• Title/Summary/Keyword: interruption

Search Result 1,044, Processing Time 0.031 seconds

Interruption Cost Model of the Feeder Considering the Local Characteristics (지역 특성을 고려한 피더의 정전비용 모델)

  • Hwang, Won-Il;Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.22-28
    • /
    • 2007
  • This paper presents an interruption cost model of the feeder considering the local characteristics. KERI's survey results for the customers interruption cost are used through the research. Interruption cost of the feeder in a city is calculated in the ratio of customer's types. The customers consists of residencial, commercial, industrial and public type. The proposed method is applied to calculate interruption cost of the feeder in a small city and a metropolitan aria.

Evaluation for System Reliability taking into consideration Customer Interruption Cost (수용가 정전비용을 고려한 전력계통 공급신뢰도 평가)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Kim, Ho-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.133-135
    • /
    • 2002
  • It is raised for methodology to evaluate power system reliability using interruption cost which is converted customer loss due to interruption into cost according to power industry is rushed into competition appearance. This paper presents algorithms to evaluate reliability of distribution power system taking into consideration customer interruption cost. Customer interruption cost is considered as one of the valuable index to estimate reliability of the distribution power system from customer situation. Also. this paper estimate evaluation results regarding the reliability of distribution power system using a sample model system. Finally, evaluation results of unserved energy and system interruption cost based on customer interruption cost are shown in detail.

  • PDF

A Customer Interruption Cost Assessment Using Customer Survey (설문 조사방법을 이용한 수용가 정전비용 평가)

  • Chu, Cheol-Min;Lee, Byung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1787-1791
    • /
    • 2010
  • This paper presents the survey results of the interruption on domestic customer, especially commercial, with primary focus on the cost are presented. General method utilized in quantifying the benefit of reliability on power system is to estimate the Customer Interruption Cost(CIC) associated with the electric service interruption. According to change the circumstance of electricity market by the deregulation and the introduction of new technology, reliable and accurate CIC is required for estimate the applied plan and technology under the circumstance. This paper presents the commercial customer interruption cost is estimated by the survey conducted by KEPCO in 2009. To collect the customer interruption data for calculation of CIC, the survey is conducted. The survey targeting commercial customer around the branch-offices under twelve regional headquarters of KEPCO was carried out.

Customer Interruption Cost Assessment of Domestic Residential Customer Using Customer Survey (설문조사방법을 이용한 가정용 수용가 정전비용 평가)

  • Lee, Byung-Sung;Chu, Cheol-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1792-1796
    • /
    • 2010
  • In this paper, the survey results of the interruption on domestic residential customer with primary focus on the cost are presented. General method utilized in quantifying the benefit of reliability on power system is to estimate the Customer Interruption Cost(CIC) associated with the electric service interruption. According to change the circumstance of electricity market by the deregulation and the introduction of new technology, reliable and accurate CIC is required for estimate the applied plan and technology under the circumstance. This paper presents the residential customer interruption cost is estimated by the survey conducted by KEPCO in 2009. To collect the customer interruption data for calculation of CIC, the survey is conducted. The survey targeting residential customer around the branch-offices under twelve regional headquarters of KEPCO was carried out.

Evaluation of Interruption Costs for Commercial Customers

  • Choi Sang-Bong;Nam Kee-Young;Kim Dae-Kyeong;Jeong Seong-Hwan;Lee Jae-Duck;Rhoo Hee-Suk
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.56-61
    • /
    • 2005
  • This paper presents an evaluation of the interruption costs for commercial customers in Korea using customer survey methodology. When various research results are examined, the evaluation of direct interruption costs becomes much more simplified. Especially, in the case of commercial customers, it is known that the evaluation of direct interruption costs is more useful. Accordingly, this paper selected the customer survey method to evaluate the interruption costs for commercial customers in Korea considering interruption and customer characteristics.

