• Title/Summary/Keyword: intrauterine insemination

Search Result 60, Processing Time 0.027 seconds

A New Device for Intrauterine Artificial Insemination in the Dog

  • Kong, I.K.;Yu, D.J.;Jeong, S.R.;Oh, I.S.;Yang, C.J.;Cho, S.G.;Bae, I.H.;Oh, D.H.;Kim, H.R.;Cho, S.K.;Park, C.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.2
    • /
    • pp.180-184
    • /
    • 2003
  • The intrauterine inseminator (IUI) was developed to provide the method of depositing dog semen into the uterine body instead of the vagina. The IUI consists of a vaginal endoscope, a balloon sheath, and injection catheter. When the endoscope is inserted into the vagina and the balloon expanded with air, the cervical os becomes visible so a injection catheter can be inserted through the cervix for deposition of the frozen-thawed semen. The efficacy of the IUI device was compared to intra-vaginal artificial insemination using semen that had been collected and frozen from pooled sperm-rich fraction of ejaculates collected from two Jindo dog donors. Aliquots of semen were extended with a Tris-egg yolk diluent, centrifuged, the seminal plasma removed, the pellet resuspended with the same diluent, and cooled to $5^{\circ}C$ over a 2 h period. A Tris-egg yolk-glycerol extender was added at $5^{\circ}C$; after 1 h, semen was loaded into 0.5 ml straws, and straws were frozen in LN vapor for 5 min, and immersed in LN for storage. The final sperm concentration for freezing was approximately $100{\times}10^{6}cells/ml$. The straws were thawed at $70^{\circ}C$ for precisely 6 sec, 1.5 ml Tris-egg yolk buffer at $38^{\circ}C$ added, and the 2 ml of thawed semen was used for a single insemination using the IUI device. Each bitch was inseminated at optimal insemination point, which was estimated by vaginal epithelial cells staining and progesterone concentration analysis. Use of the IUI device resulted in 21 of 26 females giving birth to 89 pups ($4.2{\pm}1.6$ pups per litter), while intra-vaginal AI resulted in 6 of 15 females whelping a total of 17 pups ($2.8{\pm}1.2$ pups per litter). We believe the IUI device is easier to use than previously described devices used for intrauterine insemination. In our experience the expansion of the balloon has a calming effect on the bitch that aids the inseminator. These results indicate that the IUI device was able to provide high fertility with 50 million frozen sperm per insemination and two inseminations.

Production of Kittens from Non-Surgical Intrauterine Insemination of Frozen Epididymis Semen in Cat

  • Lee, Young-Ho;Yu, Dae-Joong;Lee, Hyo-Sang;Seo, Youn-Gil;Jeon, Se-Sin;Cho, Su-Jin;Kim, Young-Ho;Yin, Xi-Jun;Cho, Seong-Kyun;Bae, In-Hyu;Kong, Il-Keun
    • Proceedings of the KSAR Conference
    • /
    • 2004.06a
    • /
    • pp.245-245
    • /
    • 2004
  • This study was carried out to evaluate the possibility of production of kittens by a non-surgical intrauterine insemination (NIUI) or intra-vaginal insemination (IVI) with the Norwegian catheter and using a frozen epididymal sperm (FES). Semen was collected epididymal sperm and frozen in Tris-buffered with 50 × 10/sup 6//㎖. The motility and progressive motility of FES was approximately 40.3±5.8% and 35.9±6.5% after thawing. (omitted)

  • PDF

Evidence for obtaining a second successive semen sample for intrauterine insemination in selected patients: results from 32 consecutive cases

  • Ortiz, Alejandra;Ortiz, Rita;Soto, Evelyn;Hartmann, Jonathan;Manzur, Alejandro;Marconi, Marcelo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.43 no.2
    • /
    • pp.102-105
    • /
    • 2016
  • Objective: The goal of this study was to compare the semen parameters of two successive samples obtained within an interval of less than 60 minutes from patients planning to undergo intrauterine insemination (IUI) whose first samples exhibited low semen quality. Methods: Thirty-two consecutive patients were enrolled in the study. On the day of IUI, the semen analysis of the samples initially presented by all patients met at least two of the following criteria: sperm concentration $<5{\times}10^6/mL$, total sperm count $<10{\times}10^6$, progressive sperm motility (a+b) in the native sample <30%, and total motile sperm count (TMSC) $<4{\times}10^6$. A successive semen sample was obtained no more than 60 minutes after the first sample. Results: Compared to the first sample, the second exhibited significantly (p<0.05) improved sperm concentration, TMSC, progressive motility, and vitality. Regarding TMSC, the most critical parameter on the day of IUI, 23 patients (71.8%) improved it, while nine (28.2%) displayed poorer outcomes. Conclusion: In defined cases, requesting a second successive ejaculate on the day of insemination may result in a high percentage of cases in an improvement of the quality of the sample.

