimentation Method (습식 분급으로 입도 조절된 서브 마이크론 크기의 Si 음극활물질의 전기화학적 특성 분석)

  • Jin-Seong Seo;Hyun-Su Kim;Byung-Ki Na
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.39-44
    • /
    • 2023
  • In this study, the particle size of Si polycrystals was controlled through wet-sedimentation method, and changes in the capacity and cyclic characteristics of the Si anode material according to the particle size were observed. After wet-sedimentation of Si particles pulverized by a vibration mill, the non-uniform particle distribution of Si was uniformly controlled. The d50 of a sample in which Si was sedimented for 24 hours decreased to 0.50 ㎛. As a result of the electrochemical characteristic analysis, the Rct value representing the resistance in the electrode was significantly reduced due to the decrease in particle size. The unclassified Si sample exhibited a discharge capacity of 2,869 mAh/g in the first cycle, and decreased to 85.7 mAh/g after 100 cycles. The sample in which Si was classified for 24 hours showed a capacity of 3,394 mAh/g initially, and maintained a capacity of 1,726 mAh/g after 100 cycles. As the size of the Si particles decreased, the discharge capacity increased and the cycle life was also increased.

Comparison of Sampling Methods for On-Farm Use Quick Test Procedure of Soil Nitrate (토양의 질산태질소 현장검정을 위한 시료 채취방법 비교)

  • Kang, Seong-Soo;Kim, Ki-In;Chung, Keun-Yook;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.1
    • /
    • pp.32-37
    • /
    • 2005
  • The procedure of soil sampling for on-farm quick test of soil nitrate is very important to improve practical application without weighing or drying soil. To improve application of test strip reflectometer as a quick on-farm analytical procedure for the estimation of soil nitrate concentration, three sampling methods such as gravimetric sampling (GS), particle density sampling (PDS) and bulk density sampling (BDS) for on-farm analytical procedure were investigated with twelve soils of 45 to $281mg\;kg^{-1}$ nitrate nitrogen concentration. The nitrate nitrogen concentrations measured from different soils were compared with two analytical methods, ion electrode method as a standard laboratory analysis (SLA) and test strip reflectometer at three moisture conditions, viz. air dried soil, 20 and 40% of maximum water holding capacity (MWHC). Nitrate nitrogen concentration measured by test strip reflectometer was significantly correlated with that of SLA, and the coefficients of variation (CV) were in the range of 3.5 to 10.9%. These CV values less than 10.9% were thought to be acceptable for the measurement of soil nitrate as an on-farm real time analytical procedure. The nitrate nitrogen concentration by BDS for test strip reflectometer as well as ion electrode method was more similar to that of SLA compared with those by GS and PDS especially in case of moist soils. This result suggests that the BDS is more useful than GS and PDS in case of on-farm analytical procedure of soil nitrate for moist soils. Further the practical measurement by BDS could be improved by substituting the bottle cap with a larger container.

Assessment Techniques of Heavy Metal Bioavailability in Soil - A critical Review (토양 중 중금속 생물유효도 평가방법 - 총설)

  • Kim, Kwon-Rae;Owens, Gary;Naidu, Ravi;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.4
    • /
    • pp.311-325
    • /
    • 2007
  • The concept of metal bioavailability, rather than total metal in soils, is increasingly becoming important for a thorough understanding of risk assessment and remediation. This is because bioavailable metals generally represented by the labile or soluble metal components existing as either free ions or soluble complexed ions are likely to be accessible to receptor organismsrather than heavy metals tightly bound on soil surface. Consequently, many researchers have investigated the bioavailability of metals in both soil and solution phases together with the key soil properties influencing bioavailability. In order to study bioavailability changes various techniques have been developed including chemical based extraction (weak salt solution extraction, chelate extraction, etc.) and speciation of metals using devices such as ion selective electrode (ISE) and diffusive gradient in the thin film (DGT). Changes in soil metal bioavailability typically occur through adsorption/desorption reactions of metal ions exchanged between soil solution and soil binding sites in response to changes in environment factors such as soil pH, organic matter (OM), dissolved organic carbon (DOC), low-molecular weight organic acids (LMWOAs), and index cations. Increasesin soil pH result in decreases in metal bioavailability through adsorption of metal ions on deprotonated binding sites. Organic matter may also decrease metal bioavailability by providing more negatively charged binding sites, and metal bioavailability can also be decreases as concentrations of DOC and LMWOAs increase as these both form strong chelate complexeswith metal ions in soil solution. The interaction of metal ions with these soil properties also varies depending on the soil and metal type.

