• Title/Summary/Keyword: interocclusal record

Search Result 11, Processing Time 0.024 seconds

A COMPARATIVE STUDY ON THE RECORDINGS OF MANDIBULAR MOVEMENT (운동의 기록방법에 관한 비교 연구)

  • Shin, Sang Yong;Kim, Kwang Nam;Chang, Ik Tai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.125-146
    • /
    • 1990
  • The relationale for recording mandibular movement is to accurately adjust an articulator. Techniques to record mandibular movement include radiographic interpretation, extraoral tracing, and intraoral recording materials. This study was performed to compare the concylar guidance inclination and Bennett shift(immediate & progressive side shift)obtained by using an electronic pantograph, pantograph and wax interocclusal records in Korean. Ten adults who have normal occlusion and are free of TMJ dysfunction were selected and clutches were constructed. At first Pantronic survey was performed three times by using an kinematic hinge axis according to manufacturer's direction. Next pantographic survey was performed three times and the articulator was adjusted with each pantographic recording. And then maxillary cast was attached to the articulator with pantographic as a face-bow and the mandibular cast was mounted to the articulator with centric relation record. Three protrusive, three left lateral and three right lateral wax interocclusal records were taken on the subjects and the articulator was adjusted with each interocclusal record. Protrusive condylar inclination, lateral condylar inclination, immediate side shift and progressive side shift obtained by using electronic pantograph, pantograph and wax interocclusal record were compared and analized. The results were as follows; 1. The average left and right protrusive and orbiting condylar inclination($33.7^{\circ},\;37.1^{\circ},\;40.6^{\circ},\;43.5^{\circ}$) record with Pantronic was significantly greater than that recorded with other methods. 2. The average left and right protrusive and orbiting condylar inclination($24.8^{\circ},\;27.0^{\circ},\;31.4^{\circ},\;32.4^{\circ}$)recorded with wax interocclusal record was less than that of other methods. 3. The average left and right immediate side shift(0.57mm,0.44mm)recorded with wax interocclusal record was greater than that of other methods and the average left rigtht immmediate side shift(0.30mm,0.41mm)recorded with Pantronic was significantly greater than that recorded with pantograph(0.11mm,0.20mm). 4. The average variance of wax interocclusal was signivicantly higher than that of other methods.

  • PDF

ACCURACY OF FOUR ELASTOMERIC INTEROCCLUSAL RECORDING MATERIALS (수종 고무 교합인기 재료의 정확성에 관한 연구)

  • Bae, Jeong-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.355-365
    • /
    • 1998
  • The purpose of this study is to evaluate the accuracy of four elastomeric interocclusal recording materials and the weight change according to different storage period (24 hours, 48hours, 7days) and different conditions (dry, wet). The techniques for establishing the intercuspal position were centic occlusion interocclusal record with four elastomeric interocclusal recording materials (Ramitec, Stat-BR, Blu-Mousse, Regisil) (experimental groups) and location of the cast in a position of maximum in-terdigitation using tactile and visual method(control group). To evaluate the accuracy of four elastomeric interocclusal recording materials, the quality of contacts between the mounted casts was compared with the results of an occlusal examination of the same subjects. The results were as follows : 1. The most accurate method of articulating study casts at the intercuspal position was by hand articulation and no significant differences in accuracy were observerd among the experimental groups. 2. In case of interocclusal records storaged in dry sealed plastic box, no significant differences in accuracy were observed among the experimental groups. 3. In case of interocclusal records storaged in water, there was significant inaccuracy in Ramitec group. 4. The biggest weight change was observed in Ramitec group in all storage conditions

  • PDF

A useful method of using the healing abutments for interocclusal records in implant overdenture: a case report

  • Choi, Hyunsuk;Kang, Sohee
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.4
    • /
    • pp.341-343
    • /
    • 2022
  • To determine the vertical dimension and centric relation during the construction of implant overdentures, the record base and wax rim may need to be adjusted. The conventional method has several drawbacks, as it requires repeated tightening and loosening of the impression coping. Here, we report a useful and novel method for interocclusal records using the healing abutments in implant overdentures. Our case demonstrates that this method is easier and simpler and prevents gingival collapse.

