• Title/Summary/Keyword: interruption

Search Result 1,044, Processing Time 0.039 seconds

A longitudinal analysis on interruption in preschool children who stutter during interactions with their mothers (학령전 말더듬아동과 어머니 간 상호작용 시 끼어들기 특성 종단적 분석)

  • Kwak, Hyo-Jung;Hwang, Si-Hyeon;Song, Pu-Reum;Sim, Hyun-Sub;Lee, Soo-Bok
    • Phonetics and Speech Sciences
    • /
    • v.13 no.4
    • /
    • pp.75-87
    • /
    • 2021
  • The purpose of this study was to investigate, longitudinally, interruption behavior which children who do stutter (CWS), children who do not stutter (CWNS) and their mothers and relationship with disfluency of children showed during interactions with their mothers. Subjects for this study consisted of 2-5 year old CWS (male 2 and female 4), an age-matched group of CWNS (male 3 and female 3), and their mothers. Frequencies of normal disfluency (ND) and abnormal disfluency (AD) in children group and frequency of interruption and simultalk duration in children and mothers group were measured two times (initial visit and 12 months later) over the course of one year. As a result, no significant difference was observed in frequency of interruption and simultalk duration both between two mother groups and between two child groups at initial visit and 12 months later. However, frequency of interruption increased significantly over the course of one year in CWS group. A significant group difference was found in frequency of interruption of mothers but, no significant difference was observed in simultalk duration of mothers at initial visit. In the CWS·mothers group, no factors were related with disfluency of children at initial visit and 12 months later. These findings suggest that interruption is not just negative behavior, and that reducing interruption should be considered in child·parent interaction therapy for CWS.

Questionnaire Development and Survey & Analysis for the Calculation of the Domestic Industrial Customer Interruption Costs (산업수용가의 정전비용 산출을 위한 조사 분석 연구)

  • 박충열;남기영;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.165-170
    • /
    • 2004
  • This paper presents summary results of direct interview survey of Korean industrial customers conducted to evaluate the direct and short duration interruption costs resulting from local random electrical supply interruptions. The cost is evaluated using the questionnaires authors designed, which are mainly on the experience or preparatory actions consumers predicted they would take. Economic evaluation of reliability that traditionally takes into account duration and frequency of interruption does not accurately reflect the lost value or economic impacts of industrial customer, especially large size, caused by any kind of interruption. So, to imply the substantial difference in costs incurred by different customer group, the authors apply the international standards, i.e. IEC, IEEE, to the analysis on the interruption costs.

An Analysis of Cold Gas Flow-Field for UHV Class Interrupters (초고압 가스차단부의 냉가스 유동해석)

  • Song, Gi-Dong;Park, Gyeong-Yeop;Song, Won-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.387-394
    • /
    • 2000
  • This paper presents a method of cold gas flow-field analysis within puffer type GCB(Gas Circuit Breaker). Using this method, the entire interruption process including opening operation of GCB can be simulated successfully. In particular, the distortion problem of the grid due to the movement of moving parts can be dealt with by the fixed grid technique. The gas parameters such as temperature, pressure, density, velocity through the entire interruption process can be calculated and visualized. It was confirmed that the time variation of pressure which was calculated from the application of the method to a model GCB agreed with the experimental one. Therefore it is possible to evaluate the small current interruption capability analytically and to design the interrupter which has excellent interruption capability using the proposed method. It is expected that the proposed method can reduce the time and cost for development of GCB very much. It also will be possible to develop the hot-gas flow-field analysis program by combining the cold-gas flow field program with the arc model and to evaluate the large current interruption capability.

