• 제목/요약/키워드: interocclusal record

검색결과 11건 처리시간 0.019초

운동의 기록방법에 관한 비교 연구 (A COMPARATIVE STUDY ON THE RECORDINGS OF MANDIBULAR MOVEMENT)

  • 신상용;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.125-146
    • /
    • 1990
  • The relationale for recording mandibular movement is to accurately adjust an articulator. Techniques to record mandibular movement include radiographic interpretation, extraoral tracing, and intraoral recording materials. This study was performed to compare the concylar guidance inclination and Bennett shift(immediate & progressive side shift)obtained by using an electronic pantograph, pantograph and wax interocclusal records in Korean. Ten adults who have normal occlusion and are free of TMJ dysfunction were selected and clutches were constructed. At first Pantronic survey was performed three times by using an kinematic hinge axis according to manufacturer's direction. Next pantographic survey was performed three times and the articulator was adjusted with each pantographic recording. And then maxillary cast was attached to the articulator with pantographic as a face-bow and the mandibular cast was mounted to the articulator with centric relation record. Three protrusive, three left lateral and three right lateral wax interocclusal records were taken on the subjects and the articulator was adjusted with each interocclusal record. Protrusive condylar inclination, lateral condylar inclination, immediate side shift and progressive side shift obtained by using electronic pantograph, pantograph and wax interocclusal record were compared and analized. The results were as follows; 1. The average left and right protrusive and orbiting condylar inclination($33.7^{\circ},\;37.1^{\circ},\;40.6^{\circ},\;43.5^{\circ}$) record with Pantronic was significantly greater than that recorded with other methods. 2. The average left and right protrusive and orbiting condylar inclination($24.8^{\circ},\;27.0^{\circ},\;31.4^{\circ},\;32.4^{\circ}$)recorded with wax interocclusal record was less than that of other methods. 3. The average left and right immediate side shift(0.57mm,0.44mm)recorded with wax interocclusal record was greater than that of other methods and the average left rigtht immmediate side shift(0.30mm,0.41mm)recorded with Pantronic was significantly greater than that recorded with pantograph(0.11mm,0.20mm). 4. The average variance of wax interocclusal was signivicantly higher than that of other methods.

  • PDF

수종 고무 교합인기 재료의 정확성에 관한 연구 (ACCURACY OF FOUR ELASTOMERIC INTEROCCLUSAL RECORDING MATERIALS)

  • 배정식
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.355-365
    • /
    • 1998
  • The purpose of this study is to evaluate the accuracy of four elastomeric interocclusal recording materials and the weight change according to different storage period (24 hours, 48hours, 7days) and different conditions (dry, wet). The techniques for establishing the intercuspal position were centic occlusion interocclusal record with four elastomeric interocclusal recording materials (Ramitec, Stat-BR, Blu-Mousse, Regisil) (experimental groups) and location of the cast in a position of maximum in-terdigitation using tactile and visual method(control group). To evaluate the accuracy of four elastomeric interocclusal recording materials, the quality of contacts between the mounted casts was compared with the results of an occlusal examination of the same subjects. The results were as follows : 1. The most accurate method of articulating study casts at the intercuspal position was by hand articulation and no significant differences in accuracy were observerd among the experimental groups. 2. In case of interocclusal records storaged in dry sealed plastic box, no significant differences in accuracy were observed among the experimental groups. 3. In case of interocclusal records storaged in water, there was significant inaccuracy in Ramitec group. 4. The biggest weight change was observed in Ramitec group in all storage conditions

  • PDF

A useful method of using the healing abutments for interocclusal records in implant overdenture: a case report

  • Choi, Hyunsuk;Kang, Sohee
    • Journal of Yeungnam Medical Science
    • /
    • 제39권4호
    • /
    • pp.341-343
    • /
    • 2022
  • To determine the vertical dimension and centric relation during the construction of implant overdentures, the record base and wax rim may need to be adjusted. The conventional method has several drawbacks, as it requires repeated tightening and loosening of the impression coping. Here, we report a useful and novel method for interocclusal records using the healing abutments in implant overdentures. Our case demonstrates that this method is easier and simpler and prevents gingival collapse.

