• 제목/요약/키워드: ion chromatograph

검색결과 70건 처리시간 0.028초

Ion Chromatography에 의한 음료수중 음이온 함량에 관한 연구 (Measurement of an Ion Concentration in Drinking Water by lon Chromatography)

  • 김형석
    • 환경위생공학
    • /
    • 제4권1호
    • /
    • pp.7-15
    • /
    • 1989
  • According to the increase of population and development of industrialization air and water pollution problems are still keeping going to great nuisance to human activities. Specially man should drink 2l clean water to maintain our health every day, but we afraid of drink the city tap water because of the contaminants like heavy metals, bacteria trihalomethane, etc. In the analysis of the anions in potable water, we usually adapt the Standard methods for the Examination of Water and Wastewater. But this method is tedious and time consuming, so the Ion Chromatography method is now used in research of water quality. Author worked with Ion Chromatography in measuring the anions in drinking water by attaching conductivity dector to normal High Performance Liquid Chromatograph. Low-capacity ion-exchange coulmn and dilute eluents, 0.00M phthalic aic was used in this study. The concentration of chloride ion was 1.55 ppm$\~$3 8.81ppm, nitrate ion was 5.45 ppm$\~$18.27ppm, and sulfate ion was 19.64 ppm$\~$28.86 ppm. The phosphate ion was detected only in Apt. tap water as 167.99 ppm whose amount was supposed to be used as a water pipe cleaner.

  • PDF

이온크로마토그래피를 활용한 무기산류 정도관리 방법 연구 (A Study on Quality Control of Inorganic Acids using Ion Chromatograph)

  • 박해동;박승현;정기효
    • 한국산업보건학회지
    • /
    • 제31권1호
    • /
    • pp.22-30
    • /
    • 2021
  • Objectives: The objectives of this study were to develop a quality control protocol of inorganic acids using ion chromatograph and to evaluate analytical proficiency of the legally designated agencies. Methods: This study prepared inorganic acid samples by injecting three anion certified solutions (chloride, nitrate, and sulfate) on the quartz filters. To investigate the storage stability and concentration consistency of the samples, 240 samples for each anion were tested at weeks 0, 2, 4, 8, 12, and 16 while storing at 4℃ and 25℃. To evaluate analytical proficiency, two separate testings were administrated for six skilled analysts and 46 analysts affiliated with legally designated agencies. Results: Average recoveries of the three ions after 16 weeks of storage were fairly high (over 95%). In addition, average recoveries (chloride = 97%, nitrate = 96%, and sulfate = 103%) after 16 weeks of storage at low temperate were relatively higher than those (94%, 93%, and 98%) at room temperature. The coefficients of variation (CV) for the three ions were less than 5% except for the sulfate sample at 5.56 ㎍ (CV = 12.4%). The average ratios of the concentration values analyzed by the legally designated agencies to the injected concentrations were close to 1. However, their CVs were relatively greater (chloride ≤ 49%, nitrate ≤ 14%, and sulfate ≤ 28%), which implies a need for quality control. Conclusions: The quality control protocol used in this study for the three inorganic acids can be utilized in the quality control for ion chromatography.

단이론에 따른 단백질 이온교환 크로마토그라피의 연구 (A Study of Protein Ion Exchange Chromatography based on Plate Theory)

  • 김인호;김진태
    • 한국미생물·생명공학회지
    • /
    • 제23권4호
    • /
    • pp.485-491
    • /
    • 1995
  • Protein ion exchange chromatography was studied experimentally in order to prove the theoretical prediction from the linear model of Yamamoto, S. et al (1). Adsorption isotherms were measured as a function of ionic strength in a batch experiment. The relationship between the characteristics of chromatogram and the operating conditions of ionic strength, flow rate, length of column, concentration and amount of protein sample were studied. At the higher ionic strength, the lower flow rate and the longer column conditions, the higher number of plate was obtained. Satisfactory agreement was observed between the experimental and the calculated chromatograms except for the case of high protein concentration.

  • PDF

Direct Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry

  • Nam, Sang-Ho;Kim, Jae-Jin;Han, Soung-Sim
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권12호
    • /
    • pp.1805-1808
    • /
    • 2003
  • The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method. The IC-ICP-MS technique was applied for the determination of arsenic species in a NIST SRM 1643d water sample. An As(III) only was detected in the sample. The detection limits of As(III), As(V) and DMA were 0.31, 0.45, and 2.09 ng/mL, respectively. It was also applied for the determination of arsenic species in a human urine obtained by a volunteer, and three arsenic species were identified. The determination of total As in human urines that were obtained from 25 volunteers at the different age was also carried out by ICP-MS.

이온 크로마토그래피를 이용한 충전전압에 따른 $LiCoO_2$ 전극의 표면 특성 (Electrode Surface Analysis of Delithiated $LiCoO_2$ using Ion Chromatograph)

  • 김동훈;신혜민;정영동;;도칠훈;진봉수;문성인;김현수;오대희;김기원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.498-499
    • /
    • 2007
  • In this paper, we report on a study of the electrode/electrolyte interfaces of MCMB/$LiCoO_2$ cell using Ion-chromatography. The cells for the experiments were preconditioned by cycling three times and stabilized at OCV of 3.0V 4.35V and 4.5V. The stabilized cathode electrode was used for surface characterization investigations. Concerning the $LiCoO_2$/electrolyte interfaces, the result obtained have shown the presence of $F^-\;and\;CO_3^{2-}$ on the surface of cathode electrode as well as increasing the concentration of ions as cell voltage increase.

