• Title/Summary/Keyword: inverter function

Search Result 330, Processing Time 0.022 seconds

Output LC Filter Design of Three Phase Voltage Source Inverter Considering the Performance of Controller (제어기 응답을 고려한 삼상 전압형 인버터의 출력 LC필터 설계)

  • 최재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.748-751
    • /
    • 2000
  • in this paper the design procedure of three phase voltage source inverter output filter is described. The 'd' axis transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form the capacitor value can be calculated with the system time constant is given as the closed,. form the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load is connected.

  • PDF

Output voltage PID control of three-phase Z-source inverter by detection of output voltage and input DC voltage (출력전압과 입력직류전압 검출에 의한 3상 Z-소스 인버터의 출력전압 PID 제어)

  • WU, Yan-Jun;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.171-172
    • /
    • 2011
  • The paper proposes a close loop control algorithm for Z-source inverter. The algorithm is realized by PWM duty ratio control in order to improve the output voltage to it's desired level. The controller consist of the output voltage PID controller and DC input voltage P controller. Using the DQ coordinate transformation simplify the controller design. The PSIM simulation results verify the validity by means of comparing the system with or without compensation and estimating if the system has output consistency function when ZSI's load and input voltage value changing.

  • PDF

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

Power Factor Correction of Single-phase Boost Converter for Low-cost Type UPS Configuration (저 가격형 UPS를 구성하기 위한 단상 부스트 컨버터의 고 역률 제어)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.145-150
    • /
    • 2013
  • A novel AC to DC PWM converters with unity input power factor are proposed to overcome the above shortcoming. The main function of these converters is to shape the input line current to force it exactly in phase with the input AC voltage. Therefore, the input power factor can be improved to near unity and the input current harmonics can be eliminated. In this paper, half-bridge converter with two active switches and two diodes are utilized for low-cost type UPS configuration. By having only two semiconductors in the current path at any time, losses can be reduced over the conventional boost topology. Also, this converter provides controllable dc-link voltage, high power factor, and low cost type converter by simple power circuits. Simulation results show that the proposed half-bridge converter/inverter control technique can be applied to single-phase low-cost type UPS systems successfully.

Study on Induction Motor Drive using Digitally Controlled Push-Pull Converter (디지털적으로 제어되는 푸쉬풀 컨버터를 사용하는 유도 전동기 드라이브에 대한 연구)

  • Kim, N.H.;Baik, W.S.;Choi, K.H.;Won, J.S.;Hwang, D.H.;Kim, M.H.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.478-480
    • /
    • 2008
  • On this paper, digitally controlled push-pull dc-dc converter and dc-ac inverter for induction motor control are presented, which is used one DSP(digital signal processor). This system has 12V battery input for the push-pull converter, and the push-pull converter generates 300V output for induction motor inverter input. In order to compensate the push-pull converter, the transfer function of push-pull converter is derived and digital PI compensator is adapted. Through bode diagram, stability of digital controlled push-pull converter is analyzed. To verify the proposed system, digital simulation of the induction motor drive using digital push-pull converter are performed.

  • PDF

Study on BLDC Motor Drive using Digitally Controlled Flyback-Converter (디지털적으로 제어되는 플라이백 컨버터를 사용하는 BLDC 전동기 드라이브에 대한 연구)

  • Kim, N.H.;Baik, W.S.;Choi, K.H.;Hwang, D.H.;Kim, M.H.;Won, J.S.;Kim, D.H.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.598-600
    • /
    • 2008
  • On this paper, digitally controlled flyback dc-dc converter and dc-ac inverter for bldc motor control are presented, which is used one processor. This system has 12V battery input for the flyback-converter, and the flyback-converter generates 30V output for BLDC motor inverter input. In order to compensate the flyback-converter, the transfer function of flyback converter is derived and digital PI compensator is adapted. Through bode diagram, stability of digital flyback-converter is analyzed. To verify the proposed system, digital simulation of the bldc motor drive using digital flyback-converter are performed.