구강스캐너 5종의 협측 악간관계 스캔 정확성 비교 연구 (Accuracy comparison of buccal bite scans by five intra-oral scanners)

  • 박지만;전진;허성주
    • 구강회복응용과학지
    • /
    • 제34권1호
    • /
    • pp.17-31
    • /
    • 2018
  • 목적: 이 연구의 목적은 다양한 구강 스캐너를 사용하여 협측 악간관계 스캔에 따른 상하악 악궁 관계의 정확성을 비교 평가하는 것이다. 연구 재료 및 방법: 정상 교합을 보이는 상하악 전악 모델을 5종(Cerec Omnicam, CS3500, iTero, Trios, TruDef)의 구강 스캐너로 제조사의 지시대로 스캔하였다. 폴리비닐실록산 교합 재료로 고정시킨 금속 지그를 이용하여 우측 구치부를 1, 2, 3, 4 mm 단계적으로 올린 후 좌측 협측 악간관계 스캔을 채득하였다. 두 데이터를 중첩하여 전체적인 삼차원 변이를 평가하였고, 교합 평면에 수직인 단면을 분석하여 교두간 거리의 양과 방향을 평가하였다. 결과: 중첩연구에서 Cerec Omnicam ($165.5{\mu}m$)이 가장 적은 변이를 보였고, CS3500 ($369.0{\mu}m$)이 가장 큰 변이를 보였으며(P < 0.01), 1 mm 보다 3, 4, 2 mm 이개 그룹에서 변이가 유의미하게 컸다(P < 0.01). 단면 연구에서는 Cerec Omnicam이 교두끼리의 거리가 가장 먼 변이를 보였고($-242.8{\mu}m$), CS3500이 가장 가까워지는 변이를 보였으며($312.5{\mu}m$), 다른 거상 높이 보다 3 mm 이개 그룹에서 유의하게 변이가 컸다(P < 0.01). 결론: 구강 스캐너 마다 협측 악간관계 스캔을 이용해 상하악 교합 관계를 재현하는 정확성이 달랐다.

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

A comparative study to measure the condylar guidance by the radiographic and clinical methods

  • Shreshta, Pragya;Jain, Veena;Bhalla, Ashu;Pruthi, Gunjan
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.153-157
    • /
    • 2012
  • PURPOSE. The study was conducted to compare the radiographic and clinical methods of measuring the horizontal condylar guidance (HCG) values. MATERIALS AND METHODS. The condylar guidance was measured using the radiographic (CT scan) and three clinical methods i.e. the wax protrusive records, Lucia jig record and intraoral central bearing device in 12 patients aged between 20-40 years irrespective of sex. The records were taken and transferred on the semi-adjustable articulator to record the HCG values. The CT scan was taken for 3D reconstruction of the mid facial region. Frankfort horizontal plane (FHP) and a line extending from the superior anterior most point on the glenoid fossa to the most convex point on the apex of articular eminence (AE) was marked on the CT scan. An angle between these two lines was measured on both right and left sides to obtain condylar inclination angle. Three interocclusal protrusive wax and jig records were taken and transferred to the semi adjustable articulator. Three readings were recorded on each side. Similarly the records were taken and transferred to the same articulator using the intra oral central bearing device to record the readings. RESULTS. The statistical analysis showed insignificant differences in the HCG values between the right and left sides [(P=.589 (CT), P=.928 (wax), P=.625 (jig), P=.886 (tracer)]. The clinical methods provided low Pearsons correlation values [(R = 0.423 (wax), R = 0.354 (jig), R = 0.265 (tracer)] for the right as well as the left sides when compared with the CT values. Among the clinical methods, jig and wax method showed strong level of association which is statistically significant while the intra-oral tracer showed weak association with the other two methods. CONCLUSION. The right and left HCG values were almost similar. The CT scan showed higher HCG values than the clinical methods and among the clinical methods, values obtained from all the methods were comparable.

광조사교합분석법을 이용한 머리 위치와 교합접촉면적의 관계 (Relation of head posture and occlusal contact area using photo occlusion analysis)

  • 김창환;고경호;허윤혁;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제35권2호
    • /
    • pp.90-97
    • /
    • 2019
  • 목적: 교합접촉면적에 관련된 이전의 연구들은 교합두께 수준이나 교합측정방법 상 부정확성이 한계로 지적되어 왔다. 본 연구의 목적은 머리 위치가 교합접촉면적에 미치는 영향을 광조사교합분석법을 이용하여 조사하는 것이다. 연구 재료 및 방법: 건전한 치열을 갖는 54명(남성 44명, 여성 10명, 23 - 33세)을 대상으로 시험을 진행하였다. 머리 위치와 교합접촉면적의 관계를 알아보기 위해 시험대상은 치과용 유닛체어에 세 가지 자세(누운 자세($0^{\circ}$), 기울인 자세($45^{\circ}$), 직립 자세($90^{\circ}$))로 하여 최대 교두간 접촉위를 이용하여 악간관계기록을 채득하였다. 광조사교합분석기($BiteEye^{(R)}$)를 이용하여 교합접촉면적을 분석하였다. SPSS 25.0을 이용하여 유의수준 95%에서 통계분석을 시행하였다. 결과:머리 위치는 교합접촉면적과 유의미한 영향이 없는 것으로 나타났다(P > 0.05). 결론: 머리 위치는 교합접촉면적에 유의미한 영향이 없으므로 교합관계가 안정적이라면 최대 교두간접촉위의 악간관계 기록 채득 시 환자의 자세는 변수가 되지 않으며 광조사교합분석기를 이용한 교합접촉면적의 측정은 재료적, 용이성 측면으로 유용하다고 할 수 있다.

