• 제목/요약/키워드: invariant subspace

검색결과 65건 처리시간 0.016초

TOTALLY REAL AND COMPLEX SUBSPACES OF A RIGHT QUATERNIONIC VECTOR SPACE WITH A HERMITIAN FORM OF SIGNATURE (n, 1)

  • Sungwoon Kim
    • 대한수학회지
    • /
    • 제61권3호
    • /
    • pp.547-564
    • /
    • 2024
  • We study totally real and complex subsets of a right quarternionic vector space of dimension n + 1 with a Hermitian form of signature (n, 1) and extend these notions to right quaternionic projective space. Then we give a necessary and sufficient condition for a subset of a right quaternionic projective space to be totally real or complex in terms of the quaternionic Hermitian triple product. As an application, we show that the limit set of a non-elementary quaternionic Kleinian group 𝚪 is totally real (resp. commutative) with respect to the quaternionic Hermitian triple product if and only if 𝚪 leaves a real (resp. complex) hyperbolic subspace invariant.

광대역 신호 처리에서의 도래각 추정 : Rotation of Signal Subspaces 방법 (Direction-of-Arrival Estimation in Broadband Signal Processing : Rotation of Signal Subspace Approach)

  • 김영수
    • 대한전자공학회논문지
    • /
    • 제26권7호
    • /
    • pp.166-175
    • /
    • 1989
  • 본 논문은 rotation of subspaces 개념을 이용한 도래각 추정 방법을 제시한다. 이 방법은 여러 응용분야에서 대두되는 부공간들(subspaces)의 각도 및 거리와 밀접한 관련이 있다. 먼저 최소 자승을 이용하여 한 부공간을 다른 부공간으로 변환 시켜주는 최적 변환 행렬을 구하기 위한 효율적인 방법을 유도하고 이를 이용하여 다중 광대역 신호들 (인코히어런트, 부분적인 코히어런트와 완전한 코히어런트의 혼합신호들)의 도래각을 추정한다. 대표적인 응용으로, 잡음의 배열 스펙트럼 밀도 행렬이 변하지 않는 액티브 시스템(e. g. sonar system) 경우에 성능을 높이기 위하여 효율적인 ROSS (rotation of signal subspaces) 알고리듬을 제안한다. ROSS 알고리듬은 Wang-Kaveh's CSS-focusing 방법에서 사용하는 예비처리와 공간 필터링을 필요로 하지 않는 장점이 있으며 일반적인 모든 배열 안테나에도 적용될 수 있다. 시뮬레이션 결과, 제안된 새로운 알고리듬이 CSS-focusing 방법 및 Forward-Backward Spatial Smoothed MUSIC 보다 높은 성능을 가짐을 알 수 있었다.

  • PDF

스탠드간 간섭현상을 고려한 연속 냉간압연기의 선형모델 규명 (Identification of Linear Model for Tandem Cold Mill Considering Interstand Interference)

  • 김인수;장유신;황이철;주효남;이만형
    • 한국정밀공학회지
    • /
    • 제17권8호
    • /
    • pp.78-86
    • /
    • 2000
  • This study identified a linear time-invariant mathematical model of each stand of a five-stand tandem cold mill. Two model identification methods are applied to construct a linear model of each stand of the tandem cold mill. For the model identification the input-output data that have interstand interference property in tandem cold rolling are obtained from a nonlinear simulator of the tandem cold mill. And a linear model of each stand is identified with N4SD(numerical algorithms for subspace state space system identification) method based on a state-space model and Least Square algorithm based on a transfer function. Furthermore a modeling error of the tandem cold mill is quantitatively analyzed from a maximum singular value plot of error function between an identified nominal model and uncertain model. In conclusion the comparison of the output signals between the existing Taylor linearized model the identified linear model and the nonlinear model of the tandem cold mill shows the accuracy and the applicability of the proposed identified model.

  • PDF

WEAKLY DENSE IDEALS IN PRIVALOV SPACES OF HOLOMORPHIC FUNCTIONS

  • Mestrovic, Romeo;Pavicevic, Zarko
    • 대한수학회지
    • /
    • 제48권2호
    • /
    • pp.397-420
    • /
    • 2011
  • In this paper we study the structure of closed weakly dense ideals in Privalov spaces $N^p$ (1 < p < $\infty$) of holomorphic functions on the disk $\mathbb{D}$ : |z| < 1. The space $N^p$ with the topology given by Stoll's metric [21] becomes an F-algebra. N. Mochizuki [16] proved that a closed ideal in $N^p$ is a principal ideal generated by an inner function. Consequently, a closed subspace E of $N^p$ is invariant under multiplication by z if and only if it has the form $IN^p$ for some inner function I. We prove that if $\cal{M}$ is a closed ideal in $N^p$ that is dense in the weak topology of $N^p$, then $\cal{M}$ is generated by a singular inner function. On the other hand, if $S_{\mu}$ is a singular inner function whose associated singular measure $\mu$ has the modulus of continuity $O(t^{(p-1)/p})$, then we prove that the ideal $S_{\mu}N^p$ is weakly dense in $N^p$. Consequently, for such singular inner function $S_{\mu}$, the quotient space $N^p/S_{\mu}N^p$ is an F-space with trivial dual, and hence $N^p$ does not have the separation property.