  • PDF

Estimation of Interruption Capability of a Serial-Hybrid Type Model Gas Circuit Breaker (직렬-복합소호형 모델 가스차단기의 차단성능평가)

  • 송기동;정진교;박경엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.538-544
    • /
    • 2004
  • This paper presents the interruption capability of serial-hybrid type GCB (gas circuit breaker) compared with that of puffer type. First a puffer type model interrupter which has the stroke length of 80 mm has been designed and manufactured. And also, a serial-hybrid type interrupter which has the same design parameters as the puffer type interrupter except the serially arranged thermal-expansion chamber and puffer cylinder has been fabricated. Using a simplified synthetic test facility, the critical interruption capabilities of the two GCBs have been estimated. The critical di/dt, the critical dV/dt of ITRV (initial transient recovery voltage) and the minimum arcing time of the puffer type model GCB were 10.7 A/${\mu}\textrm{s}$, 5.5 kV/${\mu}\textrm{s}$, and 15.0 ms respectively. In the case of serial-hybrid type model GCB, each of the values was 16.6A/${\mu}\textrm{s}$, 11.5 kV/${\mu}\textrm{s}$ and 13.0 ms. As a conclusion of this work, it has been quantitatively confirmed that the hybrid type interrupter can obtain the sufficient interruption capability at the operating force which is so low that puffer type interrupter has not the interruption capability.

A Survey on the interruption costs for the sensitive industrial customers to the short duration interruption (순간정전에 민감한 산업수용가의 정전비용에 관한 조사연구)

  • Nam, Kee-Young;Choi, Sang-Bong;Ryoo, Hee-Suk;Lee, Jae-Duck;Jeong, Seong-Hwan;Kim, Dae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.90-92
    • /
    • 2005
  • This paper addresses the analysis of interruption costs and the studies made through the direct interview with Korean Industrial customers for the period of two years. It is conducted to evaluate the direct and short duration interruption costs resulting from local random electrical supply interruptions. The cost is evaluated by providing a designed questionnaire focused on the experience or the preparative actions which consumers predicted they would take. In the first phase, authors made a survey on all types of industry with 176 industrial customers and evaluated them as per standard industry classification (SIC). In that case, the evaluation data obtained are not so reasonable, because the number of sampled industries was small and the sampled industries were surveyed by being divided into 18 types. So, in the second phase the authors concentrated on only 4 types of 302 industries who have many and large sensitive loads to the short duration interruption.

  • PDF

Reliability Improvement Considering Effect of Dispersed Generator and Interruption Cost in Distribution Systems (분산전원의 영향과 정전비용을 고려한 신뢰도 향상)

  • Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.172-177
    • /
    • 2006
  • This paper presents a method to improve reliability considering dispersed generator(DG) installation and interruption cost with load types. It is used to the different interruption costs with load pattern of daily peak load. The objective functions such as power losses cost operation cost of DG, power buy cost and interruption cost are minimized for reliability improvement and efficient operation. The several indices for reliability evaluation are improved by dispersed generator installation. The proposed method is applied to IEEE 13 bus test systems to demonstrate its effectiveness.

Evaluation Method I of the Small Current Breaking Performance for SF(sub)6-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$ 가스차단기의 소전류 차단성능 해석기술 I)

  • 송기동;이병운;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.331-337
    • /
    • 2001
  • With the increasing reliability of analysis schemes and the dramatically increased calculating speed, the computer simulation has become and indispensable process to predict the interruption capacity of circuit breakers. Generally, circuit breakers have to possess both the small current and large current interruption abilities and the circuit breaker designers need to evaluate its capacities to save the time and the expense. The analysis of small current and the large current interruption performances have been considered separately because the phenomena occurring in a interrupter are quite different. To analyze the dielectric recovery after large current interruption many physical phenomena such as heat transfer, convection and arc radiation, the nozzle ablation, the ionization of high temperature SF(sub)6 gas, the electric and themagnetic forces and so forth mush be considered. However, in the analysis of small current interruption performance only the cold gas flow analysis needs to be carried out because the capacitive current is to small that the influence from the current can be neglected. In this paper, an empirical equation which is obtained from a series of tests to estimate the dielectric recovery strength has been applied to a real circuit breaker. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

