• Title/Summary/Keyword: inverter-type inverter

Search Result 849, Processing Time 0.022 seconds

High-Reliability Three-Phase Dual-Buck Grid-Connected Inverter without Shoot-Through Problem

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.454-462
    • /
    • 2019
  • When compared to traditional bridge-type inverters, the dual-buck inverter has a higher reliability due to the fact that its bridge legs do not have a shoot-through problem. In this paper, the working principle of the dual-buck inverter is analyzed. A comparison of the working modes under full-cycle and half-cycle control is discussed. With half-cycle control, the inverter can realize a higher efficiency. However, this results in current zero-crossing distortion. The corresponding control strategy of the dual-buck inverter is proposed in order to realize both high efficiency and low current harmonic distortion. In addition, the system stability is analyzed. Dead-time is unnecessary due to the advantages of the topology. Thus, the current harmonic distortion can be further reduced. An inverter with the proposed control strategy has the advantages of high reliability, high efficiency and low current harmonic distortion. Finally, simulation and experimental results are given to verify the theoretical analysis.

Application of Motor Drive System Using Resonant Voltage-Type Inverter (공진형 전압형 인버터의 전동기구동 시스템 응용)

  • Kim, Yong-Joo;Ma, Young-Ho;Kim, Han-Sung;Che, Geou-Ha;Kim, Byung-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.164-166
    • /
    • 1991
  • This paper achieved by Pulse-Withed Modulation of the inverter switchs. But Conventional PWM inverter is employed hard switching by means a switching device. Moreover, this paper presents resonant DC link Voltage type inverter thet it was not necessary snubber circuit and dead time and modeling of motor drive control system and simulating analysis are discussed.

  • PDF

Analysis of Characteristic for LCC Resonant type High Frequency Inverter. (LCC 공진형 고주파 인버터의 특성해석)

  • Bae, Sang-June;Kim, Jong-Hae;Lee, Bong-Seop;Kim, Kyung-Sik;O, Seung-Hune;Min, Byung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.495-497
    • /
    • 1996
  • This paper proposes LCC type high frequency resonant inverter to be used as a source of induction heating device or ultrasonic device and considers of operating characteristic for it. The inverter is operated safely over wide range load, because it has both panel loaded capacitor and series loaded capacitor. Then, switching frequency of the inverter is controlled by feedback voltage and current in order to have constant output power even when load is varied.

  • PDF

An influence on Characteristics of double resonant type high frequency inverter according to the variable capatance of the DC voltage source separated capacitor (직류 전원 분할용 커패시터의 용량변화가 복공진형 고주파 인버터의 특성에 미치는 영향)

  • 박홍일
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.360-363
    • /
    • 2000
  • A half bridge type double resonant high frequency resonant inverter using PFM is described. This proposed inverter can reduce distribution of the switching current because of using the current of the serial resonant circuit to the input current of the parallel one. In the case of variable capacitance of the DC voltage source separated capacitor the analysis of inverter circuit has generally described by using normalized parameter and operating characteristics has been evaluated in terms of switching frequency and parameters. Based on the characteristics value a method of the circuit design is proposed. The theoretical results are in good agreement with the experimental ones. In the future this proposed circuit is considerated to be useful for induction heating and discharge lamp.

  • PDF

A study on the Push-Pull type high frequency resonant inverter (푸시-풀형 고주파 공진 인버터에 관한 연구)

  • 서철식
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.364-367
    • /
    • 2000
  • This paper describes a Push-Pull type high fre-quency resonant inverter conposed of consolidation of boost converter circuit and resonant circuit. By using a boost converter circuit the proposed inverter can obtain a twice input voltage of reson ant circuit and reduce a secondary turn ratios. By using both boost-converter and switching device can be reduce by half. Also the ana-lysis of the proposed circuit was described by using normalized parameter and operating characteristics have been evaluated as to switching frequency and parameters. In the future this pro-posed inverter shows that it can be practically used as a power source system for the lighting equipment of discharge lamp induction heating applications.