Accuracy comparison of buccal bite scans by five intra-oral scanners (구강스캐너 5종의 협측 악간관계 스캔 정확성 비교 연구)

  • Park, Ji-Man;Jeon, Jin;Heo, Seong-Joo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.17-31
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the accuracy of the interocclusal relationship between upper and lower teeth according to the buccal interocclusal record scan using various intraoral scanner systems. Materials and Methods: The upper and lower full arch Models with normal occlusion were scanned with 5 intraoral scanners (Cerec Omnicam, CS3500, iTero, Trios, True Definition). Buccal interocclusal record scan was taken only at the left side while occlusion was intentionally raised by 1 mm, 2 mm, 3 mm, and 4 mm with metal cylinder core embedded within polyvinylsiloxane bite registration material at the right molar region. The superimposition analysis was done to evaluate overall three-dimensional deviation and cross-section analysis was done to evaluate the degree and the direction of deviation of interocclusal relationship. Results: From the superimposition study, Cerec Omnicam showed the least deviation ($165.5{\mu}m$) and CS3500 ($369.0{\mu}m$) showed the largest (P < 0.01). And the deviation was greater in 3, 4, 2 mm group than 1 mm (P < 0.01). From the cross-section study, Cerec Omnicam showed the farthest deviation ($-242.8{\mu}m$) and CS3500 showed the closest deviation ($312.5{\mu}m$) and a significantly high value was shown in 3 mm group. Conclusion: Every intraoral scanner has different accuracy in reproducing interocclusal relationship.

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

A comparative study to measure the condylar guidance by the radiographic and clinical methods

  • Shreshta, Pragya;Jain, Veena;Bhalla, Ashu;Pruthi, Gunjan
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.153-157
    • /
    • 2012
  • PURPOSE. The study was conducted to compare the radiographic and clinical methods of measuring the horizontal condylar guidance (HCG) values. MATERIALS AND METHODS. The condylar guidance was measured using the radiographic (CT scan) and three clinical methods i.e. the wax protrusive records, Lucia jig record and intraoral central bearing device in 12 patients aged between 20-40 years irrespective of sex. The records were taken and transferred on the semi-adjustable articulator to record the HCG values. The CT scan was taken for 3D reconstruction of the mid facial region. Frankfort horizontal plane (FHP) and a line extending from the superior anterior most point on the glenoid fossa to the most convex point on the apex of articular eminence (AE) was marked on the CT scan. An angle between these two lines was measured on both right and left sides to obtain condylar inclination angle. Three interocclusal protrusive wax and jig records were taken and transferred to the semi adjustable articulator. Three readings were recorded on each side. Similarly the records were taken and transferred to the same articulator using the intra oral central bearing device to record the readings. RESULTS. The statistical analysis showed insignificant differences in the HCG values between the right and left sides [(P=.589 (CT), P=.928 (wax), P=.625 (jig), P=.886 (tracer)]. The clinical methods provided low Pearsons correlation values [(R = 0.423 (wax), R = 0.354 (jig), R = 0.265 (tracer)] for the right as well as the left sides when compared with the CT values. Among the clinical methods, jig and wax method showed strong level of association which is statistically significant while the intra-oral tracer showed weak association with the other two methods. CONCLUSION. The right and left HCG values were almost similar. The CT scan showed higher HCG values than the clinical methods and among the clinical methods, values obtained from all the methods were comparable.

Relation of head posture and occlusal contact area using photo occlusion analysis (광조사교합분석법을 이용한 머리 위치와 교합접촉면적의 관계)

  • Kim, Chang-Hwan;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.90-97
    • /
    • 2019
  • Purpose: Previous studies related with occlusal contact area were limited that interocclusal thickness level or the method of measurement has not been accurate in measuring. The purpose of this study was to investigate the relation between head posture and occlusal contact area using photo occlusion analysis. Materials and Methods: 54 subjects with complete dentition (44 men, 10 women / 23 to 33 years of age) were included. To identify the relationship between head posture and occlusal contact area, subjects took interocclusal record in maximal intercuspal position with three different positions(supine position ($0^{\circ}$) / inclined position ($45^{\circ}$) / upright position ($90^{\circ}$)) on the dental unit chair. Occlusal contact area was analyzed using photo occlusion analysis. Statistical analyses were performed with SPSS ver.25.0 at 95% confidence interval. Results: Head posture has no significant effect on the changes of occlusal contact area (P > 0.05). Conclusion: When interocclusal relation is stable, head posture does not change a interocclusal record because head posture has no significant effect on occlusal contact area. Analysis of occlusal contact area using photo occlsion analysis device is useful due to its material property and simplicity.