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

The Structural and Electrochemical Properties of Li[Ni0.6-xBaxCo0.1Mn0.3]O2 (x = 0, 0.01) by Barium Doping (Barium 도핑에 따른 Li[Ni0.6-xBaxCo0.1Mn0.3]O2(x=0, 0.01) 의 구조 분석 및 전기화학적 특성)

  • Jang, Byeong-Chan;Yoo, Gi-Won;Yang, Su-Bin;Min, Song-Gi;Son, Jong-Tae
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.4
    • /
    • pp.222-228
    • /
    • 2014
  • Ni-rich system $Li[Ni_{1-x-y}Co_xMn_y]O_2$ of lithium secondary battery cathode material keep a high discharge capacity. However, by the Ni content increases, there is a problem that the electrochemical properties and stability of the structure are reduced. In order to solve these problems, research for positive ion doping is performed. The one of the cathode material, barium-doped $Li[Ni_{0.6-x}Ba_xCo_{0.1}Mn_{0.3}]O_2$ (x=0.01), was synthesized by the precursor, $Ni_{0.6}Co_{0.1}Mn_{0.3}(OH)_2$, from the co-precipitation method. The barium doped materials have studied the structural and electrochemical properties. The analysis of structural properties, results of X-ray diffraction analysis, and those results confirmed the change of the lattice from the binding energy in the structure by barium doping. Increased stability of the layered structure was observed by $I_{(006)}+I_{(102)}/I_{(101)}$(R-factor) ratio decrease. we expected that the electrochemical characteristics are improved. 23 mAh/g discharge capacity of barium-doped $Li[Ni_{0.6-x}Ba_xCo_{0.1}Mn_{0.3}]O_2$ (x=0.01) electrode is higher than discharge capacity of $Li[Ni_{0.6}Co_{0.1}Mn_{0.3}]O_2$ due to decrease overvoltage. And, through the structural stability was confirmed that improved the cycle characteristics. We caused a reduction in charge transfer resistance between the electrolyte and the electrode was confirmed that the C-rate characteristics are improved.

Electrochemical Performance as the Positive Electrode of Polyaniline and Polypyrrole Hollow Sphere with Different Shell Thickness (껍질 두께가 다른 폴리아닐린과 폴리피롤 속 빈 구형체 양전극의 전기화학적 성능)

  • Yun, Su-Ryeon;Hwang, Seung-Gi;Cho, Sung-Woo;Kang, Yongku;Ryu, Kawng-Sun
    • Applied Chemistry for Engineering
    • /
    • v.23 no.2
    • /
    • pp.131-137
    • /
    • 2012
  • Polyaniline (PANI) and polypyrrole (Ppy) hollow sphere structures with controlled shell thicknesses can be easily synthesized than those of using a layer-by-layer method for cathode active material of lithium-ion batteries. Polystyrene (PS) core was synthesized by emulsion polymerization using an anion surfactant. The shell thicknesses of PANI and Ppy were controlled by amounts of aniline and pyrrole monomers. PS was removed by an organic solution. This structure increased in contact with an electrolyte and a specific capacity in lithium-ion batteries. But polymers have disadvantages such as the difficult control of molecular weights and low densities. These disadvantages were completed by controlled shell thicknesses. The amount of aniline monomer increased from 1.2, 2.4, 3.6, 4.8 to 6.0 mL, and the shell thicknesses were 30.2, 38.0, 42.2, 48.2, and 52.4 nm, respectively. And the amount of pyrrole monomer was 0.6, 1.2, 2.4 and 3.6 mL, the shell thicknesses were 16.0, 22.0, 27.0 and 34.0 nm, respectively. In the cathode materials with controlled shell thicknesses, shell thicknesses of the PANI hollow spheres were 30.2, 42.2, and 52.4 nm, and discharge specific capacities of after 10 cycle were ~18, ~29, and ~62 mAh/g, respectively. The shell thicknesses of the Ppy hollow spheres were 16.0, 22.0, 27.0 and 34.0 nm, and discharge specific capacities of after 15 cycle were ~15, ~36, ~56, and ~77 mAh/g, respectively. Thus, shell thicknesses of PANI and Ppy increased, the specific capacities increased.

Development of Energy Harvesting Hybrid system consisted of Electrochromic Device and Dye-Sensitized Solar Cell using Nano Particle Deposition System (나노 입자 적층 시스템(NPDS)을 이용한 염료 감응 태양전지 - 전기 변색 통합 소자 및 에너지 하베스팅 시스템에 대한 연구)

  • Kim, Kwangmin;Kim, Hyungsub;Choi, Dahyun;Lee, Minji;Park, Yunchan;Chu, Wonshik;Chun, Dooman;Lee, Caroline Sunyong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.2
    • /
    • pp.65-71
    • /
    • 2016
  • In this study, Antimony Tin Oxide (ATO) ion storage layer and $TiO_2$ working electrode were fabricated using Nano Particle Deposition System. NPDS is the cutting-edge technology among the dry deposition methods. Accelerated particles are deposited on the substrate through the nozzle using NPDS. The thicknesses for coated layers were measured and layer's morphology was acquired using SEM. The fabricated electrochromic cell's transmittance was measured using UV-Visible spectrometer and power source at 630 nm. As a result, the integrated electrochromic/DSSC hybrid system was successfully fabricated as an energy harvesting system. The fabricated electrochromic cell was self-operated using DSSC as a power source. In conclusion, the electrochromic cell was operated for 500 cycles, with 49% of maximum transmittance change. Also the photovoltaic efficiency for DSSC was measured to be 2.55% while the electrochromic cell on the integrated system had resulted in 26% of maximum transmittance change.

