• Title/Summary/Keyword: ion probe

Search Result 280, Processing Time 0.023 seconds

Friction and Pull-off Forces on Submicron-Size Asperity Measured in High Vacuum

  • Ando, Y.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.57-58
    • /
    • 2002
  • Asperity arrays and Independent asperities were fabricated on a silicon plate. Then pull-off and friction forces were measured on each asperity pattern by using AFM (atomic force microscope) in humid air and high vacuum of $2{\times}10^{-5}$ Pa. The probe of AFM cantilever has a flat square of about $1\;{\mu}m^2$ on its tip. The results showed that the pull-off force was proportional to the curvature radius of asperity peak in each ambient condition. The friction force was proportional to the pull-off force and was slightly higher in the humid air than in the high vacuum.

  • PDF

Simple Ratiometric Fluorophore for the Selective Detection of Mercury through Hg(II)-Mediated Oxazole Formation

  • Lee, Hee-Jin;Kim, Hae-Jo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.3959-3962
    • /
    • 2011
  • A simple propargylamide-fuctionalized chemodosimeter was prepared for the ratiometric fluorescence detection of mercuric ions in HEPES buffer. The chemodosimeter exhibited $Hg^{2+}$-induced propargyl amide-tooxazole transformation, with a significant accompanying ratiometric change in fluorescence. It afforded high selectivity for mercuric ion detection without any competitive inhibition by common alkali, alkaline earth, or other transition metal ions. The probe showed a $17{\times}10^{-6}M$ detection limit for $Hg^{2+}$ ions and potential applicability for detecting aqueous $Hg^{2+}$ ions.

"Turn-on" type colorimetric/fluorimetric probe for selective detection of Cu2+ at neutral pH condition

  • Lee, Hyun Jung;Saleem, Muhammad;Lee, Ki Hwan
    • Rapid Communication in Photoscience
    • /
    • v.4 no.4
    • /
    • pp.88-90
    • /
    • 2015
  • The design and development of fluorescent chemosensors have recently been intensively explored for sensitive and specific detection of environmentally and biologically relevant metal ions in aqueous solution and living cells. Herein, we report the photophysical results of rhodamine B based fluorogenic and chromogenic receptor for selective copper detection in the complete organic or mixed aqueous-organic media at neutral pH under ambient condition. The ligand exhibited the remarkable increment in the fluorescence emission and UV-visible absorption signal intensities at 587 and 547 nm, respectively, on induction of copper ion while the ligand solution remain completely silent on addition of varieties of other metal ions.

Light Effects on the Membrane Potential in Oat Cells

  • Kim, Kwan-Bae;Park, Moon-Hwan;Chae, Quae
    • BMB Reports
    • /
    • v.28 no.5
    • /
    • pp.382-386
    • /
    • 1995
  • One of the reaction pathways in light-invoked signal transduction can be initiated through ion fluxes across the plasma membrane in higher plants. We isolated protoplasts from oat coleoptile and examined the effects of light on the membrane potential using a membrane potential-sensitive fluorescent probe (bisoxonol). Both red and far-red light initially induced a hyperpolarization in oat cells. Red light-induced hyperpolarization was effectively dissipated by 100 mM $K^+$, but the hyperpolarization induced by far-red light was not depolarized by any of the cations ($K^+$, $Ca^{2+}$, $Li^+$, $Na^+$) tested. The depolarization induced by red light and $K^+$ was inhibited by 200 mM TEA, which is a $K^+$ channel blocker. These results suggest that $K^+$ influx through the inward $K^+$ channel may be a depolarization path in the phytochrome-mediated signal transduction.

  • PDF

Study of Self Texturing on ZnO:Al TCO surface for Thin-Film Solar Cell (박막태양전지용 ZnO:Al 투명전도막 표면 Self-Texturing 연구)

  • Oh, Kyoung Suk;Yoon, Soon Gil;Lee, Jeong Chul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.127.2-127.2
    • /
    • 2011
  • 본 연구에서는 RF Magnetron Sputtering System을 이용하여 ZnO계 투명전도막 증착시 Vaporization된 MeOH를 유입함으로써 박막증착과 동시에 표면의 Roughness를 제어하여 이에따른 전기적 특성 및 광학적 특성의 개선에 대하여 연구하였다. 실험방법으로 기존의 RF Magnetron Sputtering System에 Vaporization이 가능한 Ultrasonic을 이용하여 MeOH를 Vaporized시켜 MFC Controll을 통해 챔버에 유입하여 ZnO계 투명전도막의 박막증착과 동시에 표면 Texturing을 하였다. ZnO계 투명전도막의 박막증착시 Vaporized MeOH의 유입에 따른 광학적 특성변화를 UV-visible-nIR spectrometry로 조사하였으며, 전기적 특성 변화를 4-Point-Probe로 조사하였으며, 표면적 특성 변화를 Atomic Force Microscope(AFM), Scanning Electron Microscopy(SEM)를 조사하였으며, 박막의 결정성장특성 변화를 X-ray Diffraction(XRD)으로 조사하였으며, Vaporized MeOH 유입에 따른 박막의 성분분석을 Secondary Ion Mass Spectrometry (SIMS)로 조사함으로써 최적의 조건 및 공정을 확립하였다.

