• Title/Summary/Keyword: intervertebral cage

Search Result 27, Processing Time 0.02 seconds

A Research on the Reliability Assessment and Improvement of Spinal Cage using by the Failure Mechanism by the Impulse (충격량에 의한 고장메커니즘을 활용한 추간체유합보형재의 신뢰성 평가 방법 및 개선에 관한 연구)

  • Yu, Woo-Jin;Lee, Yong-Yoon;Heo, Sung-Yong;Ham, Jung-Koel
    • Journal of Applied Reliability
    • /
    • v.14 no.4
    • /
    • pp.243-247
    • /
    • 2014
  • The Spinal cage is the cage-shaped implantable medical device used to treat structural abnormalities caused by degenerative intervertebral disks. In order to secure enough space to provide the mechanical stability and the intervertebral fusion, after removing the intervertebral disc, the Spinal cage is transplanted between the intervertebral space. A hammer is used to push the spinal cage into a narrow space during the spinal cage transplant surgery. Due to the impact and pressure, damage occurs frequently on the spinal cage. In this study, a test model is constructed to measure the value of impulse generally applied on the Spinal cage. The figures of internal impulse before and after the improvement of the Spinal cage are then compared to suggest direction to improve the reliability of the spinal cage.

A Study about Cervical Cage Structural Analysis Using Finite Element Method (FEM 을 이용한 경추용 Cage 의 구조해석)

  • 정우철;최진화;최길운;김성민;조명우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.137-140
    • /
    • 2004
  • Intervertebral cages in the cervical spine have been advantage in spinal fusion to relieve low back pain. In this study the effects of an intervertebral cage insertion on a cervical spine functional spinal unit investigate and cage structural analysis using finite element method. Three-Dimensional finite element models to create computed tomography (CT) scan C3-C4, obtain healthy young male which 1-mm slice section.

  • PDF

Numerical Analysis on Stress Distribution of Vertebra and Stability of Intervertebral Fusion Cage with Change of Spike Shape (척추체간 유합케이지의 스파이크형상 변화에 따른 척추체의 응력분포 및 케이지의 안정성에 대한 수치적 해석)

  • 심해영;김철생;오재윤
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.361-367
    • /
    • 2004
  • The axial compressive strength, relative 3-D stability and osteoconductive shape design of an intervertebral fusion cage are important biomechanical factors for successful intervertebral fusion. Changes in the stress distribution of the vertebral end plate and in cage stability due to changes in the spike shape of a newly contrived box-shaped fusion cage are investigated. In this investigation, the initial contact of the cage's spikes with the end plate and the penetration of the cage's spikes into the end plate are considered. The finite element analysis is conducted to study the effects of the cage's spike height, tip width and angle on the stress distribution of the vertebral end plate, and the micromigration of the cage in the A-P direction. The stress distribution in the end plate is examined when a normal load of 1700N is applied to the vertebra after inserting 2 cages. The micromigration of the cage is examined when a pull out load of l00N is applied in the A-P direction. The analysis results reveal that the spike tip width significantly influences the stress concentration in the end plate, but the spike height and angle do not significantly influence the stress distribution in the end plate touching the cage's spikes. In addition, the analysis results show that the micromigration of the cage can be reduced by adjusting the spike angle and spike arrangement in the A-P direction. This study proposes the optimal shape of an intervertebral fusion cage, which promotes bone fusion, reduces the stress concentration in a vertebral end plate, and increases mechanical stability.

Design and testing of a minimally invasive intervertebral cage for spinal fusion surgery

  • Anderson, Walter;Chapman, Cory;Karbaschi, Zohreh;Elahinia, Mohammad;Goel, Vijay
    • Smart Structures and Systems
    • /
    • v.11 no.3
    • /
    • pp.283-297
    • /
    • 2013
  • An innovative cage for spinal fusion surgery is presented within this work. The cage utilizes shape memory alloy for its hinge actuation. Because of the use of SMA, a smaller incision is needed which makes the cage deployment minimally invasive. In the development of the cage, a model for predicting the torsional behavior of SMAs was developed and verified experimentally. The prototype design of the cage was developed and manufactured. The prototype was subjected to static tests per ASTM specifications. The cage survived all of the tests, alluding to its safety within the body.

Testing Evaluation for Stand-Alone Cervical Cage (경추용 자립형 케이지의 실험적 평가)

  • Baek, Myong-Hyun;Lee, Mun-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.11
    • /
    • pp.937-941
    • /
    • 2016
  • Stand-alone cervical cage consists of a PEEK body, Ti plate, and screw, which are configured as a single-piece. Through a single operation, this implantable medical device is capable of completely fixing the cervical vertebral body. For example, instead of a plate, which is normally used, the intervertebral disc is removed and replaced with a cervical cage. It should be noted that in Korea, KFDA guidelines for a stand-alone cervical cage have not yet been suggested. Therefore, the aim of this study is to present the systematic study of the static compression test, static torsion test, dynamic compression test, and expulsion test. Further, the test method is designed to refer to the ASTM standard and relative literature.