IFSA 알고리즘을 이용한 유전자 상호 관계 분석 (Analysis of Interactions in Multiple Genes using IFSA(Independent Feature Subspace Analysis))

  • 김혜진;최승진;방승양
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제33권3호
    • /
    • pp.157-165
    • /
    • 2006
  • 세포는 환경 변화 및 자극으로부터 자신을 보호하기 위해 유전자가 발현하여 생명을 유지 시스템을 갖고 있다. 유전자의 발현은 비정상적인 상태의 세포를 환경을 조절, 변화시켜 정상으로 바꾸기 위한 기능, 발달단계에 필요한 기능 등 생명현상에 필요한 특수 역할을 수행한다. 따라서 각 유전자의 기능을 아는 것은 생물학적으로 상당히 의미 있는 일이다. 본 논문에서는 유전자 기능을 알아보기 위해 발현 패턴을 통해 같을 때, 유사한 형태 혹은 시차를 갖고 동일한 형태로 발현하는 유전자들은 같은 기능을 한다는 가정을 하였다. 이 가정에 기반하여 각 유전자들을 기능에 따라 분류하였다. (1) IFSA선형 모델을 적용하여 데이타를 잘 나타내 줄 수 있는 특징 패턴을 찾았으며 (2) 이 특징 패턴으로부터 본 논문에서 제안한 Membership Scoring Function을 이용하여 유전자를 필터링(filtering) 하였다. 이 유전자들은 기존의 ICA(Independent Component Analysis) 방법에서 보다 IFSA 방법이 더 효과적으로 각 기능에 따른 유전자 그룹을 찾아내줌을 GO(Gene Ontology)에서 확인할 수 있었다. 이는 시차 혹은 위상 변화에 상관없이 데이타를 잘 나타낼 수 있는 IFSA의 특성이, ICA보다. 생물학적인 변수를 더 고려해 줄 수 있기 때문이라고 생각된다[1]. 이 논문의 또 다른 주요 작업은 유전자의 상호작용 관계로부터 유전자 네트웍을 얻어내는 것이다. 유전자 네트웍은 같은 그룹 내에서 유전자간의 상관 계수를 구하고 가장 높은 상관도를 보이는 유전자쌍을 연결시켜 얻게되었다. 이 네트웍 역시 GO 해석에서 그 유효성을 확인하였다.를 평균 66.02에서 58.98로 줄이면서 계산시간은 평균 71ms에서 44ms 으로 빠르게 됨을 알 수 있었다.적외선 분광법을 이용한 사일리지의 화학적 조성분 함량 측정은 적은 오차 범위 내에서 신속하고 정확한 분석법이 될 수 있음을 확인 할 수 있었다. 비록 원물 생시료(IF)에 대한 직접적인 측정은 다소 예측 정확성이 떨어지지만 현장 적용성과 편리성을 높이기 위해서는 생시료의 측정시 오차를 줄일 수 있는 스펙트럼의 수처리 방법이나 산란보정 방법과 같은 데이터 처리기법에 대한 더 많은 연구가 앞으로 진행되어야 한다고 생각되어진다.상자의 50% 이상이 매일 생선 콩 및 콩제품과 채소류를 먹고 있었고, 인스턴트나 패스트푸드는 정상 체중군이 저체중군이나 과체중보다 매일 섭취하는 빈도가 낮았다(p<0.0177). 7. 가장 낮은 영양 섭취 상태를 보여준 영양소(% RDA< 75%)는 철분과 칼슘으로 조사 대상자의 3/4에 해당하는 조사 대상자가 영양 부족 상태였다. 칼슘 섭취의 경우 정상 체중군이 과체중군과 저체중군보다 섭취율이 낮았으나(p<0.0257) 철분은 군간 유의차는 없었다. 8. 칼슘의 경우 과체중군이 저체중군이나 정상 체중군에 비해 영양소 적정비율(NAR) 값이 높았으며(p<0.0257) 철분, 단백질, 비타민 $B_1$$B_2$, 나이아신의 경우도 통계적으로 유의하지는 않으나 과체중군이 저체중군 또는 정상 체중군의 NAR 값이 높은 경향을 보여주었다. 9가지 영양소의 NAR을 평균한 MAR 값은 군간 유의적이지는 않으나 과체중군(0.76)이 정상체중(0.73) 또는 저체중군(0.73)에 비해 높은 값은 보여주었다. 9.