  • PDF

Analysis of Electrical Property on Inductively Coupled Ar Plasma for Gas Pressure (유도결합형 Ar 플라즈마의 압력에 따른 전기적 특성분석)

  • 조주웅;이영환;김광수;허인성;최용성;박대희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.133-136
    • /
    • 2004
  • Low-Pressure inductively coupled RF discharge sources have important industrial applications mainly because they can provide a high-density electrodeless plasma source with low ion energy and low power loss. In an inductive discharge, the RF power is coupled to the plasma by an electromagnetic interaction with the current flowing in a coil. In this paper, the experiments have been focussed on the electric characteristic and carried out using a single Langmuir probe. The internal electric characteristics of inductively coupled Ar RF discharge at 13.56(MHz) have been measured over a wide range of power at gas pressure ranging from 1∼70(mTorr).

The Electrical Characteristic of Composite Film for Lithium Secondary Battery by adding DMSO (DMSO 첨가에 따른 리튬이차전지용 복합필름의 전기적 특성)

  • 박수길;김종진;이창진;김상욱;김현후;임기조;이주성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.269-272
    • /
    • 1997
  • The Lithium ion secondary battery has been developed for high energy density of portable electrical device and electronics. Among the many conductive polymer materials, the positive active film for Li polymer battery system was synthesized successfully from polyphenylene diamine(PPD) by chemical polymerization in our lab. And PPD-DMcT(2, 5-dimercapto-1, 3, 4-thi-adiazole) composite flim conductive material, at high temperature was also prerared with the addition of dimethylsulfoxide(DMSO). The surface morphology and thermal stability of prepared composite flim was carried out by using SEM and TGA, respectively. Electrochemical and electrical conductivity of composite flim were also discussed by cyclic voltammetry and four-probe method in dry box(<27pm). And the electrode reaction mechanism was detected and analyzed from the half cell unit battery system.

  • PDF

Magnetization Frequency Dependence of Enhanced Inductively Coupled Plasma and Etching Characteristics (자화주파수에 따른 플라즈마 및 산화막식각특성에 관한 연구)

  • 김진우;조수범;박세근;오범환
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.37-40
    • /
    • 2001
  • The semiconductor's design rule becomes more stringent, hence the silicon-dioxide etching technique is important issue. In this work we compared the etching characteristics of different three types of Plasma source, Normal ICP, magnetized ICP and E-IC $P^{TM}$. The E-IC $P^{TM}$ source shows higher etch rate at lower pressure and this is advantageous for the fine pattern process. The etching characteristics were varied with external magnetic field frequency at I-lCP and this is examined with Nanospe $c^{TM}$ and SEM. We designed Langmuir probe system for time resolved diagnosis. ion density of E-ICP is varying periodically with the applied external magnetic field frequencyquency

  • PDF

In-Line Hologram for Plasma Diagnostics

  • Kim, Byungwhan;Jung, Jin-Su
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.524-529
    • /
    • 2016
  • Diagnostic sensors are demanded during plasma processes. Holograms of plasma taken with laser light without a reference beam were used to monitor behaviors of charged particles produced in nitrogen plasma as a function of electrode temperature ranging between 50 and 300℃. Holograms were characterized as a function of the pixel sum and grayscale value. Pixel sum calculated in identified grayscale ranges strongly correlated with ion density and emitted light intensity measured with a langmuir probe and optical emission spectroscopy, respectively. The performance was further evaluated with data acquired as a function of N2 and NH3 flow rates and improved correlations were observed in the new grayscale range. The confirmed correlations indicate that a hologram is a viable means to diagnose behaviors of plasma particles such as ions. Underlying principles are discussed in view of particle and charge composing vacuum and light.

Vertical Transport of Protons in Amorphous Ice

  • Moon, Eui-Seong;Kim, Young-Soon;Shin, Sung-Hwan;Kang, Heon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.279-279
    • /
    • 2012
  • In order to estimate the average migration lengths of $H_3O^+$ ions in amorphous ice, we conducted experiments of reactive ion scattering (RIS), low energy sputtering (LES), and reflection absorption IR spectroscopy (RAIRS) with an ultra-high vacuum (UHV) chamber. Dopped water-ice films were grown on the clean surface of Ru single crystal and analyzed with RIS, LES and RAIRS methods. The population changes of probe molecules, which were buried at a controlled distance from the surface, were monitored by those methods so that we can mesure the migration efficiencies. From the measured efficiencies, we evaluated the average migration lengths. This result is expected to give the information about the dynamics of proton in water-ice film.

  • PDF