Wedge Shape Cage in Posterior Lumbar Interbody Fusion : Focusing on Changes of Lordotic Curve

  • Kim, Joon-Seok;Oh, Seong-Hoon;Kim, Sung-Bum;Yi, Hyeong-Joong;Ko, Yong;Kim, Young-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.255-258
    • /
    • 2005
  • Objective : Lumbar lordotic curve on L4 to S1 level is important in maintaining spinal sagittal alignment. Although there has been no definite report in lordotic value, loss of lumbar lordotic curve may lead to pathologic change especially in degenerative lumbar disease. This study examines the changes of lumbar lordotic curve after posterior lumbar interbody fusion with wedge shape cage. Methods : We studied 45patients who had undergone posterior lumbar interbody fusion with wedge shape cage and screw fixation due to degenerative lumbar disease. Preoperative and postoperative lateral radiographs were taken and one independent observer measured the change of lordotic curve and height of intervertebral space where cages were placed. Segmental lordotic curve angle was measured by Cobb method. Height of intervertebral space was measured by averaging the sum of anterior, posterior, and midpoint interbody distance. Clinical outcome was assessed on Prolo scale at 1month of postoperative period. Results : Nineteen paired wedge shape cages were placed on L4-5 level and 6 paired same cages were inserted on L5-S1 level. Among them, 18patients showed increased segmental lordotic curve angle. Mean increased segmental lordotic curve angle after placing the wedge shape cages was $1.96^{\circ}$. Mean increased disc height was 3.21mm. No cases showed retropulsion of cage. The clinical success rate on Prolo's scale was 92.0%. Conclusion : Posterior lumbar interbody fusion with wedge shape cage provides increased lordotic curve, increased height of intervertebral space, and satisfactory clinical outcome in a short-term period.

The Efficacy of Titanium Mesh Cage in Tuberculous Spondylitis Treated with Anterior Intervertebral Fusion (척추 결핵의 전방유합술시 Titanium Mesh Cage의 효과)

  • Jeong, Ju-Ho;Lee, Sang-Gu;Yoo, Chan-Jong;Han, Ki-Soo;Kim, Woo-Kyung;Kim, Young-Bo;Park, Cheol-Wan;Lee, Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.998-1003
    • /
    • 2001
  • Objective : The maintenance of the correction of kyphotic deformity is one of the difficult problem in tuberculous spondylitis after anterior debriment and fusion with tricortical bone graft. The goal of this study is to find out the efficacy of titanium mesh cage impacted with autogenous bone chip in tuberculous spondylitis treated with anterior intervertebral fusion. Materials and Method : Twelve patients were treated with anterior intervertebral fusion using titanium mesh cage for tuberculous spondylitis from January 1996 to June 1999. We analized the changes in the correction of kyphotic deformity, changes of ESR and CRP, fusion state and recurrence after anterior intervertebral fusion with titanium mesh cage. Results : Clinical symptoms were improved in all twelve patients without any neurologic complications. The mean kyphotic angle corrected was 7.3 degrees immediately after operation, but the loss of correction of kyphotic angle was 2.2 degrees after 3 months and 2.6 degrees after 6 months. We found that the loss of correction of kyphotic deformity occurred mainly within the first 3 months after surgery. Only one patient, suffered from acute hepatic failure after first operation and had an insufficient anti-tuberculous medication therapy, showed recurrence of tuberculous spondylitis after 6 months. The patient underwent a second operation with posterior fixation procedure with good outcome. The changes of ESR and CRP were not specifically important factor to reveal recurrence of tuberculosis of the spine in our series. Conclusion : The surgical procedure of tuberculous spondylitis using titanium mesh cage with bone chip seems to be an effective procedure to minimize loss of the correction of kyphotic deformity without any aggravating inflammatory change and recurrence with titanium mesh cage, when sufficient debridement and anti-tuberculous chemotherapy are achieved.

