• Title/Summary/Keyword: interruption

Search Result 1,044, Processing Time 0.036 seconds

Comparison of Small Current Interruption Capability Depending on the Type of Interrupter (차단부 형태에 따른 소전류 차단성능 비교)

  • Song, Ki-Dong;Chong, Jin-Kyo;Kim, Hong-Kyu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.7
    • /
    • pp.362-368
    • /
    • 2006
  • This paper presents the results of a small capacitive current interruption test for the three types of interrupter which are called 'serial type', 'parallel/separated type' and 'puffer type' according to the arrangement of the thermal expansion chamber and the puffer cylinder. After the preconditioning test the small current interruption capability of the 'puffer type' decreased, on the contrary, that of the hybrid interrupters increased. A number of reignition have been occurred in the 'serial type' hybrid interrupter and the change of small current interruption capability after preconditioning test is mainly influenced by the structure of interrupter. Finally it has been proved that the 'parallel/separated type' hybrid interrupter has the best interruption performance through the verification tests.

Assessment of Interruption Costs by Industrial Customer Type

  • Choi, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.448-454
    • /
    • 2006
  • As the power industry moves towards open competition, a need has arisen for appropriate methodology to evaluate power system reliability by using customer Interruption costs. This paper presents an assessment of the interruption costs by industrial customer type in Korea using customer survey methodology. When various research results are examined, the customer damage survey methodology becomes much more generalized. Especially, in the case of industrial customers, it is known that evaluation by the customer damage survey is more useful. Accordingly, this paper selected the customer damage survey method to evaluate the interruption costs by industrial customer type in Korea considering interruption and customer characteristics.

Survey & Analysis for the Calculation on the Industrial Customer Interruption Costs (산업용 수용가의 정전비용 산출을 위한 조사 분석(I))

  • Nam, K.Y.;Choi, S.B.;Ryoo, H.S.;Jeong, S.H.;Lee, J.D.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.122-124
    • /
    • 2003
  • In recent, the various electric & electronic machines are newly developed everyday and the electricity supply system & environment on the process from generation to consumption of electricity also is being changed. In other words, both supplier and consumer of electricity are required to be responsible for their interruption costs. So, it is very important and meaningful work for evaluating the interruption costs in quantitative. Additionally, since the restructuring of electric industry is on going in world wide, after restructuring, most of all electric utilities and consumer have to consider the supply reliability and quality as a important element of the calculating the related costs and contract because it takes costs to keep the supply reliability and quality highly. Especially, the interruption or the supply reliability will have influence on the bilateral contract between supplier and customer as a key point to determine the once in competitive electric market. Therefore, it has very important moaning to calculate the interruption costs in the present that it is prepared to open the competitive electric market. In this paper, international standards, i.e. IEC, IEEE, are applied to the analysis on the interruption costs used in the questionnaires which are newly designed including short duration interruption by the authors instead of traditional interruption criteria. Firstly, using the questionnaires, the authors got related data from industries according to the standard industry classification which are being used in electric utility and other national statistics in Korea. However, analysis results are hard to say typical value because of the not so many samples. So, the authors are going to survey and focus on not all kinds of industry but a few kinds of them that their facilities are effected or stop by short duration interruptions, so there are large economical damages. Finally, the authors hope to find the reliable and meaningful model in interruption costs of industrial customer.

  • PDF

Research for the survey of method to serviced customer Interruption cost evaluation (전력수용가 정전비용 산출물 위한 설문조사 방법론에 관한 연구)

  • Park, Soo-Man;Kim, Jae-Chul;Moon, Jong-Fil;Bae, Ju-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.259-261
    • /
    • 2002
  • KEPCO(Korea Electric Power Corporation) has been management alone before some time. However through the electrical industry reorganization generation and KPX(Korea Power Exchange) were separated on 2001. A marketing and distribution part will be separated in the future. While many problem for appear in future. how to management for power system network is important. unfortunallity, electrical power industry is starting point right now. Thus, detail data is incomplete for this field and detail research for this field is required with distribution reorganazation. In this paper suggest for customer interruption cost compute method to establish a standard. The standard is need to security operation of power system network. The customer interruption cost compute method necessity of customer interruption cost compute method is minimizing process for total cost. As final total cost compute through the interruption cost compute, we can recognize investment point exactly. We cited foreign survey questions, because exactly matched survey questions for in the country circumstance is not exist. And process to survey performance suggest after modify for match in the country circumstance. Survey questions that suggested fer this paper are classified five categories. This paper suggests to detail survey questions and survey method before survey and suggest to how to customer interruption compute when survey data is ensured. Moreover this paper suggest to average interruption cost compute for residential customer using statistical method.

  • PDF

Power Interruption Cost Calculation based on Value-based Methodology (가치평가법을 사용한 정전관련비용의 산정)

  • Lee, Buhm;Kim, Kyoung-Min;Choi, Nam-Sup
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.293-300
    • /
    • 2021
  • This study presents a Power Quality(:PQ) costs calculation methodology based on Value-Based Methodology. A SCDF including Voltage Sag Costs is presented to calculate Sustained Interruption Costs, Momentary Interruption Costs, and Voltage Sags Costs. Authors compared between interruption costs without Back-Up Power Supply and interruption costs with Back-Up Power Supply, and showed reduction of interruption costs by investing Back-UP Power Supply by multi-lateral analyzation. By applying this method to the real system, evaluated and analyzed power quality of the system.