Pregnancy Rate by Intrauterine Insemination (IUI) or Timed-Intercourse In Stimulated Cycles with Clomiphene Citrate and Gonadotropins (Clomiphene Citrate와 성선자극호르몬을 병합한 배란유도주기에서 성교와 인공수정에 의한 임신율의 비교)

  • Hong, Jeong-Eui;Lee, Ji-Sam
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.1
    • /
    • pp.31-41
    • /
    • 1999
  • To evaluate the effectiveness of intrauterine insemination (IUI) in the treatment of infertility, timed-intercourse and intrauterine insemination by husband in stimulated cycles with clomiphene citrate and gonadotropins were compared in a total of 105 cycles. Patients received 100mg of clomiphene citrate daily for 5 days starting on day 3 of the menstrual cycle followed by hMG or FSH. Doses of exogenous gonadotropins were adjusted by the follicular development and concentrations of serum estradiol $(E_2)$. More than 3 follicles reaching >16 mm were present in the ovary, 5,000 IU of hCG was administered intramusculary. Patients received a maximum of three intercourse or IUI cycles for the treatment. Severe male (<$10{\times}10^6$ motile sperm) or age factor (>39 y) patients were excluded in this study. Pregnancy was classified as clinical if a gestational sac or fetal cardiac activity was seen on ultrasound. The overall clinical pregnancy rates were 17.1% per cycle (18/105) and 21.2% per patient (18/85). The pregnancy rates (per cycle) were 17.5% (11/63) in intercourse and 16.7% (7/42) in IUI groups, respectively. IUI had no significant improvement in pregnancy rate compared with timed-intercourse. The multiple pregnancy rates were 11.1% (1 twin and 1 triplet). No patient developed ovarian hyperstimulation. Abortion rate was 28.6% (2/7) in IUI group only. The delivery and ongoing pregnancy rates were 15.2% per cycle (16/105) and 18.8% per patient (16/85). There were no differences in age, duration of infertility, follicle size and level of estradiol $(E_2)$ on the day of hCG injection in pregnant and non-pregnant groups. However, total doses of gonadotropins were higher in pregnant group than in non-pregnant group (p<0.01). Pregnancy rate was not affected by ovulatory status at the time of insemination. These results indicate that well timed-intercourse in stimulated cycles is as effective as IUI for infertile couples.

  • PDF

Production of Pups Following Artificial Insemination by Canine Intrauterine Inseminator (개 자궁내 인공수정기에 의한 인공수정 후 산자생산)

  • 공일근;조성균;임용택;이상인;위성하
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.375-380
    • /
    • 1999
  • This study was conducted to develop an intrauterine inseminator (IUI) to deposit of frozen semen into uterus and to evaluate the results obtained after artificial insemination by IUI. Two Japanese spitzs (2 to 4 years of age) were used as semen donors. Semen was collected by manual masturbation into sterile glass collection tubes and separated into 3 fractions with only the sperm-rich fractions retained for further examination. Sperm motility >70%, sperm concentration of 200 to $400{\times}10^6 cells/ml$$\times$g for 5 min and poured out the suspended solution, and then diluted with 2 ml Tris-buffer which was consisted of 2.4 g Tris, 1.4 g citric acid, 0.8 g glucose, 0.1 $\mu\textrm{g}$/ml streptomycin, 100 IU/ml penicillin, 20 ml egg yolk to 100 ml mili-Q water (Ext I) or supplemented with 8 ml glycerol and 1 ml Equex STM paste to 100 rnl (Ext II). The diluted semen was cooled to 5$^{\circ}C$ in cold room, where the temperature in the sample reached 5$^{\circ}C$. Two h after beginning the cooling procedure, 2 ml of Ext II, also at 5$^{\circ}C$, was added and mixed by gently reversing the tubes several times during 1 h. The final sperm concentration for freezing was approximately $50{\times}10^6 cells/ml$. After equilibration, the semen was loaded into 0.5 ml straw and frozen on the liquid nitrogen vapour in styrofoam box. The straws were thawed at 7$0^{\circ}C$ for precisely 6 sec. After thawing of each straw, the frozen semen can survived over 50% motility. All the females were inseminated twice with 1 ml of $25{\times}10^6 cells/ml$

