• 제목/요약/키워드: inverter function

검색결과 330건 처리시간 0.026초

태양광발전소 운영유지보수를 위한 이기종 장비 지원 모니터링 시스템 (Heterogeneous Equipment Support Monitoring System for Operation and Maintenance of Solar power plant)

  • 임수창;홍석훈;박철영;조현욱;송법성;김종찬
    • 한국멀티미디어학회논문지
    • /
    • 제23권9호
    • /
    • pp.1171-1180
    • /
    • 2020
  • The number of the PV systems installed in south korea has been gradually increasing. Interest of operation & management of PV System is rising up as PV System installation trends to increase. The vital function of operation & management is the monitoring system. Most monitoring systems are only available for equipment of suppliers and manufacturers. In this study, a monitoring system was implemented to support multi-domain equipment (inverter, junction box, water distribution board, environmental sensors) that are not limited to specific manufacturers. Monitoring system includes a visualization function, which makes it easy for users to check the power generation and the operation status of the equipment of PV System. In the future, this monitoring system will be utilized as an operation & maintenance foundation element in the PV system industry.

Double Vector Based Model Predictive Torque Control for SPMSM Drives with Improved Steady-State Performance

  • Zhang, Xiaoguang;He, Yikang;Hou, Benshuai
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1398-1408
    • /
    • 2018
  • In order to further improve the steady-state control performance of model predictive torque control (MPTC), a double-vector-based model predictive torque control without a weighting factor is proposed in this paper. The extended voltage vectors synthesized by two basic voltage vectors are used to increase the number of feasible voltage vectors. Therefore, the control precision of the torque and the stator flux along with the steady-state performance can be improved. To avoid testing all of the feasible voltage vectors, the solution of deadbeat torque control is calculated to predict the reference voltage vector. Thus, the candidate voltage vectors, which need to be evaluated by a cost function, can be reduced based on the sector position of the predicted reference voltage vector. Furthermore, a cost function, which only includes a reference voltage tracking error, is designed to eliminate the weighting factor. Moreover, two voltage vectors are applied during one control period, and their durations are calculated based on the principle of reference voltage tracking error minimization. Finally, the proposed method is tested by simulations and experiments.

DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구 (A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP)

  • 서효룡;박영길;김종현;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

Multi-Function Distributed Generation with Active Power Filter and Reactive Power Compensator

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1855-1865
    • /
    • 2018
  • This paper presents a control strategy for voltage-controlled multi-function distributed generation (DG) combined with an active power filter (APF) and a reactive power compensator. The control strategy is based on droop control. As a result of local nonlinear loads, the voltages of the point of common coupling (PCC) and the currents injecting into the grid by the DG are distorted. The power quality of the PCC voltage can be enhanced by using PCC harmonic compensation. In addition, with the PCC harmonic compensation, the DG offers a low-impedance path for harmonic currents. Therefore, the DG absorbs most of the harmonic currents generated by local loads, and the total harmonic distortion (THD) of the grid connected current is dramatically reduced. Furthermore, by regulating the reactive power of the DG, the magnitude of the PCC voltage can be maintained at its nominal value. The performance of the DG with the proposed control strategy is analyzed by bode diagrams. Finally, simulation and experimental results verify the proposed control strategy.

A Novel Parameter-independent Fictive-axis Approach for the Voltage Oriented Control of Single-phase Inverters

  • Ramirez, Fernando Arturo;Arjona, Marco A.;Hernandez, Concepcion
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.533-541
    • /
    • 2017
  • This paper presents a novel Parameter-Independent Fictive-Axis (PIFA) approach for the Voltage-Oriented Control (VOC) algorithm used in grid-tied single-phase inverters. VOC is based on the transformation of the single-phase grid current into the synchronous reference frame. As a result, an orthogonal current signal is needed. Traditionally, this signal has been obtained from fixed time delays, digital filters or a Hilbert transformation. Nevertheless, these solutions present stability and transient drawbacks. Recently, the Fictive Axis Emulation (FAE) VOC has emerged as an alternative for the generation of the quadrature current signal. FAE requires detailed information of the grid current filter along with its transfer function for signal creation. When the transfer function is not accurate, the direct and quadrature current components present steady-state oscillations as the fictive two-phase system becomes unbalanced. Moreover, the digital implementation of the transfer function imposes an additional computing burden on the VOC. The PIFA VOC presented in this paper, takes advantage of the reference current to create the required orthogonal current, which effectively eliminates the need for the filter transfer function. Moreover, the fictive signal amplitude and phase do not change with a frequency drift, which results in an increased reliability. This yields a fast, linear and stable system that can be installed without fine tuning. To demonstrate the good performance of the PIFA VOC, simulation and experimental results are presented.

3치 논리 게이트를 이용한 3치 순차 논리 회로 설계 (The Design of the Ternary Sequential Logic Circuit Using Ternary Logic Gates)

  • 윤병희;최영희;이철우;김흥수
    • 대한전자공학회논문지SD
    • /
    • 제40권10호
    • /
    • pp.52-62
    • /
    • 2003
  • 본 논문에서는 3치 논리 게이트, 3치 D 플립플롭과 3치 4-디지트 병렬 입력/출력 레지스터를 제안하였다. 3치 논리 게이트는 n 채널 패스 트랜지스터와 뉴런 MOS(νMOS) 임계 인버터로 구성된다. 3치 논리 게이트들은 다양한 임계 전압을 갖는 다운 리터럴 회로를 사용하였고 전송함수를 바탕으로 설계되었다. 뉴런 MOS 트랜지스터는 다치 논리 구현에 가장 적합한 게이트이고 다양한 레벨의 입력 신호를 갖는다. 3치 D 플립 플롭과 3치 레지스터는 3치 데이터를 임시로 저장할 수 있는 저장 장치로 사용할 수 있다. 본 논문에서는 3.3V의 전원 전압을 사용하였고 0.35um 공정 파라미터를 이용하여 모의 실험을 통해 그 결과를 HSPICE로 검증하였다.