전통적 방식과 CAD/CAM을 이용한 양악 총의치 수복 증례 (Fabrication of complete dentures by conventional method and CAD/CAM milling: A case report)

  • 정영철;이준석;홍성진;노관태;김형섭;배아란
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.296-303
    • /
    • 2019
  • 자연치아가 모두 상실되면, 저작이나 발음 등의 기능이 불가능할 뿐 아니라 심미성에 있어서도 노인성 안모를 가지게 되어 대단히 비심미적인 외모를 하게 된다. 총의치를 장착함으로써 저작기능도 회복되며, 총의치에 의한 구강 주위조직의 적절한 지지가 이루어짐으로써 심미성의 회복도 가능해진다. CAD/CAM을 이용한 의치는 저장된 데이터를 이용하여 언제든지 신속하게 의치의 재제작이 가능하고, 높은 강도와 밀도를 가지는 의치상이 장점이라고 할 수 있다. 본 증례에서는 최종의치 기공과정에서 악간관계채득 단계까지는 전통적 방식으로 진행한 후, 이후 최종의치 완성 전 기공과정을 전통적 방식과 CAD/CAM을 이용한 방식으로 나누어서 진행하였다. 이후 각각을 평가하여 환자가 만족하는 임상결과를 얻었기에 이를 보고하는 바이다.

Correlation between sagittal condylar guidance angles obtained using radiographic and protrusive occlusal record methods

  • Kwon, Oh-Kyun;Yang, Seung-Won;Kim, Jee-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.302-307
    • /
    • 2017
  • PURPOSE. This study compared the SCGAs measured in three types of radiographic images (panoramic, CBCT panoramic-section, and CBCT cross-section images) with values measured using the protrusive occlusal record. MATERIALS AND METHODS. SCGAs were measured in 20 patients on a semi-adjustable articulator using the protrusive interocclusal record. Panoramic and CBCT images were obtained. SCGAs were measured on CBCT images in panoramic and cross sections. In all of the radiographic images, SCGAs were measured using the Frankfort horizontal reference line and the mean curvature line. The most-superior and most-inferior points of the curvatures were identified to determine the mean curvature line. Each measurement was performed twice by two operators independently. The data were analyzed by the t-test, Pearson's correlation test, and Cronbach's ${\alpha}$ using SPSS (${\alpha}=.05$). RESULTS. The mean right and left SCGAs were as follows: protrusive occlusal record (30.1 and 30.2 degrees, respectively), panoramic (38.9 and 38.7 degrees), CBCT panoramic sections (35.4 and 36.8 degrees), and CBCT cross sections (35.3 and 36.1 degrees). The SCGAs differed significantly among the groups. The Pearson coefficients for the correlations with the protrusive occlusal record measurements on the left and right sides were as follows: panoramic (0.834 and 0.791, respectively), CBCT panoramic-section (0.918 and 0.837), and CBCT cross-section (0.918 and 0.845) images. CONCLUSION. Strong correlations were found between SCGAs obtained using radiographic images and the protrusive occlusal record.

측정방법에 따른 시상과로 경사각의 차이에 관한 연구 (A STUDY ON THE DIFFERENCE OF THE SAGITTAL CONDYLAR GUIDANCES BY MEASURING METHODS)

  • 유진영;계기성
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.77-86
    • /
    • 1993
  • The purpose of this study was to compare the sagittal condylar guidance obtained by the graphic method(pantographic tracing) with that produced by the positional method(check-bite). Ten adults who had normal occlusion and were free of TMJ dysfunction were selected, and the clutches were constructed. At first pantographic survey was performed and the articulator was adjusted with each pantographic recording. And then three protrusive check-bite were taken on the subjects using the polyether$(Lamitec^{(R)})$ on the buccal side of the posterior teeth without the interocclusal record method and the vericheck method was performed with each protrusive check-bite. Sagittal condylar guidances obtained by using the pantograph and Vericheck were compared and analyzed statistically. The results were as follows: 1. The average condylar guidance ankle at 4mm and 7mm from centric relation point on the pantograph $(35.9{\pm}1.10^{\circ},\;32.4{\pm}1.55^{\circ})$ was statisccally significant(P<0.01). 2. The average condylar guidance angle of the Vericheck was $27.0{\pm}3.43^{\circ}$. 3. The comparison of the right and left was not statistically significant in all group(P>0.05). 4. The comparison of pantograph and Vericheck was statistically significant in the right and left(P<0.001).

  • PDF