  • PDF

An Implementation of a Current Controlled Bi-directional Inverter with ZVT Switching (ZVT 스위칭 되는 전류제어형 양방향 인버터의 구현)

  • Lee S.R.;Ko S.H.;Kim S.W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.149-152
    • /
    • 2001
  • A Single-phase bi-directional inverter Using a diode bridge-type resonant circuit to implement ZVT(Zero Voltage Transition) switching is Presented. It is shown that the ZACE(Zero Average Current Error) algorithm based polarized ramptime current control can provide a suitable interface between diode bridge-type resonant circuit DC link and the inverter. The current control algorithm is analyzed about how to design the circuit with analyzed switch which m ZVT operation for the main power switch The simulation and experimental results would be shown to verify the proposed current algorithm, because the main power switch is turn on with ZVT and the bi-directional inverter is operated.

  • PDF

PERFORMANCE EVALUATIONS OF ADVANCED GENERATION IGBTS AND MCT IN SINGLE-ENDED RESONANT INVERTER

  • Ishimaru, N.;Fujita, A.;Hirota, I.;Yamashita, H.;Omori, H.;Nakamizo, Tetsuo;Shirakawa, S.;Nakaoka, Mutsuo.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.851-854
    • /
    • 1998
  • In recent years, a cost-effective voltage-source type single-ended resonant-load inverter using MOS gate power switching devices and its related resonant inverter topologies have been commonly used for induction-heated cooking appliances because of relatively-lowered switching losses, simple circuit topology, low cost, compactness and low harmonic current in utility AC side. This paper present some comparative performance evaluations of IGBTs as sample devices in each generation and MOS controlled Thyristor(MCT) incorporated into the voltage-source type single-ended load resonant inverter for induction-heating rice cookers used for consumer power electronic applications, in which the output power can be regulated on the basis of Frequency Modulation Scheme.

  • PDF

A Digitally Controlled Three-Phase Cycloconverter Type High Frequency AC Link Inverter Using Space Vector Modulation

  • Sha, Deshang;Qin, Zian;Wu, Dan;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.28-36
    • /
    • 2011
  • In this paper, a three phase cycloconverter type high frequency AC link inverter is discussed. The configuration consists of a high frequency full-bridge inverter and a high frequency transformer followed by a three phase cycloconverter whose switch is composed of anti-series connected MOSFETs with a common source. A simple digital control strategy based on space vector modulation (SVM) and repetitive control for the cycloconverter is proposed although its input voltage is a high frequency AC pulse. The operation principle of the proposed control strategy is analyzed and the equivalent working modes during one interval are also presented. The effectiveness of the proposed control strategy is verified through Matlab/Simulink simulations and experiments on a 1.45kW prototype.

Soft-Switching T-Type Multilevel Inverter

  • Chen, Tianyu;Narimani, Mehdi
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1182-1192
    • /
    • 2019
  • In order to improve the conversion efficiency and mitigate the EMI problem of conventional hard-switching inverters, a new soft-switching DC-AC inverter with a compact structure and a low modulation complexity is proposed in this paper. In the proposed structure, resonant inductors are connected in series for the arm branches, and resonant capacitors are connected in parallel for the neutral point branches. With the help of resonant components, the proposed structure achieves zero-current switching on the arm branches and zero-voltage switching on the neutral point branches. When compared with state-of-art soft-switching topologies, the proposed topology does not need auxiliary switches. Moreover, the commutation algorithm to realize soft-switching can be easily implemented. In this paper, the principle of the resonant operation of the proposed soft-switching converter is presented and its performance is verified through simulation studies. The feasibility of the proposed inverter is evaluated experimentally with a 2.4-kW prototype.

Comparative Analysis of Power Losses for Three-Level T-Type and NPC PWM Inverters (3-레벨 T-형 및 NPC 인버터의 전력 손실 비교 분석)

  • Alemi, Payam;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.173-183
    • /
    • 2014
  • In this paper, an analysis of power losses for the three-level T-type and neutral-point clamped (NPC) PWM inverters is presented, in which the conduction and switching losses of semiconductor devices of the inverters are taken into account. In the inverter operation, the conduction loss depends on the modulation index (MI) and power factor (PF), whereas the switching loss depends on the switching frequency. Power losses for the T-type and NPC inverters are analyzed and calculated at the different operating points of MI, PF and the switching frequency, in which the four different models of semiconductor devices are adopted. In the case of lower MI, the NPC-type is more efficient than the T-type, and vice versa. The validity of the power loss analysis has been verified by the simulation results.