동적전압보상기의 과도특성을 개선하기 위한 디지털방식의 전향제어기 설계 (Design of the Feed Forward Controller in Digital Method to Improve Transient Characteristics for Dynamic Voltage Restorers)

  • 김효성;이상준;설승기
    • 전력전자학회논문지
    • /
    • 제9권3호
    • /
    • pp.275-284
    • /
    • 2004
  • 본 논문은 동적전압보상기(DVR)의 제어를 위한 우수한 성능의 디지털제어기를 제시하고 제어이득(Control Gain)의 설정에 관하여 논한다. DVR계통의 전력회로를 분석하여 DVR의 운전한계를 찾고 그에 따른 제어목표 및 제어기 구조를 제시한다. 디지털 제어기는 인버터의 PWM 스위칭과 함께 제어시스템의 시간지연을 야기한다. 이러한 시간 지연은 제어시스템의 전달함수를 1차수 높게 하여 제어시스템을 더한층 복잡하고 불안정하게 한다. 본 논문은 제어기의 시간지연을 고려하여 제안된 제어기의 이득을 설정하는 방법을 제시하고 인버터의 스위칭 주파수와 관련하여 출력측 필터요소의 설계지침을 제시한다. 제안된 설계방법에 의하여 전디지털화(Full Digital Control) 된 DVR 시스템을 제작하여 이론을 검증한다.

DSP기반 연료전지 하드웨어 시뮬레이터 구현 (Implementation of a DSP Based Fuel Cell Hardware Simulator)

  • 엄준현;임영철;정영국
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.59-68
    • /
    • 2009
  • 분산진원으로서 연료전지 발전장치는 100w부터 수백[kw]의 용량을 가지며 종전의 대규모 전력설비와 비교하여 높은 신뢰도를 갖는 고품질의 전력을 공급할 수 있다. 본 연구에서는 소형 분산전원으로서 PEMFC(polymer electrolyte membrane fuel cell)연료전지 발전장치에 대한 PSIM(power electronics simulation tool) 모델을 설정하고 이를 바탕으로 DSP(digital signal processor)기반의 연료전지 하드웨어 시뮬레이터를 구현하였다. 연료전지 전류와 출력전압과의 관계는 연료전지의 전압-전류(V-I) 곡선 중 ohmic영역에서 1차 함수로 간략화 하였다. 구현된 시스템은 PEMFC 하드웨어 시뮬레이터, 절연형 풀 브리지 직류 부스트 컨버터 그리고 60[Hz] PWM인버터로 구성되어있다. 부하변동 및 과도상태에 대한 연료전지 하드웨어 시뮬레이터의 전압-전류-전력(V-I-P) 특성을 파악하였으며, 저항 부하 및 비선형 부하에 대한 전력변환기의 60[Hz] 정현파 교류출력 전압파형을 고찰하였다.

회생전력 기능을 갖는 전기부하시험장치 개발 (Developement of Electrical Load Testing System Implemented with Power Regenerative Function)

  • 도왕록;채용웅
    • 한국전자통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.179-184
    • /
    • 2016
  • 본 연구를 통해 개발된 전기부하시험장치는 상용전원이 필요한 피시험장치(변압기, 정류기, 전압조정기, 인버터 등)와 상용전원이 불필요한 독립형 피시험장치(동력발전기, 풍력발전장치, 태양광발전장치, 하이브리드발전 장치, 배터리 등)에 대하여 정격용량시험이나 가변부하시험을 능동적으로 정밀하게 제어하면서도 시험 중에 사용되는 전기에너지를 소비하지 않고 전원변환장치를 통하여 계통선으로 전달하도록 설계되었다. 동기식 pwm 인버터회로를 상용전원과 연결시켜서 시험에 사용되는 전력을 계통선으로 귀환되도록 설계되었으며, 종전의 수동식 전기저항체를 사용한 전기부하시험장치에 비해 93.4% 정도의 전력을 소모하지 않고도 피시험체에 대한 시험이 가능하도록 하였다.

UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발 (Development of Digital Controller and Monitoring System for UPS Inverter)

  • 박지호;황기현;김동완
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.1-11
    • /
    • 2007
  • 본 논문에서는 UPS 인버터의 성능 개선을 위하여 출력측 LC 필터의 커패시터 전압과 전류의 2중 제어루프를 구성하고, 2중 제어루프에 디지털 제어시스템을 설계하였다. 또한, 디지털 제어기의 연산지연시간을 보상하기 위하여 이러한 연산지연시간을 인버터 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. UPS 인버터 출력전압의 과도상태 응답특성을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 2중 제어루프에서 내부 전류 제어루프는 내부 모델 제어기를 제안하였다. UPS 인버터 출력전압의 0의 정상상태 오차를 얻기 위하여 외부 전압 제어루프는 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 전압제어기를 제안하였다. 또한, 사용자에게 쉽게 UPS의 동작 상태를 표시하기 위하여 그래픽 사용자 인터페이스를 이용한 UPS의 모니터링 시스템을 구현하였다.