Optical Properties of InAs Quantum Dots Grown by Using Arsenic Interruption Technique

  • Choe, Yun-Ho;Kim, Hui-Yeon;Ryu, Mi-Lee;Jo, Byeong-Gu;Kim, Jin-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.268-268
    • /
    • 2011
  • GaAs (001) 기판에 MBE를 이용하여 자발형성법으로 성장한 InAs 양자점(QDs: quantum dots)의 광학적 특성을 PL (photoluminescence)과 TRPL (time-resolved PL)을 이용하여 분석하였다. InAs 양자점 성장 동안 In 공급은 계속하면서 As 공급을 주기적으로 차단과 공급을 반복하면서 성장하였다. As 차단과 공급을 1초, 2초, 그리고 3초씩 하면서 InAs 양자점을 성장하였다. 기준시료는 In과 As 공급을 중단하지 않고 20초 동안 성장하였다. As interruption mode로 성장한 시료들의 QD density는 기준시료에 비해 증가하였으며, size distribution도 기준시료에 비해 향상되었다. 기준시료와 비교하였을 때, As interruption mode로 성장한 시료들의 PL 피크는 적색이동 (red-shift)를 보였으며, PL 세기는 2배 이상 증가하였다. PL 소멸곡선은 파장이 증가함에 따라 점차 느려지다가 PL 피크에서 가장 느린 소멸을 보인 후 다시 점차 빠르게 소멸하였다. 시료의 온도를 10 K에서 60 K까지 증가하였을 때 PL 피크 에너지는 변하지 않았으며, PL 소멸시간은 서서히 증가함을 보였다. 온도를 더 증가하였을 때 PL 피크 에너지는 적색이동 하였으며 PL 소멸시간도 빠르게 감소함을 보였다. As interruption mode로 성장한 양자점 시료의 구조적 특성 변화에 의한 광학적 특성 변화를 확인하였다.

  • PDF

The Investment Scheme of the Maintenance Planning with Limited Investment Budget in the Distribution Systems for Minimizing the Interruption Cost (제한된 투자 예산으로 정전비용 최소화를 위한 배전계통 유지보수 계획의 투자 방안)

  • Hwang, Won-Il;Kim, Kyu-Ho;Kim, Hong-Rae;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.1-7
    • /
    • 2010
  • The reliability of a power system has close relationship with the maintenance of the distribution systems. This paper presents the method of the maintenance planning of the distribution systems by minimizing the interruption cost. The interruption cost for the equipment failures is formulated using time varying failure rate and minimized by optimization of the object function. The proposed method provides the priority list for the investment of the maintenance subject to the limited investment budget by the economic analysis. In order to test the proposed method, the modified distribution system of a rural area is introduced for the testing system. Test results show that the proposed method is good enough by evaluating the improvement of the reliability of the power system.

Making Decision of the Maintenance Priority of Power Distribution System using Time Varying Failure Rate and Interruption Cost

  • Chu, Cheol-Min;Kim, Jae-Chul;Yun, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • The purpose of the this paper is to make decision of the maintenance priority of power distribution system using Time-Varying Failure Rate(TVFR) with interruption cost. This paper emphasizes the practical use of the reliability indices and interruption cost. To make a decision of maintenance priority on power distribution system equipment, the quantification of the reliability level should be represented as a cost. In this paper, the TVFR of power distribution system equipment applied in this paper utilizes analytic method to use the historical data of KEPCO. From this result, the sensitivity analysis on TVFR of equipment was done for the priority, which represents that high priority of the equipment has more effect on system reliability, such as SAIDI or SAIFI, than other equipment. By this priority, the investment plan is established. In this result, customer interruption cost(CIC) could be extracted, and CIC is used as weighting factor to consider a importance of customer. After that, the result calculated the proposal method in this paper is compared with other priority method, such as lifetime, failure rate or only sensitivity.