• Title/Summary/Keyword: ion beam modification

Search Result 84, Processing Time 0.031 seconds

Development of Inductively Coupled Plasma Gas Ion Source for Focused Ion Beam (유도결합형 플라즈마 소스를 이용한 집속 이온빔용 가스 이온원 개발)

  • Lee, Seung-Hun;Kim, Do-Geun;Kang, Jae-Wook;Kim, Tae-Gon;Min, Byung-Kwon;Kim, Jong-Kuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.1
    • /
    • pp.19-23
    • /
    • 2011
  • Recently, focused ion beam (FIB) applications have been investigated for the modification of VLSI circuit, the MEMS processing, and the localized ion doping, A multi aperture FIB system has been introduced as the demands of FIB applications for high speed and large area processing increase. A liquid metal ion source has problems, a large angular divergence and a metal contamination into a substrate. In this study, a gas ion source was introduced to replace a liquid metal ion source. The gas ion source generated inductively coupled plasma (ICP) in a quartz tube (diameter: 45 mm). Ar gas fed into the quartz was ionized by a 2 turned radio frequency antenna. The Ar ions were extracted by 2 extraction grids. The maximum extraction voltage was 10 kV. A numerical simulation was used to optimize the design of extraction grids and to predict an ion trajectory. As a result, the maximum ion current density was 38 $mA/cm^2$ and the spread of ion energy was 1.6 % for the extraction voltage.

INVESTIGATION OF MULTI-ARC PLASMA PLATING FILM EQUIPMENT BULAT-6 AND ITS TECHNICAL CHARACTERISTICS

  • Wen Xueya;Ma Te2ngcai;Hu Shejun
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.133-136
    • /
    • 1997
  • In this paper multi-arc plasma plating film equipment Bulat-6 and its technical characteristics were analyzed in detail. This machine is the first of its kind in China. Influential factors and reducing methods on microdroplets of titanium were investigated. By method of electromagnetic field control and ion beam enhanced deposition excellent titanium nitride film could be obtained. Bicrohardness and adhesion were 250Mpa and 6.5Kg respectively.

  • PDF

Surface Modification of Polytetrafluoroethylene by Using Low Energy Hydrogen Ion Beam (저에너지 수소 이온빔을 이용한 polytetrafluoroethylene 표면 개질)

  • Lee, Jung-Hwan;Kim, Dong-Hwan;Yeo, Woon-Jung;Han, Young-Gun;Cho, Jun-Sik;Kim, Hyun-Joo;Koh, Seok-Jeun
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.612-618
    • /
    • 2006
  • Surface modification of PTFE by ion irradiation was performed to improve its surface properties, In the case where argon was used to irradiate the PTFE films, an increase in the adhesion strength was observed when the ion fluence was over $1\times10^{15}\;ions/cm^2$, but the surface morphology dramatically changed to a needle-shaped one. However, when we used hydrogen ions under $O_2$ environmental gas, the adhesion strength increased at an ion fluence of $5\times10^{16}\;ions/cm^2$ and the surface morphology by the hydrogen irradiation was not needle-shaped. The surface morphology and adhesion strength of the hydrogen modified PTFE was influenced by the oxygen flow rate. It was confirmed by reflectance measurements that the surface properties of the hydrogen ion irradiated PTFE were superior to those of the argon ion irradiated PTFE.

Surface Modification of Polytetrafluoroethylene by 1 keV Argon and Hydrogen Irradiated in Nitrogen and Ammonia Gas Environment (질소와 암모니아 존재하에서 1 keV 에너지의 알곤과 수소 이온 조사에 의한 PTFE(polytetrafluoroethylene)의 표면형상 변화연구)

  • Yeu, Dae-Hwan;Kim, Ki-Hwan;Kang, Dong-Yeob;Kim, Joong-Soo;Koh, Seok-Keun;Kim, Hyun-Joo
    • Korean Journal of Materials Research
    • /
    • v.16 no.6
    • /
    • pp.367-372
    • /
    • 2006
  • Polytetrafluoroethylene (PTFE) surface was modified for improving hydrophilicity by ion irradiation in environmental gas of $N_2$ and $NH_3$, respectively. The water contact angle onto the PTFE surface increased from $104{\circ}$ to over $140{\circ}$ by Ar ion irradiation in $N_2$ gas. In the case of $NH_3$ as environmental gas, there were a slight increase of contact angle from ion dose of $1{\times}10^{15}\;to\;5{\times}10^{15}\;ions/cm^2$, and its dramatic decrease to the value of 35o at the conditions of ion dose higher than $1{\times}10^{16}\;ions/cm^2$. It was found from SEM results that the surface morphology of PTFE was changed into one with filament structure after Ar ion irradiation in $N_2$ gas environments. On the contrary, Ar ion irradiation in $NH_3$ gas condition induced the PTFE surface with network structure. Hydrogen ion irradiation resulted in a little change of PTFE surface morphology, comparing with the case of Ar ion irradiation. The water contact angle of hydrogen ion irradiated PTFE surface in reactive gas decreased with increment of ion dose. Hydrogen ion irradiation could improve hydrophilicity with little change of surface morphology. It might be considered from FT-IR results that the improvement in wettability of PTFE surface by ion irradiation in $N_2$ and $NH_3$ gases could be due to the hydrophilic groups of NHx bonds.