  • PDF

Predictive value of sperm motility characteristics assessed by computer-assisted sperm analysis in intrauterine insemination with superovulation in couples with unexplained infertility

  • Youn, Joung-Sub;Cha, Sun-Hwa;Park, Chan-Woo;Yang, Kwang-Moon;Kim, Jin-Yeong;Koong, Mi-Kyoung;Kang, Inn-Soo;Song, In-Ok;Han, Sang-Chul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • Objective: To determine whether characteristics of sperm motility obtained by computer-assisted sperm analysis (CASA) could predict pregnancy after intrauterine insemination (IUI) in couples with unexplained infertility. Methods: Three hundred eighty-three cycles of intrauterine insemination with superovulation were retrospectively analyzed. Semen analysis was performed with CASA before and after swim-up and the parameters were compared between pregnant and non-pregnant women. Results: The pregnancy rate per cycle was 14.1%. Pregnant and non-pregnant women were comparable in terms of age, infertility duration, the number of dominant follicles. While sperm concentration, motility, and parameters such as average path velocity (VAP) and percentage rapid (RAPID) before semen preparation were significantly different between the pregnancy and non-pregnancy groups, there were no differences in sperm parameters when comparing the two groups after preparation. Using a receiver operating characteristic curve to measure sensitivity and specificity, the optimal threshold value for the predictors of pregnancy was revealed to be a concentration of ${\geq}111{\times}10^6/mL$, a motility of ${\geq}$ 51.4%, and RAPID ${\geq}$ 30.1% before preparation for IUI. Conclusion: Sperm parameters including concentration, motility, and RAPID before sperm preparation could have predictive value for pregnancy outcome after intrauterine insemination with superovulation in couples with unexplained infertility, and would be helpful when counseling patients before they make the decision to proceed with IVF/ICSI-ET.

Stimulated intrauterine insemination in women with unilateral tubal occlusion

  • Yi, Gwang;Jee, Byung Chul;Suh, Chang Suk;Kim, Seok Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.39 no.2
    • /
    • pp.68-72
    • /
    • 2012
  • Objective: To investigate the value of stimulated intrauterine insemination (IUI) in women with unilateral tubal occlusion. Methods: Superovulation and IUI was performed during 2003-2010 and the medical records were reviewed retrospectively. Thirty-seven infertile women (52 cycles) with unilateral tubal occlusion diagnosed by hysterosalpingography and without other causes of infertility were selected. One-hundred fourteen patients with unexplained infertility served as a control group (182 cycles). The main outcome was the clinical pregnancy rate per cycle. Results: The pregnancy rate per cycle was similar, 17.3% for the unilateral tubal occlusion group and 16.5% for the unexplained infertility group. The rate of miscarriage (11.1% vs. 23.3%) and ectopic pregnancy (11.1% vs. 6.7%) was similar between the two groups. The pregnancy rate was higher in patients with proximal occlusion (25.0%) compared with distal occlusion (13.9%) or unexplained infertility, but not statistically significant. Conclusion: Stimulated IUI can be suggested as the initial treatment option in women with unilateral proximal or distal tubal occlusion.

Body composition: A predictive factor of cycle fecundity

  • Kayatas, Semra;Boza, Aysen;Api, Murat;Kurt, Didar;Eroglu, Mustafa;Arinkan, Sevcan Arzu
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.41 no.2
    • /
    • pp.75-79
    • /
    • 2014
  • Objective: To study the effect of body composition on reproduction in women with unexplained infertility treated with a controlled ovarian hyperstimulation and intrauterine insemination programme. Methods: This prospective observational study was conducted on 308 unexplained infertile women who were scheduled for a controlled ovarian hyperstimulation and intrauterine insemination programme and were grouped as pregnant and non-pregnant. Anthropometric measurements were performed using TANITA-420MA before the treatment cycle. Body composition was determined using a bioelectrical impedance analysis system. Results: Body fat mass was significantly lower in pregnant women than in non-pregnant women ($15.61{\pm}3.65$ vs. $18.78{\pm}5.97$, respectively) (p=0.01). In a multiple regression analysis, body fat mass proved to have a stronger association with fecundity than the percentage of body fat, body mass index, or the waist/hip ratio (standardized regression coefficient${\geq}0.277$, t-value ${\geq}2.537$; p<0.05). The cut-off value of fat mass, which was evaluated using the receiver operating characteristics curve, was 16.65 with a sensitivity of 61.8% and a specificity of 70.2%. Below this cut-off value, the odds of the pregnancy occurrence was found to be 2.5 times more likely. Conclusion: Body fat mass can be predictive for pregnancy in patients with unexplained infertility scheduled for a controlled ovarian hyperstimulation and intrauterine insemination programme.