Fabrication of complete dentures by conventional method and CAD/CAM milling: A case report (전통적 방식과 CAD/CAM을 이용한 양악 총의치 수복 증례)

  • Jung, Youngchul;Lee, Junsuk;Hong, Seoung-Jin;Noh, Kwantae;Kim, Hyeong-Seob;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.296-303
    • /
    • 2019
  • In edentulous patient, not only mastication and pronunciation but also esthetics are compromised. By restoring an edentulous patient with complete dentures, masticatory function and esthetics can be rehabilitated. The advantages of the dentures using CAD/CAM are that they can be reconstructed ubiquitously with stored data, and the strength and density of CAD/CAM material are clinically acceptable. In this clinical report, interocclusal record was taken in a conventional manner and then two lab processing procedures were performed: conventional method and CAD/CAM method. Two types of processing procedures were compared and evaluated. Fair clinical results were obtained in both ways, satisfying the patient.

Correlation between sagittal condylar guidance angles obtained using radiographic and protrusive occlusal record methods

  • Kwon, Oh-Kyun;Yang, Seung-Won;Kim, Jee-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.302-307
    • /
    • 2017
  • PURPOSE. This study compared the SCGAs measured in three types of radiographic images (panoramic, CBCT panoramic-section, and CBCT cross-section images) with values measured using the protrusive occlusal record. MATERIALS AND METHODS. SCGAs were measured in 20 patients on a semi-adjustable articulator using the protrusive interocclusal record. Panoramic and CBCT images were obtained. SCGAs were measured on CBCT images in panoramic and cross sections. In all of the radiographic images, SCGAs were measured using the Frankfort horizontal reference line and the mean curvature line. The most-superior and most-inferior points of the curvatures were identified to determine the mean curvature line. Each measurement was performed twice by two operators independently. The data were analyzed by the t-test, Pearson's correlation test, and Cronbach's ${\alpha}$ using SPSS (${\alpha}=.05$). RESULTS. The mean right and left SCGAs were as follows: protrusive occlusal record (30.1 and 30.2 degrees, respectively), panoramic (38.9 and 38.7 degrees), CBCT panoramic sections (35.4 and 36.8 degrees), and CBCT cross sections (35.3 and 36.1 degrees). The SCGAs differed significantly among the groups. The Pearson coefficients for the correlations with the protrusive occlusal record measurements on the left and right sides were as follows: panoramic (0.834 and 0.791, respectively), CBCT panoramic-section (0.918 and 0.837), and CBCT cross-section (0.918 and 0.845) images. CONCLUSION. Strong correlations were found between SCGAs obtained using radiographic images and the protrusive occlusal record.

A STUDY ON THE DIFFERENCE OF THE SAGITTAL CONDYLAR GUIDANCES BY MEASURING METHODS (측정방법에 따른 시상과로 경사각의 차이에 관한 연구)

  • Lew, Jin-Young;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.77-86
    • /
    • 1993
  • The purpose of this study was to compare the sagittal condylar guidance obtained by the graphic method(pantographic tracing) with that produced by the positional method(check-bite). Ten adults who had normal occlusion and were free of TMJ dysfunction were selected, and the clutches were constructed. At first pantographic survey was performed and the articulator was adjusted with each pantographic recording. And then three protrusive check-bite were taken on the subjects using the polyether$(Lamitec^{(R)})$ on the buccal side of the posterior teeth without the interocclusal record method and the vericheck method was performed with each protrusive check-bite. Sagittal condylar guidances obtained by using the pantograph and Vericheck were compared and analyzed statistically. The results were as follows: 1. The average condylar guidance ankle at 4mm and 7mm from centric relation point on the pantograph $(35.9{\pm}1.10^{\circ},\;32.4{\pm}1.55^{\circ})$ was statisccally significant(P<0.01). 2. The average condylar guidance angle of the Vericheck was $27.0{\pm}3.43^{\circ}$. 3. The comparison of the right and left was not statistically significant in all group(P>0.05). 4. The comparison of pantograph and Vericheck was statistically significant in the right and left(P<0.001).

  • PDF