KIST 정전형가속기-현황 및 활용계획

  • Kim, Jun-Gon;Song, Jong-Han;Yu, Byeong-Yong;Lee, Gyeong-Hui;Jo, Hye-Mi;Lee, Gwan-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.245-246
    • /
    • 2013
  • 한국과학기술연구원에서는 2007년부터 시작된 중대형가속기구축사업을 통하여 3기의 정전형 가속기를 설치하였다. 1996년에 도입된 2.0 MV Pelletron을 비롯하여 신규 도입된 6 MVTandetron과 400 kV implanter 등 모두 3기의 정전형가속기로 30 keV부터 ~60 MeV까지의 단색 이온빔을 인출, 이용할 수 있는 실험설비의 구축이 완성되었다. 정전형가속기의 주요 활용분야는 femto~atto mole정도의 동위원소를 측정하는 가속기질량분석법(AMS)를 비롯하여 RBS/ERD로 대표되는 이온빔분석법(ion beam analysis, IBA) 그리고 고에너지 이온빔을 이용한 물질 개질분야(ion beam material modification, IBMM)로 크게 분류된다. 이 시설은 당 연구원의 연구 수요 뿐 아니라 국내 연구자의 수요를 아우르는 시설로 계획하고 있다. 여타 실험/분석장비와 달리 가속기시설은본체의 완성 후 활용목적에 맞춰 빔라인의 증설이 필요하며 최근 가장활용성이 큰 가속기질량분석(accelerator mass spectrometry, AMS)의 경우는 활용분야별 시료 전처리 시설과 기술의 개발이 요구된다. 따라서 KIST에서는 향후 수년간 활용 분야별 대표적인 주제를 선정하고 필요한 선행연구를 통하여 KIST 이온빔시설에 대한 연구자들의 접근편의성을 제고하고자한다. 본 발표에서는 지난 6년간의 수행된 가속기 시설의 개요와 함께 장차 수행할 선행연구의 방향과 내용을 소개한다(Figure capture). Layout of the newly constructed KIST ion beam facility.

  • PDF

Vacuum Web-coater with High Speed Surface Modification Equipment for fabrication of 300 mm wide Flexible Copper Clad Laminate (FCCL) (초고속 대면적 표면 처리 장치가 부착된 300 mm 폭 연성 동박적층 필림 제작용 진공 웹 코터)

  • Choi, H.W.;Park, D.H.;Kim, J.H.;Choi, W.K.;Sohn, Y.J.;Song, B.S.;Cho, J.;Kim, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2007
  • Prototype of $800{\ell}$ vacuum web coater (Vic Mama) consisting of ion source with low energy less than 250 eV for high speed surface modification and 4 magnetron sputter cathodes was designed and constructed. Its performance was evaluated through fabricating the adhesiveless flexible copper clad laminate (FCCL). Pumping speed was monitored in both upper noncoating zone pumped down by 2 turbo pumps with 2000 l/sec pumping speed and lower surface modification and sputter zone vacuumed by turbo pumps with 450 1/sec and 1300 1/sec pumping speed respectively. Ion current density, plasma density, and uniformity of ion beam current were measured using Faraday cup and the distribution of magnetic field and erosion efficiency of sputter target were also investigated. With the irradiation of ion beams on polyimide (Kapton-E, $38{\mu}m$) at different fluences, the change of wetting angle of the deionized water to polyimide surface and those of surface chemical bonding were analyzed by wetting anglometer and x-ray photoelectron spectroscopy. After investigating the deposition rate of Ni-Cr tie layer and Cu layer was investigated with the variations of roll speed and input power to sputter cathode. FCCL fabricated by sputter and electrodeposition method and characterized in terms of the peel strength, thermal and chemical stability.