A Comparison Study of Single with Double Intrauterine Insemination with Mild Ovarian Hyperstimulation for Infertility Patients (불임 환자의 치료에서 Mild Ovarian Hyperstimulation을 이용한 Single IUI와 Double IUI의 비교)

  • Son, Young-Soo;Lee, Sang-Hoon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.31 no.3
    • /
    • pp.191-200
    • /
    • 2004
  • Objective: To compare the clinical efficacy of double intrauterine insemination with single intrauterine insemination in GnRH antagonist combined ovarian hyperstimulation (Mild ovarian hyperstimulation) Materials and Methods: From Jan. 2001 to Jul. 2004, a retrospective clinical analysis was done of a total of 295 cycles in 170 patients who underwent ovarian hyperstimulation for ART (assisted reproductive technique). Subjects were divided into three groups; only clomiphene citrate ovarian hyperstimulation (n=55, 95cycles), GnRH antagonist combined ovarian hyperstimulation (soft ovarian hyperstimulation) (n=66 99cycles), and GnRH agonist combined ovarian hyperstimulation (short protocol) (n=49, 101cycles) Each group were randomly devided into two subgroups. One group underwent single IUI and the other group underwent double IUI. Results: GnRH antagonist group and GnRH agonist group had similar pregnancy rate. In GnRH antagonist Group, pregnancy rate was 36.1% in single IUI subgroup and was 36.6% in double IUI subgroup. These finding were not statistically significant. And Pregnancy rate was 20.8% in single IUI subgroup and was 19.3% in double IUI subgroup in single clomiphene citrate group, and 36.3% in single IUI subgroup and was 33.3% in double IUI subgroup in GnRH agonist group. These finding were not statistically significant, too. Conclusion: Pregnancy rate of GnRH antagonist was high and complication rate such as OHSS and multiple pregnancy was lower. In GnRH antagonist group, to compare with single IUI and double IUI, the result do not statistically differ. So GnRH antagonist single injection with single IUI was relatively comparable ART in infertiliry patient.

Predictive value of sperm motility before and after preparation for the pregnancy outcomes of intrauterine insemination

  • Jeong, Mina;Kim, Seul Ki;Kim, Hoon;Lee, Jung Ryeol;Jee, Byung Chul;Kim, Seok Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.48 no.3
    • /
    • pp.255-261
    • /
    • 2021
  • Objective: This study aimed to investigate sperm motility and its changes after preparation as predictors of pregnancy in intrauterine insemination (IUI) cycles. Methods: In total, 297 IUI cycles from January 2012 to December 2017 at a single tertiary hospital were retrospectively analyzed. Patient and cycle characteristics, and sperm motility characteristics before and after processing were compared according to clinical pregnancy or live birth as outcomes. Results: The overall clinical pregnancy rate per cycle was 14.5% (43/297) and the live birth rate was 10.4% (30/289). Patient and cycle characteristics were similar between pregnant and non-pregnant groups. Sperm motility after preparation and the total motile sperm count before and after processing were comparable in terms of pregnancy outcomes. Pre-preparation sperm motility was significantly higher in groups with clinical pregnancy and live birth than in cycles not resulting in pregnancy (71.4%±10.9% vs. 67.2%±11.7%, p=0.020 and 71.6% ±12.6% vs. 67.3%±11.7%, p=0.030, respectively). The change in sperm motility after processing was significantly fewer in the non-pregnant cycles, both when the comparison was conducted by subtraction (post-pre) and division (post/pre). These relationships remained significant after adjusting for the female partner's age, anti-Müllerian hormone level, and number of pre-ovulatory follicles. According to a receiver operating characteristic curve analysis, an initial sperm motility of ≥72.5% was the optimal threshold value for predicting live birth after IUI. Conclusion: Initial sperm motility, rather than the motility of processed sperm or the degree of change after preparation, predicted live birth after IUI procedures.