  • PDF

Filter Design Method for an Inverter System (인버터 시스템을 위한 필터설계 방법)

  • 오진석
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.63-69
    • /
    • 1997
  • This paper presents a design method for a filter application in a parts-of FA(Factory Automation). Normal equations for ripple voltage and current are derived in terms of dimensionless quantities, and these equations can be used directly to evaluate the values of LC-filter components, taking into consideration the effect of the ripple components on the rms value of the PWM-generated ripple components. Using describing function technique, design equations of the filter are derived. The data needed for the filter evaluation are the amplitude of current ripple and the frequency of square pulses delivered by the HE(Harmonic Elimination) inverter algorithm. Experimental results show that the design of the filter can be based on the method proposed and that the filter can provide a significant reduction of ripple components.

  • PDF

THE EFFECTIVE VOLTAGE CONTROL SCHEME OF THE INVERTER FOR A STATIC POWER SUPPLY

  • Kim, Byoungjin;Song, Youngsin;Ji, Myoungku;Lee, Jongha;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.336-340
    • /
    • 1998
  • In this paper, an effective control scheme of a single phase UPS inverter is proposed to have no steady state error of the output voltage and the fast response for the load request. The cosine wave tranfer function is proposed to control the output voltage. This controller clearly removes errors of magnitude and phase both in the steady state. On the other hand, a current controller is proposed to reduce the transient time of the voltage control and to improve the bad distorted factor of the output voltage waveform by the load fluctuation and the presences of nonlinear parameters in the plant. The current controller is designed parallel to the voltage controller and performs separately from it.

  • PDF

Grid connected 3-phase inverter with photovoltaic generation, battery charger/discharger, and UPS function (태양광 발전-충방전기능-UPS 기능을 갖는 계통 연계형 15kW급 3상 인버터)

  • Kwon, Jungmin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.50.1-50.1
    • /
    • 2011
  • 전력수요가 적을 때 잉여전력을 저장하고 전력수요가 많은 시간대나 전기료가 비싼 시간대에 저장된 전력을 사용함으로서 전력의 활용 효율을 높이고, 전력공급 시스템을 안정화하기 위해 에너지저장시스템의 연구가 최근에 활발히 진행되고 있다. 또한 공장, 산업용빌딩이나 병원 등 고르고 안정적인 전력의 수요는 늘어나고 있으며, 화석 연료 고갈 문제로 인한 신재생에너지 발전의 중요성도 대두되고 있다. 본 논문에서는 무정전 전원장치, 태양광발전시스템, 에너지 저장 시스템을 모두 통합하였다. 제안한 시스템은 3상 인버터, 부스트 컨버터, 양방향 컨버터, 사이리스터 스위치로 구성된다. 인버터는 계통과 연계되거나 UPS 동작 시 AC 전력을 만든다. 부스트 컨버터는 태양광 패널과 연결되어 MPPT 제어를 수행한다. 양방향 컨버터는 잉여전력을 배터리에 저장을 하고, 전력이 부족할 시에는 배터리의 전력을 방전한다. 사이리스터 스위치는 정전 시 계통과 부하를 끊어주는 역할을 한다. 본 논문에서는 15kW급 시스템으로 구현하여 검증하였다.

  • PDF

CMOS Inverter Design based on Double Gate Ultra-Thin Body MOSFETs

  • Park, Sang Chun;Ahn, Yongsoo
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.343-346
    • /
    • 2015
  • Ultra-thin body transistor is one of the emerging devices since it control leakage current flows through substrate. In addition, it can be operated by double gates, thus, its on/off current ratio is higher than conventional counterpart. In this paper, we design and investigate a CMOS inverter based on ultra-thin body MOSFETs to estimate its performance in real application. NEGF (non-equilibrium Green's function) method is used to obatain relationship between drain current and voltage. DC transfer is extracted from the relationship, and FO4 (fanout-of-4) propagation delay is reported as 5.1 ps estimated by a simple model.

  • PDF