Optical Reactivity Modification of Titanium Oxide coatings on Ceramic filters by Nitrogen ion Implantation

  • Kim, Hyeong-Jin;Park, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.90-90
    • /
    • 2010
  • We investigated the modification of optical response properties of titanium dioxide (TiO2) coatings on the ceramic water-purification filters by using ultraviolet-visible absorption spectroscopy and X-ray diffraction. The TiO2 coatings were prepared on ceramic substrate by e-beam evaporation method. These amorphous TiO2 were turned into anatase phase by heat treatment at $700^{\circ}C$ for 2 hours. The doping of N atoms into the TiO2 coatings was done by using 70KeV of N+ ion implantation with the dose of $1.0{\times}1017$ ions/cm2, followed by post-irradiation heat treatment at $550^{\circ}C$ for 2 hours. Methylene blue test of TiO2 coatings to solar irradiation showed that the post-evaporation heated TiO2 was photocatalytic and N-doped TiO2 reacted to the visible part of solar irradiation.

  • PDF

The improvement of Cu metal film adhesion on polymer substrate by the low-power High-frequency ion thruster

  • Jung Cho;Elena Kralkina;Yoon, Ki-Hyun;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.60-60
    • /
    • 2000
  • The adhesion interface formation between copper and poly(ethylene terephthalate)(PET), poly(methyl methacrylate)(PMMA) and Polyimide films was treated using Ion assisted reaction system to sequential sputter deposition by High-Frequency ion source. The ion beam modification system used a new type of low power HF ion thruster for space application as new low thruster electric propulsion system. Low power HF ion thruster with diameter 100mm gives the opportunity to obtain beams of Ar+ with currents 20~150 mA (current density 0.5~3.5 mA/cm2) and energy 200~2500eV at HF power level 10~150 W. Using Ar as a working gas it is possible to obtain thrust within 3~8 mN. Contact angles for untreated films were over 95$^{\circ}$ and 80 for Pet, 10o for PMMA and 12o for PI samples as a condition of ion assisted reaction at the ion dose of 10$\times$1016 ions/cm2, the ion beam potential of 1.2 keV and 4 ml/min for environmental gas flow rate. 900o peel tests yielded values of 15 to 35 for PET, 18 to 40 and 12 to 36 g/min. respectively. High resolution X-ray photoelectron spectrocopy is the Cls region for Cu metal on these polymer substrates showed increases in C=O-O groups for polymide, whereas PET and PMMA treated samples showed only C=O groups with increase the ion dose. Finally, unstable polymer surface can be changed from hydrophobic to hydrophilic formation such as C-O and C=O that were confirmed by the XPS analysis, conclusionally, the ion assisted reaction is very effective tools to attach reactive ion species to form functional groups on C-C bond chains of PET, PMMA and PI.

  • PDF

Solid Lubrication Characteristics of DLC Coated Alumina Seals in High Temperature

  • Ok, Chul-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.356-356
    • /
    • 2007
  • Plasma immersion ion beam deposition (PIIBD) technique is a cost-effective process for the deposition of diamond like carbon thin film, the possible solid lubricant on large surface and a complex shape. We used PIIB process for the preparation of DLC thin film on $Al_2O_3$ with deposition conditions of deposition temperature range $200^{\circ}C$, working gas pressure of 1.310-1Pa. DLC thin films were coated by $C_2H_2$ ion beam deposition on $Al_2O_3$ after the ion bombardment of SiH4 as the bonding layer. Energetic bombardment of $C_2H_2$ ions during the DLC deposition to ceramic materials generated mixed layers at the DLC-Si interface which enhanced the interface to be highly bonded. Wear test showed that the low coefficient of friction of around 0.05 with normal load 2.9N and proved the advantage of the low energy ion bombardment in PIIBD process which improved the tribological properties of DLC thin film coated alumina ceramic. Furthermore, PIIBD was recognized as a useful surface modification technique for the deposition of DLC thin film on the irregular shape components, such as molds, and for the improvement of wear and adhesion problems of the DLC thin film, high temperature solid lubricant.

  • PDF

CRYSTAL TRANSITION PROCESS DURING POST-BREAKDOWN IN THE MOLTEN SALT

  • Han, S.H.;Thompson, G.E.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.440-443
    • /
    • 1999
  • The morphology and composition of anodic films, formed on aluminium at various current densities, in the range 1-$100{\;}Am^{-2}$, in the molten bisulphate melt at different temperatures (418-498K), have been studied using transmission electron microscopy of ultramicrotomed film sections, and ion beam thinned films. From the structural analysis of the electron diffraction patterns taken from the ultramicrotomed sections and ion beam thinned films, it can be concluded that the crystal modification process from ${\gamma}-Al_2O_3{\;}to{\;}{\alpha}-Al_2O_3$ proceeds in the following steps : (equation omitted)

  • PDF