  • PDF

Comparision of the Two Groups between Autologous Bone Chips and Cage as Posterior Lumbar Interbody Fusion in Spondylolisthesis Patients (요추전방전위증 환자들에서 후방요추체간유합술로 자가골편 또는 Cage를 사용한 두 군간의 비교)

  • Shin, Pill Jae;Kim, Chang Hyun;Moon, Jae Gon;Lee, Ho Kook;Hwang, Do Yun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.507-513
    • /
    • 2000
  • Objective : Posterior lumbar interbody fusion(PLIF) with transpedicular screw fixation(TPSF) have many merits in the treatment of spondylolisthesis. The aim of this study was to compare cage PLIF group(PLIF using cage and TPSF) with chip PLIF group(PLIF using autologous bone chips and TPSF) as surgical treatment of spondyloisthesis. Methods : PLIF and TPSF were performed in 44 patients with spondylolisthesis from January 1994 to December 1998. The surgical methods were divided into two groups. One group was cage PLIF(20 patients), and the other group was chip PLIF(24 patients). We analyzed the change of anterior translation, change of intervertebral space height, fusion rate, clinical outcomes, and postoperative complications in two groups. Result : There was no significant difference in reduction and maintenance of anterior translation between two groups. Intervertebral space height was increased in the two groups at immediate postoperative state. At last followup, it was decreased compared to preoperative height in chip PLIF group. In cage PLIF group, last follow-up height was decreased compared to immedate postoperative height, but it was significantly increased compared to preoperative height. Fusion rates were 70.9% and 90% in chip PLIF group and cage PLIF group, respectively. Excellent and good clinical outcomes were 79.2% in chip PLIF group and 85% in cage PLIF group, but there was no statistical significance. Complications were screw fracture(1 case), CSF leakage(1 case) in chip PLIF group and screw loosening and retropulsion of cage(1 case), CSF leakage(2 cases) in cage PLIF group. Conclusion : PLIF using cage is better than PLIF using autologous bone chips in the maintenance of intervertebral space height and fusion rate. But there is no statistical difference of the clinical outcomes between the two groups. Further studies, especially on long term follow-up, should be considered.

  • PDF

Application of Traditional Acupuncture on Canine Intervertebral Disc Disease (개에서 추간판 질환에 대한 침술치료 증례)

  • 정성목;박수원
    • Journal of Veterinary Clinics
    • /
    • v.21 no.1
    • /
    • pp.49-51
    • /
    • 2004
  • A four-year-old female Pekingese dog was presented with intermittent ambulatory hindlimb lameness and severe back pain. The course of the disease was acute and static and 5 days passed by until presentation. In neurological examination, severe back pain and slightly decreased proprioception in right hindlimb were shown. In radiographic examination, radiopacity was increased at T10-11 intervertebral disc space. According to the history taking, neurological examination and radiographic examination, it was tentatively diagnosed as intervertebral disc disease (IVDD). Conservative treatment was performed including cage rest, medication with prednisolone and traditional acupuncture. Acupoints were GV-6, GV-7, BL-18, BL-19. BL-40 and GB-34. Dry needlings rested for 20 minutes. Just after the first acupuncture treatment back pain was significantly decreased. With additional acupuncture treatment, all the clinical signs were not observed. It is considered that conservative therapy including traditional acupuncture, medication and cage rest might be the first choice of therapeutic method for Grade I or II IVDD in dogs.

Report for Correlation between the Measurement of Thoracic Kyphosis and the Herniation of Cervical Intervertebral Disc of Neck Pain Patients who Visit Korean Medicine Hospital (한방 병원에 경추 통증으로 내원한 환자들의 흉추부 만곡 및 경추부 추간판탈출증의 상관 관계에 관한 보고)

  • Choi, Young-Jun;Yoo, Su-Bin;Moon, Byung-Heon;Chung, Jai-Hyeon;Yun, Yeong-Ung;Kim, Kil-Hwan;Nam, Hang-Woo;Lee, Cha-Ro
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.10 no.1
    • /
    • pp.63-74
    • /
    • 2015
  • Objectives : This study is planned to classify correlation between thoracic kyphosis angle and prevalence of cervical intervertebral disc. Methods : We Measured the thoracic kyphosis angel of the 110 men and 179 women patients with neck pain in 00 Korean Medicine Hospital. We use Cobb's angle method and Thoracic cage dimension method for measuring the thoracic kyphosis. And We use Magentic Resonance Imaging(MRI) for classifying the patient who has cervical intervertebral disc or not. Results : 1. There was statistical difference on the thoracic cage dimension with gender(P<0.001), while there was no statistical difference on Cobb's angle with gender(P=0.882). 2. Age and thoracic cage dimension(r=0.383) is statistically more correlative than age and cobb's angle(r=-0.59). Conclusions : 1. Thoracic cage dimension and gender, Thoracic cage dimension and age were statistically concerned on patient who has neck pain, while Cobb's angle had no statistical correlation with age and gender. 2. There was no statistical difference on the Cobb's angle and Thoracic cage Dimension between patient who has one or more cervical disc herniation(Protrusion disc, Extrusion disc) segment and patient who didn't have cervical disc herniation(Protrusion disc, Extrusion disc) segment.