Assessment of Reliability in the Distribution System of an Industrial Complex

  • Choi, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.201-207
    • /
    • 2007
  • As the power industry moves towards open competition, there has been a need for methodology to evaluate distribution power system reliability by using customer interruption costs, particularly in power supply zones under the competitive electricity market. This paper presents an algorithm to evaluate system average interruption duration index, expected energy not supplied, and system outage cost taking into consideration failure rate of the distribution facility and industrial customer interruption cost. Also, to apply this algorithm to evaluate system outage cost presented in this paper, the distribution arrangement of a dual supply system consisting of mostly high voltage customers in an industrial complex in Korea is used as a sample case study. Finally, evaluation results of system interruption cost, system average interruption duration index, and expected energy not supplied in the sample industrial complex area are shown in detail.

A Survey Study on the Assessment of Customer Interruption Costs Using Macro Economic Methodology in Korea

  • Park, Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.6-10
    • /
    • 2004
  • This paper presents an assessment of the customer interruption costs using a macro economic methodology of Korean customers by cities and provinces. The customer interruption cost is considered a very useful index in quantifying reliability worth from a customer point of view. This paper reviews the methodology to evaluate the customer interruption costs and ratio to the average revenues per electric energy sold for public, service agriculture, fishery, mining, manufacturing and residential sectors by cities and provinces in Korea.

Optical Properties of InAs Quantum Dots Grown by Using Indium Interruption Growth Technique (Indium Interruption Growth법으로 성장한 InAs 양자점의 광학적 특성)

  • Lee, Hi-Jong;Ryu, Mee-Yi;Kim, Jin-Soo
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.474-480
    • /
    • 2009
  • We have investigated optical properties of InAs quantum dots (QDs) grown on GaAs (100) substrate by molecular beam epitaxy, by means of photoluminescence (PL) and time-resolved PL spectroscopy. InAs QDs were grown by using In interruption growth technique, in which the In flux was periodically interrupted by a closed In shutter during InAs QDs growth. The shutter of In source was opened for 1 s and then closed for 0, 9, 19, 29, or 39 s. This growth sequence was repeated 30 times during QDs growth. For each sample, the total amount of In contributing to the growth was the same (30 s) but total growth time was varied during the InAs growth. As the In interruption time is increased from 0 to 19 s, the PL peak position of the QDs is red-shifted from 1096 to 1198 nm, and the PL intensity is increased. However, the PL peak is unchanged and the intensity is decreased as the In interruption time is increased further to 39 s. The PL decay times measured at the PL peak position for all the InAs QDs are independent on the QD growth conditions and showed about 1 ns. The red-shift of PL peak and the increase of PL intensity can be explained due to increased QD size and the enhancement in the migration of In atoms using In interruption technique. These results indicated that the size and shape of InAs QDs can be controlled by using In interruption growth technique. Thus the emission wavelength of the InAs QDs on GaAs substrate can also be controlled.

PD Localization by Metal Sheath Interruption Methods for Power Cable and Accessories (차폐분리에 의한 전력케이블 및 접속함의 부분방전 위치 검출)

  • Lee, Chang-Yeong;Sin, Du-Seong;Kim, Chung-Sik;Kim, Dong-Uk;Park, Wan-Gi
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.3
    • /
    • pp.196-201
    • /
    • 2000
  • It is very important not only to detect PD signal but also to locate PD source in power cable line including its accessories. In this paper, the PID localization technique using interruption of metal sheath of cable or accessory is described. By interruption of metal sheath, the polarity of PD pulse to be measured on each part can be compared. With this technique, the exact location of PD in the accessory which has some defects can be found. Although the 'Soft' interruption method, that is, cable sheath is divided by semi-conductive layer with the resistance of higher than 1 k$\Omega$, was used instead of 'Hard' interruption method, it is also possible to detect exact location of PD. This technique is considered to be very effective for detecting PD localization in the type test of cable and accessories.

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.