  • PDF

공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도- (Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures)

  • 신용철;이병규;이지태
    • 한국대기환경학회지
    • /
    • 제18권1호
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

Capillary Zone Electrophoresis를 이용한 음이온 동시분석에 관한 연구 (Analysis of Inorganic Acids by Capillary Zone Electrophoresis)

  • 박성우;진광호;유재훈;김동환;서배석;김영상
    • 분석과학
    • /
    • 제11권3호
    • /
    • pp.213-221
    • /
    • 1998
  • Bromide, chloride, fluoride, nitrite, nitrate, sulfite, sulfate, perchlorate, chlorate 및 chlorite가 포함된 시료를 capillary zone electrophoresis(CZE)와 indirect UV detection 방법으로 분리하였다. 음이온류의 분리는 running buffer로 5 mM ammonium dichromate, 10 mM ammonium acetate, 20 mM diethylenetriamine, 10% methanol(pH 9.3)을 사용하였으며 전압은 cathode에 15 kV를 공급하였다. 또한 최초로 CZE에서 음이온의 정량이 가능하도록 각 이온들에 대한 regression과 detection limit를 결정하였고, 이 분석방법은 톨루엔을 흡입한 사람의 뇨, 부검 혈액, 폐수 및 폭약 등 시료에 적용하였으며, 음이온의 함량을 ion chromatograph(IC)와 비교 검토하였다.

  • PDF

자외선에너지(UV-C)를 이용한 유기인계 화합물의 분해 (Decomposition of Organophosphorous Compounds with Ultraviolet Energy(UV-C))

  • 김종향;민병철
    • 공업화학
    • /
    • 제9권1호
    • /
    • pp.28-32
    • /
    • 1998
  • 두 종류의 유기인계 살충제인 디클로로보스와 클로로피리포스를 UV조사, UV 조사와 $TiO_2$분말 그리고 UV조사와 sea sand를 저압수은 램프를 이용하여 분해실험을 하였다. 이 화합물의 확인은 가스크로마토그래프, 총유기탄소 그리고 이온크로마토그래프를 사용하였다. 두 물질 모두, UV조사와 sea sand가 UV 조사와 UV조사와 $TiO_2$분말보다 분해가 더 잘 되었다. 반응 최종생성물은 디클로르보스에서는 $Cl^-$, 클로로피리포스에서는 $Cl^-$ $SO_4{^{2-}}$등이 생성되었다.

  • PDF

호흡기 침착부위에 따른 미세먼지 중 수용성 이온성분의 일별 농도 측정 (Daily Concentration Measurements of Water-soluble Inorganic Ions in the Atmospheric Fine Particulate for Respiratory Deposition Region)

  • 강공언;이상복
    • 한국환경보건학회지
    • /
    • 제31권5호
    • /
    • pp.387-397
    • /
    • 2005
  • In oder to understand the deposition possibility of water-soluble inorganic ions in the atmospheric fine particulates for the human respiratory tract, the mass size distribution of ion species was measured using an Anderson sampler in the Iksan during fall, 2004. Samples were analyzed for major water-soluble ions using Dionex DX-100 ion chromatograph. The size distribution of water-soluble inorganic ions in the atmospheric particulates appeared bimodal distribution, which were divided around $1-2{\mu}m$ into two groups. Mass site distribution of total ion in the coarse mode was found to be almost similar level during the sampling period, but fluctuations of mass size distribution in the fine mode were observed. Considering the mass size distribution of total ion concentrations for the respiratory deposition region, it was found that about 77.1% of total tons could be deposited in the alveolar region, and which dominated the daily variation of total ion concentrations. The concentration of total ions, which could be deposited in both the head region and the tracheobronchial region, was $3.95{\mu}g/m^3$, whereas that in the alveolar rerion was $13.28{\mu}g/m^3$. Dominant ions which could be deposited in the alveolar region were ${NO_3}{^-},\;{SO_4}^{2-}\;and\;{NH_4{^+}$, accounting for about 40%, 27% and 22% of the total ions, respectively. Although $K^+$ was approximately 3% of total ions, it was shown that most of this could be deposited in the alveolar region due to its high fraction of small size distribution originated from anthropogenic source of biomass burning. The presence of these ions in the fine mode may be of public health significance as they are very biologically harmful to health and have a high probability of being deposited in human lung tissue.

열수송관에 연결된 에어벤트에 적용 가능한 부식 방지 방안 (Corrosion Protective Method Applicable to Air Vent Connected with a Heat Transport Pipe)

  • 송민지;최가현;김우철;이수열
    • Corrosion Science and Technology
    • /
    • 제22권2호
    • /
    • pp.115-122
    • /
    • 2023
  • This study aimed to elucidate causes of corrosion of heat transport pipes and air vents installed under a manhole of heat transport facilities and suggest effective anticorrosive measures by applying paints or adhesive tapes. It was found that air vent corrosion was attributed to corrosion under insulation caused by the inflow of water and the enrichment of chloride ions. The infiltrated water caused a hydrolysis of polyurethane foam (PUF) insulation by concentrating chloride ions at the interface between a pipe and the PUF. As insulator deteriorated, more chloride ions were eluted as confirmed by ion chromatograph (IC) analysis. As an effective method to prevent air vent corrosion, different types of paints and adhesive tapes with higher corrosion resistance on chloride ions were applied and environmental resistance tests were performed with those samples. Based on environmental test results of samples exposed to 10% HCl solution, it was revealed that a wax tape was the most adequate from a viewpoint of stability at operating condition, environmental resistance, surface treatment, and field applicability.