Reasons, Incidences, and Influencing Factors of Work Interruptions in Intensive Care Unit Nurses (중환자실 간호사에게 발생하는 업무 흐름 중단 이유와 발생빈도 및 영향요인)

  • You, Jung Eun;Lee, Eun Nam
    • Journal of muscle and joint health
    • /
    • v.27 no.3
    • /
    • pp.247-254
    • /
    • 2020
  • Purpose: This was a descriptive observational study examining the reasons for, frequency of, and factors affecting work interruption among intensive care unit (ICU) nurses. Methods: Convenience sampling was used to recruit 46 regular nurses who had been working in an ICU at D tertiary hospital in B metropolitan city for at least six months. To measure the degree of work interruption, this study revised a tool used by Brixey et al. (2007) for analyzing the type of work interruption. Results: A total of 1,787 work interruptions occurred during 368 hours of observation, i.e., at an average of 4.85 times per hour. Communication-related factors caused work interruption most frequently, followed by environmental, work-related, and personal factors. As for the work-related characteristics of nurses, participants experienced work interruption more frequently while working on weekdays, when the medical staff were stationed, than on weekends. Conclusion: ICU nurses experienced work interruption frequently. With the health care system expected to become more complicated in the future, efforts should be made to reduce unnecessary work interruptions to improve the operation efficiency of ICUs.

Evaluation of Interruption Cost for Determination of Optimal Reliability Level (최적 공급신뢰도 레벨 결정을 위한 정전비용의 평가)

  • Choi, Sang-Bong;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Kim, Ho-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.204-206
    • /
    • 2001
  • This paper presents methodology to evaluate interruption cost for determination of optimal reliability level. Recently, the power interruption cost is considered one of the useful index to determine optimal reliability level. Accordingly, in this paper reports estimation results of customer interruption cost to determine optimal reliability level by the economic macro method based on the 5 years from 1995 to 1999 and various kinds of customers in Korea.

  • PDF

The Life Course Events and the Career Interruption among Korean Women (여성의 경력단절 기간별 생애사건 효과분석)

  • Min, Hyun-Joo
    • Korea journal of population studies
    • /
    • v.34 no.1
    • /
    • pp.53-72
    • /
    • 2011
  • This study analyzes the effects of life course events and labor market conditions on the duration of career interruption among Korean women. The data were drawn from 'A Survey on the Women's Employment Interruption in Korea' conducted by the Korean Ministry of Gender Equality in 2009(currently the Korean Ministry of Gender Equality and Family). This study categorizes the duration of career interruption into three categories: (1) short term interruption(less than 12months), (2) short-medium term interruptio(12-35 months), (3) intermediate term interruption(36-59 months), (4) long term interruption(longer than 36 months), and then analyzes how demographic factors, labor market condition, and life events shape the timing of re-entry into the labor market among women. According to the findings, the jobs that are conducive to combining market work and mother's role expedite women's return to the labor market. Further, the younger, higher the level of human capital, and higher monthly wages that women earned before leaving the labor market, women are likely to experience short-term interruption(less than 12 months) rather than long-term interruption(longer than 60 months). Women who left from the labor market to care for kids are also likely to return to the labor market. However, women who have preschoolers are likely to experience long-term career interruption. These findings highlight the role of family supportive culture at the workplace in order for women to continue their employment while intensive family formation period. Furthermore, the finding that the discriminatory practices against women, in particular mother workers at the workplace lead women to exit from the market work calls for attention to establish family friendly workplace.

Flowering Response to Light Intensity and Night Interruption in Perilla (광강도와 야간조명에 따른 들깨의 개화 반응)

  • Oh, Myung-Kyu;Yu, Sug-Jong;Kim, Jong-Tae;Oh, Youn-Sup;Cheong, Young-Keun;Jang, Young-Sun;Park, Inn-Jin;Park, Keun-Yong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.5
    • /
    • pp.543-547
    • /
    • 1995
  • This study was conducted to light intensity and night interruption on leaf production in perilla. Using two cultivars ; og-dong and Yeup-sil. The present studies were conducted to investigate effect of the light intensity and night interruption for prolongation of vegetative growth by flowering inhibition in the National Honam Crop Experiment Station, R. D. A, Iri, Korea. The results are summarized as followes, varietal differences of days to flower initiation were not significant by the light intensity and night interruption, however differences of days to flower initiation light intensity or night interruption treatment were higly significant. Flowering of perilla was prolongated in high light intensity and in long night interruption. Between the factors treated flowering of perilla was more influenced by light intensity than night interruption. Days to flower initiation of perilla were light intensity(0.5∼1 Lux) in 30 mins night interruption, however 3∼10 light intensity in 60 mins night interruption and 30∼100 Lux light intensity in 10, 30, 60 mins night interruption treatment were not flowering. Plant height, leaf area and dry weight of perilla were the highest in 30∼100 Lux light intensity treatment than in the other treatments. The results would be avaliable establish year-round production methods for low cost of perilla leaf.

  • PDF

Growth Interruption Effects of GaAs/AlGaAs Quantum Wells Grown by Molecular Beam Epitaxy (분자선에피택시에 의해 성장한 GaAs/AlGaAs 양자우물의 성장 멈춤 효과)

  • Kim, Min-Su;Leem, Jae-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.365-370
    • /
    • 2010
  • The growth interruption effects on growth mode of the GaAs and AlGaAs epitaxial layers grown on GaAs substrate by molecular beam epitaxy were investigated. Growth process of the epitaxial layers as a function of the growth interruption time was observed by reflection high energy electron diffraction (RHEED). The growth interruption time was 0, 15, 30, 60 s. The GaAs/$Al_{0.3}Ga_{0.7}As$ multi quantum wells (MQWs) with different growth interruption time were grown and its properties were investigated. RHEED intensity oscillation and optical property of the MQWs were dependent on the growth interruption time. When the growth interruption time was 30 s, interface between the well and barrier layers became sharper.