Fabrication of Hydrogel and Gas Permeable Membranes for FET Type Dissolved $CO_{2}$ Sensor by Photolithographic Method (사진식각법을 이용한 FET형 용존 $CO_{2}$ 센서의 수화젤막 및 가스 투과막 제작)

  • Park, Lee-Soon;Kim, Sang-Tae;Koh, Kwang-Nak
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.207-213
    • /
    • 1997
  • A field effect transistor(FET) type dissolved carbon dioxide($pCO_{2}$) sensor with a double layer structure of hydrogel membrane and $CO_{2}$ gas permeable membrane was fabricated by utilizing a $H^{+}$ ion selective field effect transistor(pH-ISFET) with Ag/AgCl reference electrode as a base chip. Formation of hydrogel membrane with photo-crosslinkable PVA-SbQ or PVP-PVAc/photosensitizer system was not suitable with the photolithographic process. Furthermore, hydrogel membrane on pH-ISFET base chip could be fabricated by photolithographic method with the aid of N,N,N',N'-tetramethyl othylenediarnine(TED) as $O_{2}$ quencher without using polyester film as a $O_{2}$ blanket during UV irradiation process. Photosensitive urethane acrylate type oligomer was used as gas permeable membrane on top of hydrogel layer. The FET type $pCO_{2}$ sensor fabricated by photolithographic method showed good linearity (linear calibration curve) in the range of $10^{-3}{\sim}10^{0}\;mol/{\ell}$ of dissolved $CO_{2}$ in aqueous solution with high sensitivity.

  • PDF

Preparation of Solid Polymer Electrolytes by Ultraviolet Radiation and the Electrochemical Properties of Activated Carbon Supercapacitor Adopting Them (자외선 조사에 의한 고체 고분자 전해질의 제조와 이를 채용한 활성탄 수퍼커패시터의 전기화학적 특성)

  • Won, Jung Ha;Kim, Yong Joo;Lee, Young-Gi;Kim, Kwang Man;Kim, Jong Huy;Ko, Jang Myoun
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.2
    • /
    • pp.91-97
    • /
    • 2013
  • Solid polymer electrolyte films are prepared by ultraviolet radiation in the mixtures of an ionic liquid salt (1-ethyl-3-methylimidazolium tetrafluoroborate, $EMIBF_4$) and solvent (acetonitrile (ACN) or propylene carbonate(PC)), and an oligomer (poly(ethylene glycol)diacrylate, PEGDA, 45-60 wt.%). Electrochemical properties of activated carbon supercapacitors adopting the solid polymer electrolyte films as a separator are also examined by cyclic voltammetry and impedance measurement techniques. As a result, the supercapacitor adopting the PEGDA as much as 45 wt.% exhibits a superior capacitance of $46Fg^{-1}$ at $20mVs^{-1}$. It seems that this is due to fast kinetics of ion conduction by sufficient film flexibility, which can be allowed by comparatively weak ultraviolet curing of small anount of the PEGDA.

Separation of Soybean Protein by Free-flow Electrophoresis (자유유동 전기이동법에 의한 대두단백질 분리)

  • 한재갑;류화원
    • KSBB Journal
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 1995
  • The effect of operating conditions on separation of soybean proteins in a home-made free-flow electrophoresis apparatus was investigated. Measurement of the pH, conductivity, and UV-absorbance(280 nm) were carried out at each run and the purity of the sample was tested with SDS-PAGE analysis. The soybean extract pretreated with Tris and boric acid was mixed with the amino acids composed of glutamic acid, histidine, arginine, glycine(1 mM each) with glycyl-glycine(2mM) and KCl(1mM). When the cellulose acetate was used as a compartment between the electrode and the buffer solution in the cell, pH distribution in the separation cell varied from 3.0 at the anodic side to 8.0 at the cathodic side and had two inflection point. The applied voltage was from 300V to 1000V and the separation was better at a higher voltage but the voltage was limited by the capability of the cooling system due to Joule heat. The proteins focused near the middle of the channel. From the change of pH and conductivity it was found that the ions in the channel moved out to the electrodes through the membrane. In the case when the concentration of the buffer solution was increased 5 times, proteins were focused at 300V. We could not increase up to the ten times of the concentration since the temperature difference between inlet and outlet was more than $25^{\circ}C$ and denaturation of proteins was expected. When ion-exchange membranes were used U-type pH distribution was set up due to the ionic polarization near the membrane. The commercial ampholytes, instead of the mixed amino acids showed not much improvements in purity of the separated sample.

  • PDF